Senko SI-301 Fixed Gas Detector
- IP65 explosion-proof rated structure
- Cartridge-type sensor for easy maintenance
- Operating voltage: DC 24V or PoE 36V~57V
- Large LCD for gas concentration and flow rate
- Sample distance: up to 30m input/exhaust
- RS485, TCP Ethernet, and Bluetooth control
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Buy Senko SI-301
The Senko SI-301 is a sampling-type fixed gas detector engineered to monitor and detect hazardous gases in real time, thereby enhancing safety across various industrial settings. Its advanced design and user-friendly features make it a reliable choice for continuous gas monitoring.
Key Features
The Senko SI-301 offers several notable features that contribute to its effectiveness:
- Explosion-Proof Structure: Designed with an IP65-rated explosion-proof enclosure, the SI-301 ensures safe operation in hazardous environments.
- Cartridge-Type Sensor: The detector utilizes a cartridge-type sensor, facilitating easy maintenance and quick sensor replacements.
- Built-in Flow Control: Equipped with an internal flow control function, it maintains consistent sampling for accurate gas detection.
- Large LCD Display: The device features a large LCD that provides clear digital indications of gas concentrations and flow rates, enhancing user readability.
- Multiple Control Options: Users can configure the SI-301 through various interfaces, including RS485, TCP Ethernet, and Bluetooth, offering flexibility in integration and control.
Applications
The versatility of the Senko SI-301 makes it suitable for a wide range of industrial applications:
- Semiconductor Industry: Monitors gases used in semiconductor manufacturing processes to prevent accidents related to suffocation, intoxication, and explosions.
- Sewage Treatment Plants: Detects hazardous gases like hydrogen sulfide and methane, ensuring the safety of personnel and infrastructure.
- Mining Operations: Continuous monitoring of combustible and toxic gases is crucial for preventing mine-related accidents.
- Petrochemical Plants: Assists in detecting gas leaks and preventing potential fire or explosion hazards in petrochemical processing facilities.
- Steelworks: Monitors for the presence of harmful gases during steel production processes, safeguarding workers and equipment.
- Power Supply Operations: Ensures the detection of gas leaks in power generation and distribution environments, maintaining operational safety.
Connectivity and Integration
The Senko SI-301 is designed for seamless integration into existing safety systems:
- Analog and Digital Outputs: It transmits real-time gas concentration data via a 4-20 mA output and supports RS485 communication, facilitating easy integration with various control systems.
- Relay Configurations: The device includes three internal relays that can be configured for specific control actions, enhancing its adaptability to different safety protocols.
Maintenance and User Convenience
Designed with user convenience in mind, the SI-301 simplifies maintenance procedures:
- Easy Sensor Replacement: The cartridge-type sensor design allows for quick and straightforward sensor replacements, reducing downtime.
- User-Friendly Interface: The large LCD and intuitive control buttons make it easy for users to operate and configure the device as needed.
Senko SI-301 Specifications
The Senko SI-301 has a flow rate ranging from 100 to 1,000 ml, with a normal rate of 301 to 500 ml per minute.
| Size | 194mm(W) X 152.4mm(D) X 136mm(H) |
| Weight | 4Kg |
| Operating voltage | DC : 24V ± 10% |
| PoE : 36V~57V (Typical : 48V) | |
| Flow rate | 100 ~ 1,000 ml (Normal 301 ~ 500ml / min) |
| Power consumption | Approximately 5.0W |
| Measurement display | FND, gas concentration, flow rate, alarm, device faulty |
| Relay | Low Alarm, High Alarm, Fault Alarm |
| Analog Output signal | 4-20mA |
| Digital communication | RS-485, TCP Ethernet |
| Sampling distance | Length of input gas tube: up to 30m (FEP tube) |
| Length of exhaust gas tube: up to 30m (FEP tube) | |
| Input/Output tube | 1/4” Teflon tube |
| Operating temperature | -40°C ~ 55°C |
| Certification | KCs: Ex db IIC T6 Gb |
| IP | IP 65 (KS C IEC60529:2013) |
| Control/Set | 4 Button & RS485 & Ethernet & Bluetooth |
| The warranty period of the device | 2 years |
| Warranty period of sensor cartridge | 1 year |
| Remote interface | Ethernet, RS-485, HART (Option) |
| Wiring | 4 to 20mA / DC power / Relay : up to 14 AWG |
| Pressure range | 90 to 110KPa |
| Maximum sample flow | Max. 1,000 ml |
| Maximum sample pressure | 3KPa |
| Gas | Sensor | Range | A1 | A2 | Resolution |
| Oxygen (O₂) | Electrochemical | 0~30%Vol | 19.0%vol | 23.0%vol | 0.1%vol |
| Carbon Monoxide (CO) | Electrochemical | 0~500ppm | 30ppm | 60ppm | 1ppm |
| Sulfur Dioxide (SO₂) | Electrochemical | 0~20ppm | 2ppm | 5ppm | 0.1ppm |
| Hydrogen (H₂) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Hydrogen (H₂) | Electrochemical | 0~1000ppm | 100ppm | 500ppm | within 5ppm |
| Hydrogen Sulfide (H₂S) | Electrochemical | 0~500ppm | 10ppm | 15ppm | 1ppm |
| Combustible | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Combustible | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Ammonia (NH₃) | Electrochemical | 0~100ppm | 25ppm | 35ppm | 1ppm |
| Acetylene (C₂H₂) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Ethanol (C₂H₆O) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Toluene (C₇H₈) | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Toluene (C₇H₈) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Methane (CH₄) | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Methane (CH₄) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Chlorine (Cl₂) | Electrochemical | 0~5ppm | 0.5ppm | 1.0ppm | 0.1ppm |
| Chlorine (Cl₂) | Electrochemical | 0~20ppm | 0.5ppm | 1.0ppm | 0.1ppm |
| Carbon Dioxide (CO₂) | IR | 0~2000ppm | 1000ppm | 1500ppm | 3ppm |
| Carbon Dioxide (CO₂) | IR | 0~5000ppm | 3010ppm | 5000ppm | 8ppm |
| Carbon Dioxide (CO₂) | IR | 0~5%Vol | 0.5%vol | 3%vol | 0.1%vol |
| Hydrogen Chloride (HCl) | Electrochemical | 0~10ppm | 1ppm | 2ppm | 0.1ppm |
| VOC | PID | 0~1000ppm | 50ppm | 100ppm | within 3ppm |
| Xylene (C₈H₁₀) | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Hydrogen Peroxide (H₂O₂) | Electrochemical | 0~10ppm | 1ppm | 3ppm | 0.1ppm |
| Nitrogen Dioxide (NO₂) | Electrochemical | 0~20ppm | 3ppm | 5ppm | 0.1ppm |
| Ethylene Oxide (C₂H₄O) | Electrochemical | 0~30ppm | 1ppm | 2ppm | 0.1ppm |
| Ethylene (C₂H₄) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Nitrogen Monoxide (NO) | Electrochemical | 0~100ppm | 25ppm | 50ppm | 1ppm |
| Hydrogen Fluoride (HF) | Electrochemical | 0~5ppm | 0.5ppm | 1ppm | 0.1ppm |
Buy the Senko SI-301 Fixed Gas Detector for an effective solution in real-time gas monitoring across multiple industries. Its strong features, application versatility, and user-friendly design make it an essential tool for ensuring safety in environments with potential gas hazards.
Specifications
| Size | 194mm(W) X 152.4mm(D) X 136mm(H) |
| Weight | 4Kg |
| Operating voltage | DC : 24V ± 10% |
| PoE : 36V~57V (Typical : 48V) | |
| Flow rate | 100 ~ 1,000 ml (Normal 301 ~ 500ml / min) |
| Power consumption | Approximately 5.0W |
| Measurement display | FND, gas concentration, flow rate, alarm, device faulty |
| Relay | Low Alarm, High Alarm, Fault Alarm |
| Analog Output signal | 4-20mA |
| Digital communication | RS-485, TCP Ethernet |
| Sampling distance | Length of input gas tube: up to 30m (FEP tube) |
| Length of exhaust gas tube: up to 30m (FEP tube) | |
| Input/Output tube | 1/4” Teflon tube |
| Operating temperature | -40°C ~ 55°C |
| Certification | KCs: Ex db IIC T6 Gb |
| IP | IP 65 (KS C IEC60529:2013) |
| Control/Set | 4 Button & RS485 & Ethernet & Bluetooth |
| Warranty period of the device | 2 years |
| Warranty period of sensor cartridge | 1 year |
| Remote interface | Ethernet, RS-485, HART (Option) |
| Wiring | 4 to 20mA / DC power / Relay: up to 14 AWG |
| Pressure range | 90 to 110KPa |
| Maximum sample flow | Max. 1,000 ml |
| Maximum sample pressure | 3KPa |
| Gas | Sensor | Range | A1 | A2 | Resolution |
| Oxygen (O₂) | Electrochemical | 0~30%Vol | 19.0%vol | 23.0%vol | 0.1%vol |
| Carbon Monoxide (CO) | Electrochemical | 0~500ppm | 30ppm | 60ppm | 1ppm |
| Sulfur Dioxide (SO₂) | Electrochemical | 0~20ppm | 2ppm | 5ppm | 0.1ppm |
| Hydrogen (H₂) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Hydrogen (H₂) | Electrochemical | 0~1000ppm | 100ppm | 500ppm | within 5ppm |
| Hydrogen Sulfide (H₂S) | Electrochemical | 0~500ppm | 10ppm | 15ppm | 1ppm |
| Combustible | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Combustible | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Ammonia (NH₃) | Electrochemical | 0~100ppm | 25ppm | 35ppm | 1ppm |
| Acetylene (C₂H₂) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Ethanol (C₂H₆O) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Toluene (C₇H₈) | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Toluene (C₇H₈) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Methane (CH₄) | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Methane (CH₄) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Chlorine (Cl₂) | Electrochemical | 0~5ppm | 0.5ppm | 1.0ppm | 0.1ppm |
| Chlorine (Cl₂) | Electrochemical | 0~20ppm | 0.5ppm | 1.0ppm | 0.1ppm |
| Carbon Dioxide (CO₂) | IR | 0~2000ppm | 1000ppm | 1500ppm | 3ppm |
| Carbon Dioxide (CO₂) | IR | 0~5000ppm | 3010ppm | 5000ppm | 8ppm |
| Carbon Dioxide (CO₂) | IR | 0~5%Vol | 0.5%vol | 3%vol | 0.1%vol |
| Hydrogen Chloride (HCl) | Electrochemical | 0~10ppm | 1ppm | 2ppm | 0.1ppm |
| VOC | PID | 0~1000ppm | 50ppm | 100ppm | within 3ppm |
| Xylene (C₈H₁₀) | IR | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Hydrogen Peroxide (H₂O₂) | Electrochemical | 0~10ppm | 1ppm | 3ppm | 0.1ppm |
| Nitrogen Dioxide (NO₂) | Electrochemical | 0~20ppm | 3ppm | 5ppm | 0.1ppm |
| Ethylene Oxide (C₂H₄O) | Electrochemical | 0~30ppm | 1ppm | 2ppm | 0.1ppm |
| Ethylene (C₂H₄) | Catalytic | 0~100%LEL | 15%LEL | 50%LEL | 1%LEL |
| Nitrogen Monoxide (NO) | Electrochemical | 0~100ppm | 25ppm | 50ppm | 1ppm |
| Hydrogen Fluoride (HF) | Electrochemical | 0~5ppm | 0.5ppm | 1ppm | 0.1ppm |