Fluke 1746/15/EUS Power Quality Logger with 60 cm 1,500A iFlex, EUS version
- 60 cm 1,500A iFlex current probe included
- EUS version for specific regional compliance
- 16-bit resolution at 10.24 kHz sampling
- Measures harmonics up to 50th order
- Internal flash memory for long-term data logging
- Li-ion battery with 4-hour runtime
- Supports 1-phase to 3-phase Aron/Blondel configurations
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
Memory vs sessions vs events (Fluke 1740 series): Internal flash typically stores about 20 logging sessions of 4 weeks at 1-minute intervals. Event capacity (e.g., dips/swells/inrush) is separate from session duration—longer sessions reduce remaining room for high event counts. Warm-up / low-temperature notes follow Fluke operating specs (instrument vs battery limits).
The Fluke 1746/15/EUS Power Quality Logger is a sophisticated instrument designed for engineers and technicians who need to analyze complex electrical networks. This EUS version logger captures detailed power quality data, recording voltage, current, harmonics, and flicker across multiple circuit configurations. With its flexible iFlex current probe, it provides accurate measurements without breaking into circuits, making it ideal for field surveys and permanent installation monitoring. The device supports a wide range of power system types, from single-phase split phase to complex three-phase delta and wye arrangements, ensuring comprehensive coverage for diverse industrial applications.
Fluke 1746/15/EUS Key Features
This Power Quality Logger delivers high-resolution data acquisition with 16-bit synchronous sampling at 10.24 kHz, synchronized to the mains frequency for precise analysis. The internal flash memory stores typical 20 logging sessions of four weeks at one-minute intervals, capturing up to 500 events per session. Key features include measurement of individual harmonics from the 2nd to the 50th order, interharmonics analysis, and total harmonic distortion calculations based on 50 voltage harmonics. The logger also captures voltage events such as dips, swells, and interruptions, as well as current inrush events, providing a complete picture of power quality issues.
- 16-bit resolution at 10.24 kHz sampling frequency
- Measures harmonics up to the 50th order
- Captures interharmonics from 1st to 50th order
- Records voltage events: dips, swells, and interruptions
- Records current inrush events for load studies
- Supports current transformer and direct input methods
- Internal memory for 20 sessions of four weeks duration
- iFlex 60 cm, 1,500A flexible current probe included
Who Needs the Fluke 1746/15/EUS?
Electrical engineers and maintenance technicians will find the Fluke 1746/15/EUS indispensable for troubleshooting power quality issues in industrial and commercial facilities. Energy managers can utilize the device to monitor energy consumption patterns and identify opportunities for efficiency improvements. Building services teams rely on this logger to ensure equipment operates within acceptable power quality limits, reducing the risk of downtime and equipment damage. Procurement buyers seeking a reliable, data-rich logger for compliance and audit purposes will appreciate the comprehensive data storage and reporting capabilities of the EUS version.
The versatility of the 1746/15/EUS makes it suitable for a broad spectrum of applications, from simple single-phase load studies to complex three-phase power system analysis. Engineers working on renewable energy installations can monitor harmonic distortion introduced by inverters, while facility managers can verify that electrical distribution systems meet local regulatory standards. The logger’s ability to capture long-term trends aids in predictive maintenance strategies, allowing teams to address potential issues before they lead to costly failures.
Fluke 1746/15/EUS Applications
In manufacturing plants, the Fluke 1746/15/EUS is used to monitor the power quality of heavy machinery, identifying sources of harmonic distortion that can cause overheating and premature failure of motors and drives. Data centers rely on the logger to ensure a stable power supply, capturing events that could impact critical IT equipment. In the renewable energy sector, the device assesses the quality of power fed back into the grid from solar or wind installations, ensuring compliance with grid interconnection standards. Utility companies use the logger for field surveys to analyze distribution system performance and plan infrastructure upgrades based on real-world data.
Commercial buildings benefit from the Fluke 1746/15/EUS by monitoring the power factor and demand charges, enabling facility managers to optimize capacitor bank switching and reduce electricity costs. The logger is also effective in diagnosing power quality issues in HVAC systems, where variable frequency drives can introduce significant electrical noise. By providing detailed harmonic analysis, the tool helps engineers pinpoint the exact source of interference, facilitating targeted mitigation strategies.
Why Buy Fluke 1746/15/EUS from Mohammad Mahdi Electronics?
Mohammad Mahdi Electronics is the trusted source for genuine Fluke testing and measurement equipment in the UAE. When you purchase the Fluke 1746/15/EUS Power Quality Logger from MME, you receive a brand-new unit with the original manufacturer’s warranty, ensuring peace of mind for your critical measurements. Our team of experts is available to provide technical guidance, helping you select the right logger configuration and iFlex probe length for your specific application needs. We prioritize fast shipping and secure packaging to ensure your instrument arrives ready for immediate deployment.
Choosing Mohammad Mahdi Electronics means accessing authentic Fluke products with the full manufacturer’s support and calibration certificates. We understand the importance of accurate power quality data for your operations, which is why we stock only genuine instruments designed to meet the highest industry standards. Our customer service team is committed to providing a seamless purchasing experience, from product selection to after-sales support, with dedicated after-sales support in the region.
Electrical Specifications
- Voltage range: 100 V to 500 V using safety plug input when powering from the measurement circuit
- 100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7)
- Power consumption: Maximum 50 VA (max. 15 VA when powered using MA-C8 adapter)
- Efficiency: ≥ 68.2% (in accordance with energy efficiency regulations)
- Maximum no-load consumption: < 0.3 W only when powered using IEC 60320 input
- Mains power frequency: 50/60 Hz ±15%
- Battery: Li-ion 3.7 V, 9.25 Wh, customer-replaceable
- On-battery runtime: Typically 4 hours
- Charging time: < 6 hours
Data Acquisition
- Resolution: 16-bit synchronous sampling
- Sampling frequency: 10.24 kHz at 50/60 Hz, synchronized to mains frequency
- Input signal frequency: 50/60 Hz (42.5 to 69 Hz)
- Circuit types: 1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)
- Data storage: Internal flash memory (not user replaceable)
- Memory size: Typical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events
Basic Interval
- Measured parameters: Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
- Averaging interval: User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
- Averaging time min/max values: Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms)
Demand Interval (Energy Meter Mode)
- Measured parameters: Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
- Interval: User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Power Quality Measurements
- Measured parameter: Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation
- Averaging interval: 10 min for all parameters 2 hrs (long term Flicker PLT) 150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT)
- Individual harmonics: 2nd to 50th harmonic
- Grouping according to IEC 61000-4-7 user configurable: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only
- Interharmonics: 1st to the 50th interharmonic
- Total harmonic distortion: Calculated on 50 voltage harmonics
- Events: Voltage: dips, swells, interruptions, current: inrush current 1748: mains signaling, transients (low frequency)
Stock the Fluke 1746/15/EUS Power Quality Logger from MME today and ensure your power systems operate at peak efficiency. Our knowledgeable team is ready to assist you with selecting the right instrumentation for your specific electrical analysis requirements.
Fluke 1746/15/EUS Specifications
| Electrical Specifications | |
| Power Supply | |
| Voltage range | 100 V to 500 V using safety plug input when powering from the measurement circuit |
| 100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7) | |
| Power consumption | Maximum 50 VA (max. 15 VA when powered using MA-C8 adapter) |
| Efficiency | ≥ 68.2% (in accordance with energy efficiency regulations) |
| Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input |
| Mains power frequency | 50/60 Hz ±15% |
| Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
| On-battery runtime | Typically 4 hours |
| Charging time | < 6 hours |
| Data Acquisition | |
| Resolution | 16-bit synchronous sampling |
| Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency |
| Input signal frequency | 50/60 Hz (42.5 to 69 Hz) |
| Circuit types | 1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies) |
| Data storage | Internal flash memory (not user replaceable) |
| Memory size | Typical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events |
| Basic Interval | |
| Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
| Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms) |
| Demand Interval (Energy Meter Mode) | |
| Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |
| Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
| Power Quality Measurements | |
| Measured parameter | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation |
| Averaging interval | 10 min for all parameters 2 hrs (long term Flicker PLT) 150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT) |
| Individual harmonics | 2nd to 50th harmonic Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only |
| Interharmonics | 1st to the 50th interharmonic |
| Total harmonic distortion | Calculated on 50 voltage harmonics |
| Events | Voltage: dips, swells, interruptions, current: inrush current 1748: mains signaling, transients (low frequency) |
| Triggered recordings | RMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1/2 according to IEC 61000-4-30) |
| Waveform of voltage and current up to 200 ms, 10/12 cycles | |
| Mains signaling: 10/12 cycle RMS recording of the configured frequencies up to 120s | |
| Inrush | RMS profile based on 1/2 cycle RMS steady state triggering |
| Flicker | In accordance with IEC 61000-4-15 and IEEE 1453 |
| Mains signaling | Two user defined frequencies up to 3 kHz |
| PQ Health | Summarizes power quality measurements in one table. Detailed data available for each parameter |
| EN 50160 | Compliance with standard |
| Programmable PQ limits | Enables user defined limits for local standards compliance |
| Standards Compliance | |
| Harmonics | IEC 61000-4-7: Class 1 |
| IEEE 519 (short time and very short time harmonics) | |
| Power quality | IEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device) |
| Power | IEEE 1459 |
| Power quality compliance | EN 50160 |
| Safety | General: IEC 61010-1: Pollution Degree 2 |
| Measurement: IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V | |
| Power Supply: Overvoltage Category IV, Pollution Degree 2 | |
| Li-ion Battery: IEC 62133 | |
| Interfaces | |
| USB-A | File transfer via USB flash drive, firmware updates, max. supply current: 120 mA |
| Wi-Fi (free with product registration) | File transfer and remote control via direct connection or Wi-Fi infrastructure |
| Bluetooth | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or Wi-Fi/BLE adapter, check for availability) |
| USB-mini | Data download device to PC |
| Voltage Inputs | |
| Number of inputs | 4 (3 phases referenced to neutral) |
| Maximum input voltage | 1000 Vrms, CF 1.7 |
| Input impedance | 10 MΩ |
| Bandwidth | 42.5 Hz to 3.5 kHz |
| Scaling | 1:1 and variable |
| Measurement category | 1000 V CAT III/600 V CAT IV |
| Current Inputs | |
| Number of inputs | 4 (3 phases and neutral), mode selected automatically for attached sensor |
| Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 |
| Rogowski coil input: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4 all at nominal probe range | |
| Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 IP 24 |
| 3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 IP 24 | |
| 6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 IP 36 | |
| 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |
| Bandwidth | 42.5 Hz – 3.5 kHz |
| Scaling | 1:1 and variable |
| Auxiliary Inputs | |
| Number of inputs | 2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously) |
| Input range | 0 to ± 10 V dc, or 0 to ± 1000 V dc (with optional adapter), 1 reading/s |
| Scale factor | Format: mx + b (gain and offset) user configurable |
| Displayed units | User configurable (7 characters, for example, °C, psi, or m/s) |
| Wireless Bluetooth connection (check for availability) | |
| Number of inputs | 2 |
| Supported modules | Fluke Connect® 3000 series |
| Acquisition | 1 reading/s |
| Environmental Specifications | |
| Operating temperature | -25 °C to +50 °C (-13 °F to 122 °F)1 |
| Storage temperature | Without battery: -25 °C to +60 °C (-13 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F) |
| Operating humidity | IEC 60721-3-3: 3K6: |
| -25 °C to +30 °C (-13 °F to +86 °F): ≤ 100 % | |
| 40 °C (104 °F): 55 % | |
| 50 °C (122 °F): 35 % | |
| Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
| Storage altitude | 12,000 m |
| Enclosure | IEC 60529: IP50 |
| IEC 60529: IP65 with IP65 rated voltage connector | |
| Vibration | IEC 60721-3-3 / 3M2 |
| Electromagnetic compatibility (EMC) | EN 61326-1: Industrial CISPR 11: Group 1, Class A |
| IEC 61000-6-5 Power station environment | |
| Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |
| USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |
| General Specifications | |
| Warranty | Two-years (battery not included) |
| Accessories: one-year | |
| Calibration cycle: two-years | |
| Dimensions | 23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in) |
| Weight | Instrument: 1 kg (2.2 lb) |
| Tamper protection | Accept securing cables (max. Φ 6mm) |
| 1Warm up the product to -10 °C (+14 °F) before you power the unit on | |
| i17XX-FLEX1.5KIP Flexible Current Probe Specifications | |
| Measuring range | 1 to 150 A ac/10 to 1500 A ac |
| Probe cable length | 610 mm (24 in) |
| Probe cable diameter | 7.5 mm (0.3 in) |
| Weight | 170 g (0.38 lb) |
| Minimum bending radius | 38 mm (1.5 in) |
| Nondestructive current | 100 kA (50/60 Hz) |
| Temperature coefficient over operating temperature range |
0.05 % of reading/°C (0.028 % of reading/°F) |
| Working voltage | 1000 V CAT III, 600 V CAT IV |
| Output cable length | 2.0 m (6.5 ft) |
| Probe cable material | TPR |
| Weight | 115 g |
| Probe cable material | TPR |
| Coupling material | POM + ABS/PC |
| Output cable | TPR/PVC |
| Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) |
| Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) |
| Relative humidity, operating | 15% to 85% non-condensing |
| IP rating | IEC 60529: IP65 |
| Warranty | One-year |
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.