Megger LT300-HIGH CURRENT LOOP TESTER

The Megger LT300 High Current Loop Tester is ideal for CAT IV 300V applications, providing high current loop testing over a wide range of frequencies and voltages. With a resolution of 0.01Ω on the 20Ω range and 0.1Ω on the 200Ω range, the LT300 delivers results quickly, accurately, and steadily. Installations without RCDs are intended for the LT300 loop impedance tester. An enhanced range of applications, such as single phase CAT IV 300V phase to earth and CAT IV 550V phase to phase, are made possible by the broad frequency and voltage ranges. Testing will start automatically as soon as the Megger LT300 loop tester is connected to the supply, and repeat testing is available with a single button press.

For more information on other models, such as the UNI-T UT582+ , click on the relevant link

Megger LT300-HIGH CURRENT LOOP TESTER specifications:

  • Voltage Measurement Range:0V to 550V (400V @ 16Hz)
  • Voltage Accuracy:±5% ± 2V
  •  Loop Test Operating Frequencies :16Hz – 15Hz to 18Hz, 29Hz to 337Hz
    50/60Hz – 40Hz to 70Hz, 125Hz, 100Hz to 142Hz
    400Hz – 260Hz to 498Hz
  • Test Currents:550V: 20Ω – 27A, 200Ω – 2.7A
    230V: 12Ω – 12A, 200Ω – 1.2A
    115V: 20Ω – 6A, 200Ω – 0.6A
    50V: 20Ω – 3A, 200Ω – 0.3A
  • Loop Test Accuracy:0 to 19.99Ω (20Ω range) – ±5% ±0.03Ω
    0 to 199.9Ω (200Ω range) – ±5% ± 0.5Ω
  • Operating Temperature:-10 to 60°C
  • Storage Temperature:-25 to 70°C
  • Humidity:90% RH @ 40°C
  • Battery:8 x AA (LR6) Alkaline or NiMH Rechargable Cells
  • EN61557:Complies with the following parts of EN61577:
    Electrical Safety in Low Voltage Systems up to 1000V AC
    and 1500V DC, Equipment for Testing, Measuring or
    Montioring of Protective Measures:
    Part 1 – General Requirements
    Part 3 – Loop Resistance
  • Safety:Meets the requirements of IEC61010-1 300V CAT IV
    Phase to Earth or 550V Phase to Phase (400V@16Hz)
Data Sheet

Data Sheet

Data Sheet

Specifications

Specifications

SPECIFICATIONS
Voltage Measurement
Voltage Range 0 V to 550 V (400 V @ 16 Hz)
Accuracy ±5% ±2 V
Loop Test Operating Frequencies
16 Hz 15 Hz to 18 Hz
33 Hz 29 Hz to 37 Hz
50/60 Hz 40 Hz to 70 Hz
125 Hz 100 Hz to 142 Hz
400 Hz 260 Hz to 498 Hz
Test Currents
Test Voltage 20 Ω Range / 200 Ω Range
550 V 27 A / 2.7 A
230 V 12 A / 1.2 A
115 V 6 A / 0.6 A
50 V 3 A / 0.3 A
Loop Test Accuracy
Loop Resistance (20 Ω Range) 0 – 19.99 Ω ±5% ±0.03 Ω
Loop Resistance (200 Ω Range) 0 – 199.9 Ω ±5% ±0.5 Ω
Environmental
Operating Temperature −10°C to +60°C
Storage Temperature −25°C to +70°C
Humidity 90% RH @ +40°C
Maximum Altitude 2000 m
Dust and Water Protection IP54
Battery 8 × AA (LR6) alkaline or NiMH rechargeable cells
Safety
Standard IEC61010-1, 300 V CAT IV (phase to earth) or 550 V (phase to phase, 400 V @ 16 Hz)
EN61557 Compliance Part 1 – General Requirements
Part 3 – Loop Resistance
EMC
Standard In accordance with IEC61326-1
Physical
Weight 980 g (2.16 lb)
Dimensions 203 × 148 × 78 mm (8 × 5.8 × 3 in)