Megger MIT400/2 series-Insulation Tester
The Megger MIT400/2 series-CAT IV INSULATION TESTERS are designed not just for Electrical and Industrial, but with an exceptionally wide range of applications from electrical installations, cable testing, motor testing.
MME Shopping Event
Hurry and get discounts on Most of MME Products up to 20%
Call for Price
Megger MIT400/2 series-CAT IV INSULATION TESTER
The Megger MIT400/2 series represents a significant advancement in insulation and continuity testing technology, designed to meet the rigorous demands of a wide array of applications including electrical installations, cable testing, motor testing, automotive diagnostics, ESD safety, panel building, avionics, and routine maintenance tasks. This series is a pivotal update from the earlier MIT400 instruments, featuring several innovative enhancements that cater to both general and specialized testing needs.
Key to the MIT400/2 series is its ability to perform insulation testing up to 1000 V and a 200 GΩ range, setting a new standard in the industry. It introduces a stabilized insulation test voltage, which limits overvoltage to just 2%, a substantial reduction from the typical 10 to 20% found in other models. This precise control ensures safer, more accurate measurements. The series also offers a unique single-range continuity testing feature that spans from 0.01 Ω to 1 MΩ, facilitating quicker and more efficient testing.
Another significant upgrade is the variable insulation test voltage, which can be adjusted from 100V to 1000V depending on the model, and is customizable in 10 V increments. This allows for application-specific voltages that are not available in standard ranges, providing unparalleled flexibility in testing different types of electrical equipment and installations.
Megger MIT400/2 series-CAT IV INSULATION TESTER Specifications:
- Display range : Analogue:1 GΩ full scale
- Resolution : 0.1 kΩ.
- Short circuit/charge current : 2 mA +0% -50% to EN 61557-2 (2007)
- Open circuit voltage insulation : -0% +2% ± 2V.
- Test current : 1 mA at min. pass value of insulation to a maximum of 2 mA max.
- Leakage (not MIT400/2) : 10% ±3 digits.
- Voltage : 3% ±3 digits ±0.5% of rated voltage
- Timer control (not MIT400/2)60 : second countdown timer.
- Note : Above specifications only apply when high quality silicone leads are being used.
- Continuity:Continuity measurement : 0.01 Ω to 1000 kΩ.
- Continuity accuracy : ± 3% ± 2 digits (0 to 100 Ω )±5% ±2 digits (100 to 500kΩ)(500kΩ to 1MΩ unspecified)Service Error: BS EN 61557-4 (2007) – ± 2.0%, 0.1 Ω – 2 Ω ± 6.8%.
- Open circuit voltage : 5 V ± 1 V
- Test current : 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω).
- Polarity (not MIT400/2) : Single polarity (Default) / Dual polarity (configurable on setup).
- Lead resistance : Null up to 9.00 Ω.
- Voltage:
- Voltage range : AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz)DC: 0 to 600 V.
- Volt range accuracy : AC: ±2% ±1 digitDC: ±2% ±2 digitService Error: BS EN 61557-1 (2007) – ± 2.0% ± 2d, 0 V – 300 V AC/DC ± 5.1%.
- Wave form : Unspecified range:0 – 10 mV (15 to 400 Hz) For non-sinusoidal waveforms additional specifications applyNon-sinusoidal waveforms:±3% ± 2 digits >100 mV to 600 V TRMS±8% ± 2 digits 10 mV to 100 mV TRMS.
- Frequency: (not MIT400/2)
- Frequency measurement range : 15 Hz – 400 Hz.
- Frequency measurement accuracy : ±0.5% ± 1digit (100 Hz to 400 Hz unspecified)
- Capacitance measurement:MIT420/2, MIT430/2MIT420/2, MIT430/2.
- Capacitance measurement1 nF to 10 μFCapacitance measurement.
- accuracy : ± 5.0% ± 2 digits (0.1 nF – 1 nF unspecified).
- Storage Megger MIT400/2 series:
- Result storage (MIT420/2 and MIT430/2):
- Storage capacity>1000 test results
- Data download (MIT430/2 only) : Bluetooth® wirelessBluetooth® Class II.
- Range : up to 10 m.
- Power supply : 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline6 x 1.2 V NiMH rechargeable cells may be used.
- Battery life : 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ.
- Charger (Optional):12-15 V dc (accessory interface).
- Dimensions : Instrument 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in).
- Weight : 600 g (MIT400/2), (1.32 lb).
1 review for Megger MIT400/2 series-Insulation Tester
Clear filtersYou must be logged in to post a review.
Brand
Megger
Megger
Megger since 1889 is a leading global premium manufacturer of measurement and testing technology. Megger top priority has always been to make your everyday work easier and safer. As such, insulation testers, micro-ohmmeters, and multimeters are among the long line of Megger inventions, making this brand one of the pioneers in the electrical industry. Megger products combine many years of experience and the valued feedback from our global users with the inventiveness and conscientiousness of our product developers. In Germany, we manufacture at three sites, Aachen, and Baunach near Bamberg and Radeburg near Dresden. Other manufacturing locations are based in Sweden, England, and America.
Specifications
Technical Specifications for Megger MIT400/2 Series | |
---|---|
Display Range | Analog: 1 GΩ full scale |
Resolution | 0.1 kΩ |
Short Circuit/Charge Current | 2 mA +0% -50% to EN 61557-2 (2007) |
Open Circuit Voltage Insulation | -0% +2% ± 2V |
Test Current | 1 mA at min. pass value of insulation to a maximum of 2 mA max. |
Continuity Measurement | 0.01 Ω to 1000 kΩ |
Continuity Accuracy | ± 3% ± 2 digits (0 to 100 Ω) ±5% ±2 digits (100 to 500kΩ) (500kΩ to 1MΩ unspecified) |
Open Circuit Voltage Continuity | 5 V ± 1 V |
Test Current Continuity | 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω) |
Voltage Range | AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 0 to 600 V |
Voltage Range Accuracy | AC: ±2% ±1 digit DC: ±2% ±2 digits |
Frequency Measurement Range | 15 Hz – 400 Hz |
Frequency Measurement Accuracy | ±0.5% ± 1 digit (100 Hz to 400 Hz unspecified) |
Capacitance Measurement | 1 nF to 10 μF |
Capacitance Measurement Accuracy | ± 5.0% ± 2 digits (0.1 nF – 1 nF unspecified) |
Storage Capacity | Greater than 1000 test results (Models MIT420/2 and MIT430/2) |
Data Download | Bluetooth® wireless, Class II, up to 10 m range (MIT430/2 only) |
Power Supply | 6 x 1.5 V cells type IEC LR6 (AA) Alkaline or 6 x 1.2 V NiMH rechargeable cells |
Battery Life | 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ |
Charger (Optional) | 12-15 V dc (accessory interface) |
Dimensions | 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in) |
Weight | 600 g (1.32 lb) (Model MIT400/2) |
Specifications
Related Products
FLUKE 393 FC : an epic True-rms Clamp Meter with iFlex
In stock
Fluke 368 FC Leakage Current Clamp Meter
In stock
Fluke 375 AC/DC Clamp Meter
In stock
FLUKE 177 True-RMS Digital Multimeter
In stock
Fluke 77 IV Digital Multimeter
In stock
Fluke 175 True-RMS Digital Multimeter
In stock
FLUKE 115 Digital Multimeter High Quality
In stock
Dominic –
Perfect thanks