What’s in the PCE-OC 15 Digital Multimeter Box

Here’s what comes in the PCE-OC 15 box:
-
PCE-OC 15 meter
-
1 set of test leads
-
Oscilloscope/DMM probe
-
Temperature sensor (K-type)
-
USB-C cable
-
User manual
-
Probe accessories (assorted)
PCE-OC 15 combines a full DMM with a built-in handheld oscilloscope: 10 MHz bandwidth, 48 MSa/s sampling, 1 kV DC / 750 V AC, 10 A, plus frequency, resistance, capacitance, and K-type temperature. Store screenshots to 15 MB internal memory and export via USB-C. Safety rated CAT III 600 V / CAT II 1000 V.
The PCE-OC 15 Digital Multimeter is a sophisticated instrument designed to meet the needs of both professionals and DIY enthusiasts. It stands out for its versatile measurement capabilities, allowing users to efficiently measure voltage, current, resistance, and temperature. This versatility makes it an essential tool for a wide range of applications, from electrical work to laboratory experiments.
The PCE-OC 15 Digital Multimeter is equipped with a variety of key features that enhance its functionality and user experience. Here are the main highlights:

Here’s what comes in the PCE-OC 15 box:
PCE-OC 15 meter
1 set of test leads
Oscilloscope/DMM probe
Temperature sensor (K-type)
USB-C cable
User manual
Probe accessories (assorted)
Yes—an integrated 1-channel handheld oscilloscope with 10 MHz bandwidth and up to 48 MSa/s sampling.
DC voltage up to ~1000 V (range 100–999.9 V), AC voltage up to 750 V, and AC/DC current up to 9.999
Timebase: 100 ns/div–20 s/div; vertical: 20 mV/div–10 V/div; input: 1 MΩ BNC; probe factors: ×1/×10; max input: 150 V. Functions include period, frequency, peak-to-peak, MAX/MIN, RMS.
Yes—auto measurement range selection is available for multimeter functions
| max___voltage____dc (multimeter) |
751 – 1000V DC |
|---|---|
| max___voltage____ac (multimeter) |
501 – 750V AC |
| auto___range (multimeter) |
Yes |
| true___rms (multimeter) |
No |
| max___current___dc (multimeter) |
0 to 10A |
| max___current___ac (multimeter) |
0 to 10A |
| Direct voltage DC | |
| Measurement range up to | 0 … 9,999 mV |
| Resolution | 0,001 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 10 … 99,99 mV |
| Resolution | 0,01 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 100 … 999,9 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 1 … 9,999 V |
| Resolution | 0,001 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 10 … 99,99 V |
| Resolution | 0,01 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 100 … 999,9 V |
| Resolution | 0,1 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 0 … 9999 µA |
| Resolution | 1 µA |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 10 … 99,99 mA |
| Resolution | 0,01 mA |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 100 … 999,9 mA |
| Resolution | 0,1 mA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 1 … 9,999 A |
| Resolution | 0,001 A |
| Accuracy | ±(1 % of Rd +3 digits) |
| Capacity | |
| Measurement range up to | 0 … 9,999 nF |
| Resolution | 0,001 nF |
| Accuracy | ±(5 % of Rd +20 digits) |
| Capacity | |
| Measurement range up to | 10 … 99,99 nF |
| Resolution | 0,01 nF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 100 … 999,9 nF |
| Resolution | 0,1 nF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 1 … 9,999 µF |
| Resolution | 0,001 µF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 10 … 99,99 µF |
| Resolution | 0,01 µF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 100 … 999,9 µF |
| Resolution | 0,1 µF |
| Accuracy | ±(5 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 1 … 9,999 mF |
| Resolution | 0,001 mF |
| Accuracy | ±(5 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 10 … 99,99 mF |
| Resolution | 0,01 mF |
| Accuracy | ±(5 % of Rd +5 digits) |
| AC voltage | |
| Measurement range up to | 0 … 9,999 mV |
| Resolution | 0,001 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 10 … 99,99 mV |
| Resolution | 0,01 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 100 … 999,9 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 1 … 9,999 V |
| Resolution | 0,001 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 10 … 99,99 V |
| Resolution | 0,01 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 100 … 750 V |
| Resolution | 0,1 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 0 … 9999 µA |
| Resolution | 1 µA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 10 … 99,99 mA |
| Resolution | 0,01 mA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 100 … 999,9 mA |
| Resolution | 0,1 mA |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 1 … 9,999 A |
| Resolution | 0,001 A |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Resistance | |
| Measurement range up to | 0 … 99,99 Ω |
| Resolution | 0,01 Ω |
| Accuracy | ±(1 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 100 … 999,9 Ω |
| Resolution | 0,1 Ω |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 1000 Ω … 9,999 kΩ |
| Resolution | 0,001 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 10 … 99,99 kΩ |
| Resolution | 0,01 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 100 … 999,9 kΩ |
| Resolution | 0,1 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 1000 kΩ … 9,999 M Ω |
| Resolution | 0,001 mΩ |
| Accuracy | ±(1.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 10 … 99,99 M Ω |
| Resolution | 0,01 mΩ |
| Accuracy | ±(3 % of Rd +5 digits) |
| Frequency | |
| Measurement range up to | 0 … 99,99 Hz |
| Resolution | 0,01 Hz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 100 … 999,9 Hz |
| Resolution | 0,1 Hz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 1000 Hz … 9,999 kHz |
| Resolution | 0,001 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 10 … 99,99 kHz |
| Resolution | 0,01 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 100 … 999,9 kHz |
| Resolution | 0,1 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Temperature | |
| Measurement range up to | -20 … +1000 °C |
| Resolution | 1 °C |
| Accuracy | ±(2.5 % of Rd +5 digits) |
| Temperature | |
| Measurement range up to | -4 … +1832 °F |
| Resolution | 1 °F |
| Accuracy | ±(2.5 % of Rd +5 digits) |
| Oscilloscope specifications | |
| Number of channels | 1 |
| Measuring functions | Period, Frequency, Peak-peak, MAX, MIN, RMS value |
| Sampling rate | 48 MSa/s |
| Input impedance | 1 M Ω |
| Probe factors | X1, X10 |
| Max. input voltage | 150 V |
| Adjustable sampling rate | 1.5 Sa/s … 48 MSa/s |
| Time base | 100 ns/div … 20 s/div |
| Accuracy | 20 ppm |
| Vertical sensitivity | 20 mV/div … 10 V/div |
| Rise time | 10 ns |
| DC gain accuracy | ±3 % |
| General technical data | |
| Display type | LCD |
| Display size | 2,76 Inch |
| Measuring rate | 3 Hz |
| Storage medium | Internal memory |
| Storage capacity | 15 MB |
| Memory information | Screenshot on keystroke |
| Interface | USB-C, BNC |
| Automatic power-off from…to | 15 … 120 min. |
| Automatic power-off can be deactivated | Yes |
| Safety standard | CAT III 600 V, CAT II 1000 V |
| Fuse(s) | Microfuse 10 A |
| Trigger input | Mode: auto, normal, single |
| Edge: rising, falling | |
| Menu language | English, Chinese, English (GB) |
| Protection class (device) | IP20 |
| Power supply | 100 … 240 V AC | 50/60 Hz |
| Weight | 352 g |
| Operating conditions | 0 … 40 °C , 0 … 75 % RH |
| Storage conditions | -20 … 60 °C , 0 … 80 % RH |
| (Rechargeable) battery | 1 x 3,7 V 18650 , lithium |
| Capacity | 2000 mAh |
| Dimensions ( L x W x H ) | 175 x 90 x 40 mm |