Amprobe AC68C TRMS 600 A Clamp Meter

Brand: Amprobe
SKU: 94381
Share

The Amprobe AC68C TRMS Clamp Meter stands out as a reliable and feature-rich tool for electrical professionals. Its combination of advanced measurement capabilities, safety ratings, and user-friendly design makes it a valuable addition to any technician’s toolkit. Whether for routine checks or complex diagnostics, the Amprobe AC68C delivers accurate and dependable results.

  • Safe Buy
  • Fast Delivery
  • Original Guarantee
  • Online Payment

Datasheet

Datasheet

specifications

Display: 3-3⁄4 digit, LCD, max reading of 3999
Display Update Rate: 2/sec, nominal
Power: 9 V battery (NEDA 1604, IEC 6F22)
Battery Life: 200 hours(Alkaline)
Operating Temperature: 0 °C to + 40 °C < 80 % R.H.
Storage Temperature: -10 °C to + 60 °C, < 70 % R.H. non-condensing
Maximum Jaw Opening: 40 mm (1.57 ̋)
Dimensions (WxHxD): 76 x 228 x 39 mm (3 ̋ x 9 ̋ x 1.5 ̋)
Weight (incl. Battery): 465 grams
Warranty: One-year
DC Voltage
Ranges 600 V ± (0.75 % rdg + 2 dgts)
Resolution 1 V in 600 V range
Input Impedance 10 MΩ
AC Voltage (40-450 Hz)
Range 400 V, 600 V ± (1.2 % rdg + 5 dgts)
Resolution 0.1 V in 400 V range
Input Impedance 10 MΩ
DC Current
Ranges 400 A, 600 A ± (2 % rdg + 5 dgts)
Resolution 0.1 A in 400 A range
AC Current (40-450 Hz)
Ranges 400 A, 600 A ± (2 % rdg + 5 dgts)
Resolution 0.1 A in 400 A range
Frequency (Hz), Current and Voltage
Ranges 4 kHz, 20 kHz ± (0.5 % rdg + 5 dgts)
Resolution 1 Hz in 4 kHz range
Sensitivity 5 A/1 V in 4 kHz range, 5 A/5 V in 20 kHz range
Resistance
Range 4 kW ± ( 1.0 % rdg + 5 dgts)
Resolution 1 W in 4 kW range
Open Circuit Volts 0.5 V DC
Max Short Circuit Current 0.8 mA
Diode Test
Resolution 0.001 V
Open Circuit Volts 3.2 V DC
Max Short Circuit Current 0.8 mA
Continuity
Range Threshold Tone at 40 W ± 15 W
Open Circuit Volts 3.2 V DC
Max Short Circuit Current 0.8 mA
Peak Hold Measurement AC Voltage (40-450 Hz)
Range 400 V, 600 V ± (1.5 % rdg + 10 dgts)
Resolution 0.1 V in 400 V range
Input Impedance 10 MΩ
Peak Hold Measurement AC Current (40-450 Hz)
Range 400 A, 600 A ± (2.0 % rdg + 10 dgts)
Resolution 0.1 A in 400 A range
Overload Protection
Voltage 1000 V DC/750 V AC
Current 800 Amps
Resistance 660 V RMS
Diode 660 V RMS