Amprobe AC68C TRMS 600 A Clamp Meter
Short Description:
The Amprobe AC68C TRMS Clamp Meter stands out as a reliable and feature-rich tool for electrical professionals. Its combination of advanced measurement capabilities, safety ratings, and user-friendly design makes it a valuable addition to any technician’s toolkit. Whether for routine checks or complex diagnostics, the Amprobe AC68C delivers accurate and dependable results.
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Amprobe AC68 C
The Amprobe AC68C TRMS Clamp Meter is a professional-grade digital multimeter designed for electrical technicians and engineers. It combines advanced measurement capabilities with user-friendly features, making it a versatile tool for various applications.
Key Features
- True RMS Measurement: The Amprobe AC68C is equipped with True RMS technology, allowing for accurate measurements of both AC and DC currents, even in non-linear loads.
- Measurement Range: It can measure AC and DC voltage up to 600 V and current up to 600 A, making it suitable for a wide range of electrical tasks.
- Functions: The meter offers 8 functions and 11 measurement ranges, including frequency, resistance, diode testing, and continuity testing. This versatility makes it a go-to tool for many electrical applications.
- Display: It features a 4000-count display, providing clear and precise readings with a maximum display of 3999. The large screen enhances visibility, especially in low-light conditions.
- Safety Ratings: The AC68C is rated CAT II 600 V and CAT III 300 V, ensuring it can be used safely in various electrical environments.
- Additional Features: It includes functions such as data hold, AC peak hold, and DC auto zero, which enhance its usability in different scenarios.
Design and Usability
The Amprobe AC68C is designed for ease of use. Its compact and ergonomic shape fits comfortably in the hand. The intuitive layout of buttons and functions allows users to navigate through settings quickly. It comes with essential accessories, including test leads and a carrying case, making it convenient for fieldwork.
Applications
The Amprobe AC68C clamp meter is ideal for:
- Electricians performing routine maintenance and troubleshooting.
- HVAC technicians require precise measurements for system diagnostics.
- Engineers are conducting tests in industrial settings.
AC Voltage Ranges |
400 V, 600 V |
---|---|
AC Voltage Accuracy |
± (1.2 % rdg + 5 dgts) |
AC Voltage Input Impedance |
10 MΩ |
DC Voltage Ranges |
600 V |
DC Voltage Accuracy |
± (0.75 % rdg + 2 dgts) |
DC Voltage Input Impedance |
10 MΩ |
Resistance Range |
4 MΩ |
Resistance Accuracy |
± (1.0 % rdg + 5 dgts) |
Open Circuit voltage |
0.5 V DC |
AC Current Ranges |
400 A, 600 A |
AC Current Accuracy |
± (2 % rdg + 5 dgts) |
DC Current Ranges |
400 A, 600 A |
DC Current Accuracy |
± (2 % rdg + 5 dgts) |
Frequency Ranges |
4 kHz, 20 kHz |
Frequency Accuracy |
± (0.5 % rdg + 5 dgts) |
Diode Test Accuracy |
± (1.0 % rdg + 2 dgts) |
Continuity Range |
Tone at 40 Ω ± 15 Ω |
Jaw opening/Conductor diameter |
40 mm (1.57 ̋) |
Power Supply |
9 V battery (NEDA 1604, IEC 6F22) |
Display |
3-3⁄4 digit, LCD, max reading of 3999 |
Dimensions |
76 x 228 x 39 mm (3 ̋ x 9 ̋ x 1.5 ̋) |
Weight |
465 grams |
Operating temperature |
0 °C to + 40 °C < 80 % R.H. |
Storage temperature |
– 10 °C to + 60 °C, < 70 % R.H. non-condensing |
Overload Protection |
Voltage 1000 V DC/750 V AC |
specifications
Display: | 3-3⁄4 digit, LCD, max reading of 3999 |
Display Update Rate: | 2/sec, nominal |
Power: | 9 V battery (NEDA 1604, IEC 6F22) |
Battery Life: | 200 hours(Alkaline) |
Operating Temperature: | 0 °C to + 40 °C < 80 % R.H. |
Storage Temperature: | -10 °C to + 60 °C, < 70 % R.H. non-condensing |
Maximum Jaw Opening: | 40 mm (1.57 ̋) |
Dimensions (WxHxD): | 76 x 228 x 39 mm (3 ̋ x 9 ̋ x 1.5 ̋) |
Weight (incl. Battery): | 465 grams |
Warranty: | One-year |
DC Voltage | |
Ranges | 600 V ± (0.75 % rdg + 2 dgts) |
Resolution | 1 V in 600 V range |
Input Impedance | 10 MΩ |
AC Voltage (40-450 Hz) | |
Range | 400 V, 600 V ± (1.2 % rdg + 5 dgts) |
Resolution | 0.1 V in 400 V range |
Input Impedance | 10 MΩ |
DC Current | |
Ranges | 400 A, 600 A ± (2 % rdg + 5 dgts) |
Resolution | 0.1 A in 400 A range |
AC Current (40-450 Hz) | |
Ranges | 400 A, 600 A ± (2 % rdg + 5 dgts) |
Resolution | 0.1 A in 400 A range |
Frequency (Hz), Current and Voltage | |
Ranges | 4 kHz, 20 kHz ± (0.5 % rdg + 5 dgts) |
Resolution | 1 Hz in 4 kHz range |
Sensitivity | 5 A/1 V in 4 kHz range, 5 A/5 V in 20 kHz range |
Resistance | |
Range | 4 kW ± ( 1.0 % rdg + 5 dgts) |
Resolution | 1 W in 4 kW range |
Open Circuit Volts | 0.5 V DC |
Max Short Circuit Current | 0.8 mA |
Diode Test | |
Resolution | 0.001 V |
Open Circuit Volts | 3.2 V DC |
Max Short Circuit Current | 0.8 mA |
Continuity | |
Range Threshold | Tone at 40 W ± 15 W |
Open Circuit Volts | 3.2 V DC |
Max Short Circuit Current | 0.8 mA |
Peak Hold Measurement AC Voltage (40-450 Hz) | |
Range | 400 V, 600 V ± (1.5 % rdg + 10 dgts) |
Resolution | 0.1 V in 400 V range |
Input Impedance | 10 MΩ |
Peak Hold Measurement AC Current (40-450 Hz) | |
Range | 400 A, 600 A ± (2.0 % rdg + 10 dgts) |
Resolution | 0.1 A in 400 A range |
Overload Protection | |
Voltage | 1000 V DC/750 V AC |
Current | 800 Amps |
Resistance | 660 V RMS |
Diode | 660 V RMS |