Amprobe ACDC-100 TRMS 1000 A AC/DC Clamp Meter
Short Description:
The Amprobe ACDC-100 TRMS 1000 A AC/DC Clamp Meter stands out as a high-quality, multifunctional tool that meets the needs of electricians and technicians, providing a balance of performance, durability, and user-friendly features.
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
18
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Amprobe ACDC 100 TRMS
The Amprobe ACDC-100 TRMS 1000 A AC/DC Clamp Meter is a versatile and robust tool designed for electrical professionals requiring accurate AC and DC currents measurements. This clamp meter is particularly noted for its true RMS capability, which allows it to provide accurate readings even in non-sinusoidal waveforms. This makes it ideal for a variety of applications in industrial and commercial settings.
Key Features
Measurement Capabilities
- AC Current: Measures up to 800 A
- DC Current: Measures up to 1000 A
- AC/DC Voltage: Ranges from 400.0 mV to 600 V
- Resistance: Up to 40 MΩ
- Capacitance: Up to 3000 µF
- Continuity Testing: Equipped with a beeper for quick identification of continuity
Design and Ergonomics
- Jaw Size: The large jaws can accommodate conductors up to 2 inches (50 mm) in diameter, allowing for easy clamping around various wire sizes.
- Ergonomic Design: The clamp meter features a rubber over-molded casing for better grip and durability, enhancing user comfort during prolonged use.
Additional Features
- Data Hold Function: Freezes the current reading on the display for easy note-taking.
- Relative Zeroing Mode: Allows users to set a reference point for measurements, enhancing accuracy in comparative readings.
- Auto Power Off: Automatically turns off the device after a period of inactivity to conserve battery life.
- MAX Capturing Function: Captures inrush current measurements, useful for analyzing equipment startup currents.
Datasheet
Specifications
General Specifications | |
Display | 3-3/4 digits 4000 counts LCD display |
Update Rate | 3 per second nominal |
Polarity | Automatic |
Low Battery | Below approx. 2.4V |
Operating Temperature | 0C to 40C |
Relative Humidity | Maximum relative humidity 80% for temperature up to 31C, decreasing linearly to 50% relative humidity at 40C |
Altitude | Operating below 2000m |
Storage Temperature | -20C to 60C, < 80% R.H. (with battery removed) |
Temperature Coefficient | nominal 0.15 x (specified accuracy)/ C @(0C -18C or 28C -40C), or otherwise specified |
Sensing | True RMS |
Safety | Meets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003)Â Category III 600 Volts AC & DC. |
Transient protection | 6.5kV (1.2/50μs surge) for all models |
Pollution degree | 2 |
E.M.C. | Meets EN61326-1 |
Overload Protections | |
Clamp-on jaws | DC 1000A or AC 800A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms |
Power Supply | standard 1.5V AAA Size (NEDA 24G or IEC R03)Â battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03)Â alkaline battery X 2 |
Power Consumption | typical 11mA for ACA/DCA and 2.9mA for other functions |
APO Timing | Idle for 30 minutes |
APO Consumption | typical 190μA |
Dimension | L227mm X W78mm X H40mm |
Weight | 290 gm approx |
Jaw opening & Conductor diameter | 50mm max |
Electrical Specifications | Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23? ± 5? & less than 75% R.H. | |
DC Voltage | ||
400.0 mV | 0.3% + 3d | |
4.000V, 40.00V, 400.0V | 0.5% + 3d | |
600V | 1.0% + 4d | |
NMRR : | >50dB @ 50/60Hz | |
CMRR : | >120dB @ DC, 50/60Hz, Rs=1kΩ | |
Input Impedance : | 10MΩ, 30pF nominal (1000MΩ for 400.0mV range) | |
AC Voltage | ||
50Hz ~ 500Hz | 400.0mVÂ 1) | 4.0% + 4d |
50Hz ~ 60Hz | 4.000V, 40.00V, 400.0V | 1.0% + 4d |
60Hz ~ 500Hz | 4.000V, 40.00V, 400.0V | 1.5% + 4d |
50Hz ~ 500Hz | 600V | 2.0% + 4d |
CMRR : | >60dB @ DC to 60Hz, Rs=1kΩ | |
Input Impedance: | 10MΩ, 30pF nominal | |
ACDC-100 TRMS Crest Factor: | < 1.6 : 1 at full scale & < 3.2 : 1 at half scale | |
1)Â Selection by RANGE button manually, and is specified AC 60mV and up | ||
Resistance | ||
400.0Ω | 0.8% + 6d | |
4.000kΩ, 40.00kΩ, 400.0kΩ | 0.6% + 4d | |
4.000MΩ | 1.0% + 4d | |
40.00MΩ | 2.0% + 4d | |
Open Circuit Voltage : | 0.4VDC typical | |
Audible Continuity Tester | ||
Open Circuit Voltage: | 0.4VDC typical | |
Range: 400.0Ω; Accuracy: | 1.5% + 6d | |
Audible threshold: | between 10Ω and 120Ω. | |
Diode Tester | ||
Open Circuit Voltage | Test Current (Typical) | |
< 1.6 VDC | 0.4mA | |
Capacitance | ||
500.0nF, 5.000μF, 50.00μF, | 3.5% + 6d2) 3) | |
500.0μF, 3000μF 1) | ||
1)Â Additional 50.00nF range accuracy is not specified | ||
2)Â Accuracies with film capacitor or better | ||
3)Â Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery | ||
warning voltage of approximately 2.4V | ||
DC Current (Clamp-on) | ||
400.0A | 0.0A ~ 400.0A | 1.5% + 4d 1) 2) |
1000A | 400A ~ 800A | 1.5% + 4d 1) 2) |
800A ~ 900A | 2.0% + 4d 1) 2) | |
900A ~ 1000A | 5.0% + 30d 1) 2) | |
1)Â Induced error from adjacent current-carrying conductor: < 0.01A/A | ||
2) Δ Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A. | ||
AC Current (Clamp-on) | ||
400.0A | ||
15Hz ~ 40Hz | 2.0% + 5d 1) 2) 3) | |
40Hz ~ 200Hz | 1.5% + 5d 1) 2) | |
200Hz ~ 400Hz @ <50A 4) | 1.5% + 5d 1) 2) | |
400Hz ~ 1kHz @ <50A 4) | 2.0% + 5d 1) 2) | |
800A | ||
15Hz ~ 40Hz @ 400A ~ 600A | 2.0% + 5d 1) 2) 3) | |
40Hz ~ 100Hz @ 400A ~ 600A | 1.5% + 4d 1) 2) | |
15Hz ~ 60Hz @ 600A ~ 800A | 5.0% + 30d 1) 2) | |
1)Â Induced error from adjacent current-carrying conductor: < 0.01A/A | ||
2)Â ACDC-100 TRMS crest Factor: < 1.6 : 1 at full scale & < 3.2 : 1 at half scale | ||
3)Â 4.0% + 5d for ACDC-100 TRMS | ||
4)Â Accuracy is specified at <50A in this frequency bandwidth due to limited calibrator output capability for testing |