Amprobe ACDC-100 1000 A AC/DC Clamp Meter

Brand: Amprobe
SKU: 94381-1-1-1
Share

The Amprobe ACDC-100 1000 A AC/DC Clamp Meter is a trusted tool that combines quality, functionality, and ease of use, making it a valuable asset for anyone working in electrical diagnostics and maintenance.

  • Safe Buy
  • Fast Delivery
  • Original Guarantee
  • Online Payment

Datasheet

Datasheet

Specifications

General Specifications
Display 3-3/4 digits 4000 counts LCD display
Update Rate 3 per second nominal
Polarity Automatic
Low Battery Below approx. 2.4V
Operating Temperature 0°C to 40°C
Relative Humidity Maximum relative humidity 80% for temperature up to 31°C decreasing linearly to 50% relative humidity at 40°C
Altitude Operating below 2000m
Storage Temperature -20°C to 60°C, < 80% R.H. (with battery removed)
Temperature Coefficient nominal 0.15 x (specified accuracy)/ °C @(0°C -18°C or 28°C -40°C), or otherwise specified
Sensing Average sensing
Safety Meets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) Category III 600 Volts AC & DC.
Transient protection 6.5kV (1.2/50µs surge) for all models
Pollution degree 2
E.M.C. Meets EN61326-1
In an RF field of 3V/m Capacitance function is not specified. Other function ranges: Total Accuracy = Specified Accuracy + 45 digits. Performance above 3V/m is not specified.
Overload Protections Clamp-on jaws: DC 1000A or AC 800A rms continuous + & COM terminals (all functions) – 600VDC/VAC rms
Power Supply standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2
Power Consumption typical 11mA for ACA/DCA and 2.9mA for other functions
APO Timing Idle for 30 minutes
APO Consumption typical 10µA
Dimension L227mm X W78mm X H40mm
Weight 290 gm approx
Jaw opening & Conductor diameter 50mm max
Electrical Specifications Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23°C ± 5°C & less than 75% R.H.
DC Voltage
400.0 mV
4.000V, 40.00V, 400.0V
600V
NMRR : >50dB @ 50/60Hz
CMRR : >120dB @ DC, 50/60Hz, Rs=1kΩ
Input Impedance : 10MO, 30pF nominal (1000MΩ for 400.0mV range)
AC Voltage
50Hz ~ 500Hz 400.0mV 1)
50Hz ~ 60Hz 4.000V, 40.00V, 400.0V
60Hz ~ 500Hz 4.000V, 40.00V, 400.0V
50Hz ~ 500Hz 600V
CMRR : >60dB @ DC to 60Hz, Rs=1kΩ
Input Impedance: 10MΩ, 30pF nominal
1) Selection by RANGE button manually, and is specified from AC 40mV and up
Resistance
400.0O
4.000kΩ, 40.00kΩ, 400.0kΩ
4.000MΩ
40.00MΩ
Open Circuit Voltage : 0.4VDC typical
Audible Continuity Tester
Open Circuit Voltage: 0.4VDC typical
Range: 400.0Ω; Accuracy: 1.5% + 6d
Audible threshold: between 10Ω and 120Ω.
Diode Tester
Open Circuit Voltage Test Current (Typical)
< 1.6 VDC 0.4mA
Capacitance
500.0nF, 5.000µF, 50.00µF,500.0µF, 3000µF 1)
1) Additional 50.00nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery
warning voltage of approximately 2.4V
DC Current (Clamp-on)
400.0A 0.0A ~ 400.0A
1000A 400A ~ 800A
800A ~ 900A
900A ~ 1000A
1) Induced error from adjacent current-carrying conductor: < 0.01A/A
2) δ Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A.
AC Current (Clamp-on)
400.0A
15Hz ~ 40Hz
40Hz ~ 200Hz
200Hz ~ 400Hz @ <50A 2)
400Hz ~ 1kHz @ <50A 2)
800A
15Hz ~ 40Hz @ 400A ~ 600A
40Hz ~ 100Hz @ 400A ~ 600A
15Hz ~ 60Hz @ 600A ~ 800A
1) Induced error from adjacent current-carrying conductor: < 0.01A/A
2) Accuracy is specified at <50A in this frequency bandwidth due to limited calibrator output capability for testing