Fluke 1773/Basic Power Quality Analyzer
- True RMS power quality analyzer with voltage up to 1000 V
- Current measurement with Rogowski clamp flexibility (4 A to 6000 A)
- Voltage harmonics, interharmonics, and THD up to 100%
- Flicker monitoring (Pst, Plt, Pinst) 0 to 20
- Frequency range 42.5 Hz to 69 Hz for grid analysis
- AUX input ±10 V for external sensor integration
- Compact design for industrial and field service use
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
Current range note (Fluke 1773/Basic): The analyzer itself does not have a single fixed current range—measured current depends on the connected clamp/iFlex accessory (e.g., iFlex 1500/3000/6000 A or AC clamps 40/400 A) per Fluke 1770 series specifications.
The Fluke 1773/Basic is a true RMS power quality analyzer designed for engineers and technicians who need to diagnose complex electrical issues in industrial and commercial environments. With the ability to capture voltage transients up to ±8 kVpk and measure current using flexible Rogowski clamps from 4 A to 6000 A, this instrument provides the visibility required to maintain system reliability and efficiency. Its wide frequency range and comprehensive harmonic analysis make it an essential tool for any power quality assessment.
Fluke 1773/BASIC Key Features
This power quality analyzer delivers comprehensive measurement capabilities across voltage and current parameters. It supports voltage harmonics and interharmonics up to 100%, with THD measurement on both voltage and current channels. The device can capture voltage distortions from 2 kHz to 30 kHz, ensuring high-frequency noise is not overlooked. Current measurement is highly versatile, supporting AC clamps from 40 A to 400 A, and Rogowski clamps in multiple ranges including 1500 A, 3000 A, and 6000 A configurations. Additional features include flicker monitoring (Pst, Plt, Pinst), mains signaling voltage analysis up to 3 kHz, and an AUX input for ±10 V external sensors.
- Voltage range: up to 1000 V
- Voltage transients: ±8 kVpk
- Voltage harmonics/interharmonics: 100%
- THD on voltage: 100%
- Voltage distortions 2-9 kHz: Max 100 V
- Voltage distortions 9-30 kHz: Max 100 V
- Current with iFlex 1500 A: 24 A to 1500 A
- Current with iFlex 3000 A: 24 A to 3000 A
- Current with iFlex 6000 A: 36 A to 6000 A
- AC clamp 40 A: 4 A to 40 A
- AC clamp 400 A: 40 A to 400 A
- AC/DC clamp 2000 A: 200 A to 2000 A
- Current min/max: 100%
- Current harmonics/interharmonics: 100%
- THD on current: 100%
- Frequency: 42.5 Hz to 69 Hz
- Voltage unbalance: 100%
- Current unbalance: 100%
- Flicker: Pst, Plt, Pinst 0 to 20
- Mains signaling voltage: up to 3 kHz, 0-15% of Vnom
- AUX input: ±10 V
Who Needs the Fluke 1773/BASIC?
Electrical engineers and maintenance technicians will find the Fluke 1773/BASIC indispensable for troubleshooting power distribution issues and ensuring compliance with efficiency standards. The instrument’s ability to capture transient events and analyze harmonic distortion makes it ideal for identifying the root causes of equipment overheating or nuisance tripping. Facility managers responsible for energy optimization will appreciate the detailed flicker and unbalance data, which can reveal opportunities for power factor correction and reduced utility costs. Contractors and consulting engineers will rely on its robust logging capabilities for audit reports and system commissioning projects.
Beyond the workshop, this analyzer serves utility professionals and energy auditors who need to verify power quality at the service entrance or within complex industrial processes. The ability to measure flicker indices (Pst, Plt, Pinst) is critical for meeting regulatory standards and protecting sensitive loads. Whether performing routine maintenance, investigating a power disturbance, or conducting an energy audit, the Fluke 1773/BASIC provides the data depth required to make informed decisions and protect valuable equipment from power-related damage.
Fluke 1773/BASIC Applications
In manufacturing plants, the Fluke 1773/BASIC is used to monitor the power quality driving large motor drives and variable frequency systems, helping to reduce downtime and extend equipment life. It is equally effective in commercial buildings where it can identify harmonic distortion from IT equipment and lighting systems that may interfere with other devices. For data centers, the analyzer ensures that the power feeding critical servers remains within acceptable limits, preventing unexpected shutdowns and data loss. Utility companies rely on the device for field surveys of the distribution grid, capturing transient events and voltage sags that affect end-users.
Renewable energy installations, such as solar and wind farms, benefit from the Fluke 1773/BASIC’s ability to analyze the quality of power fed into the grid and diagnose performance issues in inverters. The flicker monitoring function is particularly valuable for compliance with grid interconnection standards. Additionally, the analyzer is an excellent tool for educational institutions training the next generation of electrical engineers, providing hands-on experience with real-world power quality challenges and measurement techniques.
Why Buy Fluke 1773/BASIC from MME?
MME is your MME for genuine Fluke test and measurement equipment in the UAE. When you purchase the Fluke 1773/BASIC from MME, you receive a factory-backed warranty and access to local technical support, ensuring you have assistance whenever you need it. Our streamlined ordering process and reliable delivery mean you can get back to diagnosing power issues without delay. We understand the importance of uptime, which is why we stock the tools that keep your operations running smoothly.
MME guarantees authentic products with full manufacturer documentation. We pride ourselves on offering competitive pricing and expert advice to help you select the right instrument for your specific application. Trust MME for your Fluke power quality needs and experience the confidence that comes with genuine equipment and dedicated service.
Ready to enhance your power quality analysis? The Fluke 1773/BASIC is available now at MME. Our knowledgeable team is ready to assist you with product selection and answer any technical questions you may have. Visit mme-ae.com today to place your order and ensure your electrical systems are operating at peak performance.
Fluke 1773/BASIC Specifications
| Parameter | Range | Resolution | Intrinsic Accuracy at Reference Conditions % of Reading + % of Full Scale |
|
|---|---|---|---|---|
| Voltage | 1000 V | 0.1 V | 0.1 % of nominal voltage in accordance with IEC 61000-4-30 Class A1,2 ±(0.04 % + 0.004 %)3 |
|
| Voltage dips and swells | – | 0.1 V | 0.2 % of Vnom1,2 | |
| Voltage transients | ±8 kVpk | – | ±5 % +0.25 %) | |
| Voltage harmonics/interharmonics | 100 % | 0.1 % / 0.1 mV | ≥1 % Vnom1: ±2.5 % of rdg. <1 % Vnom1: ±0.025 Vnom |
|
| THD on voltage | 100 % | 0.1 % / 0.1 V | ±(2.5 % + 0.5 %) | |
| Voltage distortions 2-9 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
| Voltage distortions 9-30 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
| Current (Rogowski clamp mode) |
With iFlex 1500 A, i17XX-FLEX1500 24 |
150 A 1500 A |
0.01 % 0.1 A |
±(1 % + 0.02 %) |
| With iFlex 3000 A, i17XX-FLEX3000 24 |
300 A 3000 A |
0.01 A 0.1 A |
±(1 % + 0.03 %) | |
| With iFlex 6000 A, i17XX-FLEX6000 36 |
600 A 6000 A |
0.1 A 1 A |
±(1.5 % + 0.03 %) | |
| With AC clamp 40 A, i40s-EL |
4 A 40 A |
0.001 A 0.01 A |
±(0.7 % + 0.02 %) | |
| With AC clamp 400 A, i400s-EL |
40 A 400 A |
0.01 A 0.1 A |
±(2 % + 0.2 %) ±(0.7 % + 0.1 %) |
|
| With AC/DC clamp 2000 A, 80i-2010s-EL |
200 A 2000 A |
0.01 A 0.1 A |
±(0.8 % + 0.2 %) | |
| Current min/max | 100 % | defined by accessory | x2 of intrinsic accuracy | |
| Current harmonics/interharmonics | 100 % | 0.1 % / 0.01 A | ≥3 % Inom: ±2.5 % of rdg.4 <3 % Inom: ±0.15 % of Inom |
|
| THD on current | 100 % | 0.1 % | ±(2.5 % + 0.5 %) | |
| Frequency | 42.5 Hz … 69 Hz | 0.001 Hz | ±0.01 Hz | |
| Voltage unbalance | 100 % | 0.1 % | ±0.15 % | |
| Current unbalance | 100 % | 0.1 % | ±0.15 % | |
| Flicker Pinst, Pst, Plt | 0 to 20 | 0.01 | 5 % | |
| Mains signaling voltage | Up to 3 kHz 0-15 % of Vnom |
0.1 V / 0.1 % | 1-3 % Vnom: ±0.15 % of Vnom 3-15 % Vnom: ±5 % of rdg. |
|
| AUX input | ±10 V | 0.1 mV | ±(0.2 % + 0.05 %) | |
| 1 Nominal voltage in the range of 100 V to 690 V. Also known as Udin. 2 0 °C to 45 °C: Intrinsic Accuracy x2. Outside of 0 °C to 45 °C: Intrinsic Accuracy x3 3 Only for calibration laboratories 4 With iFlex 1500A, I17XX-FLEX1500 24 |
||||
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.
Bench Multimeters
Reviews
Clear filtersThere are no reviews yet.