Fluke 3000 FC/EDA2 Combo Kit
- Accurate measurements for electrical diagnostics and troubleshooting
- Combines AC/DC voltage, current, and frequency measurements
- Diode and continuity testing for reliable results
- Compact and rugged design for harsh environments
- Meets the needs of electrical technicians and engineers
- Fluke 3000 FC/EDA2 Combo Kit is a versatile and reliable tool
- For accurate and efficient electrical measurements
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 3000 FC/EDA2 Combo Kit is a powerful and versatile tool for electrical diagnostics and troubleshooting. With its compact and rugged design, it is perfect for harsh environments and meets the needs of electrical technicians and engineers.
Featuring accurate measurements for AC/DC voltage, current, and frequency, this kit is ideal for a wide range of applications, from electrical panel testing to circuit analysis.
Fluke 3000 FC/EDA2 Combo Kit Key Features
The Fluke 3000 FC/EDA2 Combo Kit offers a range of key features, including:
- AC Voltage Accuracy: 2% + 3 (45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
- DC Voltage, Continuity, Resistance, Diode Test and Capacitance: 0.09% + 2 V, 0.15% + 2 V, 0.5% + 2 Ω, 0.5% + 1 Ω, 1.5% + 3 Ω, 1% + 2 Diode test, 1.2% + 2 µF
- AC and DC Current: 1.5% + 3 mA AC (45 Hz to 1 kHz), 0.5% + 3 mA DC 2
- Frequency: 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.1 Hz, 9.999 kHz / 0.001 kHz, 99.99 kHz / 0.01 kHz
Who Needs the Fluke 3000 FC/EDA2 Combo Kit?
The Fluke 3000 FC/EDA2 Combo Kit is designed for electrical technicians and engineers who require accurate and efficient measurements for electrical diagnostics and troubleshooting.
Whether you’re working on electrical panels, circuits, or other electrical systems, this kit provides the tools you need to get the job done.
Fluke 3000 FC/EDA2 Combo Kit Applications
- Electrical Panel Testing: Use the Fluke 3000 FC/EDA2 Combo Kit to test electrical panels and ensure they are functioning correctly.
- Circuit Analysis: Use the Fluke 3000 FC/EDA2 Combo Kit to analyze electrical circuits and identify any issues or problems.
- Electrical Troubleshooting: Use the Fluke 3000 FC/EDA2 Combo Kit to troubleshoot electrical issues and identify the root cause of problems.
- Electrical Maintenance: Use the Fluke 3000 FC/EDA2 Combo Kit to perform routine electrical maintenance and ensure that electrical systems are functioning correctly.
- Electrical Testing: Use the Fluke 3000 FC/EDA2 Combo Kit to test electrical systems and ensure they are functioning correctly.
Why Buy Fluke 3000 FC/EDA2 Combo Kit from Mohammad Mahdi Electronics?
At Mohammad Mahdi Electronics, we offer the Fluke 3000 FC/EDA2 Combo Kit at competitive prices and with excellent customer service.
Our team of experts is always available to help you with any questions or concerns you may have, and we offer a range of accessories and support services to ensure that you get the most out of your purchase.
Fluke 3000 FC/EDA2 Combo Kit Specifications
| AC Voltage | |||
| Range¹ / resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
||
| Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 | |
| 500 Hz to 1 kHz | 2.0% + 3 | ||
| 1. AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. |
|||
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
| mV | Range / resolution | 600.0 mV / 0.1 mV | |
| Accuracy | 0.09% + 2 | ||
| V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
|
| Accuracy | 0.09% + 2 0.15% + 2 |
||
| ))) | Range / resolution | 600 Ω / 1 Ω | |
| Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | ||
| Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ |
|
| Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 |
||
| Diode test | Range / resolution | 2.000 V / 0.001 V | |
| Accuracy | 1% + 2 | ||
| µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF |
|
| Accuracy | 1.2% + 2 10% typical |
||
| 1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | |||
| AC and DC Current | |||
| mA AC (45 Hz to 1 kHz) |
Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA |
|
| Accuracy | 1.5% + 3 | ||
| mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA |
|
| Accuracy | 0.5% + 3 | ||
| 1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. |
|||
| Frequency | |||
| Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz |
||
| Accuracy1 | 0.1% + 1 | ||
| 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||
| Input Characteristics | |||
| Overload protection | 1100 V RMS | ||
| Input impedance (nominal) | > 10 MΩ < 100 pF | ||
| Common mode rejection ratio (1 kΩ unbalance) |
> 120 dB at DC, 50 Hz or 60 Hz | ||
| Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
| Overload protection | 1100 V RMS | ||
| Input impedance (nominal) | > 10 MΩ < 100 pF | ||
| Common mode rejection ratio (1 kΩ unbalance) |
> 60 dB, DC to 60 Hz | ||
| Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
| Overload protection | 1100 V RMS | ||
| Input impedance (nominal) | > 10 MΩ < 100 pF | ||
| Common mode rejection ratio (1 kΩ unbalance) |
> 120 dB at DC, 50 Hz or 60 Hz | ||
| Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
| Open Circuit Test Voltage | |||
| Overload protection | 1100 V RMS | ||
| Input impedance (nominal) | < 2.7 V DC | ||
| Full scale voltage to 6 MΩ Full scale voltage 50 MΩ |
< 0.7 V DC < 0.9 V DC |
||
| Typical short circuit current | < 350 mA | ||
| Overload protection | 1100 V RMS | ||
| Input impedance (nominal) | < 2.7 V DC | ||
| Full scale voltage to 6 MΩ Full scale voltage 50 MΩ |
2.000 V DC | ||
| Typical short circuit current | < 1.1 mA | ||
| mA Function | |||
| Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | ||
| Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||
| MIN/MAX Recording Accuracy | |||
| DC functions | ± 12 counts for changes > 350 mS in duration. | ||
| AC functions | ± 40 counts for changes > 900 mS in duration. | ||
| General Specifications | |||
| Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | ||
| Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||
| Display (LCD) | Update rate | 4/sec | |
| Volts, amps, ohms | 6000 counts | ||
| Frequency | 10,000 counts | ||
| Capacitance | 1,000 counts | ||
| Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||
| Battery life | 250 hours minimum | ||
| RF communications | 2.4 GHZ ISM Band | ||
| RF communication range | Open air, unobstructed | Up to 20m | |
| Obstructed, sheetrock wall | Up to 6.5m | ||
| Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | ||
| Temperature | Operating | -10°C to 50°C | |
| Storage | -40°C to 60°C | ||
| Temperature coefficient | 0.1 X (specified accuracy) / °C ( 28°C) | ||
| Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) |
||
| Altitude | Operating | 2,000 m | |
| Storage | 12,000 m | ||
| Electromagnetic compatibility EMI, RFI, EMC, RF |
EN 61326–1:2006, EN 61326–2–2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE |
||
| Safety compliance | ANSI / ISA 61010–1 / (82.02.01): 3rd edition CAN / CSA-C22.2 No 61010-1-12: 3rd edition UL 61010–1: 3rd edition IEC / EN 61010–1:2010 |
||
| Certifications | CSA, FCC, CE | ||
| Ingress Protection (IP) rating | IP54 | ||
| Pollution Degree | 2 | ||
| Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||
| Weight | 340 g (12 oz) | ||
| Warranty | Three years | ||
| Not compatible with Fluke CNX test tools | |||