Fluke 972B / 972ES: temperature, humidity, and dew point in one meter
The Fluke 972B is a thermo-hygrometer for HVAC technicians and facility teams who check indoor conditions. It measures temperature from -30 °C to 65 °C with the internal sensor, or from -40 °C to 99.9 °C with the external sensor, at ±0.5 °C accuracy. It reads humidity from 0 to 99.9% RH, with ±3% RH accuracy between 20 and 80% RH, and it calculates dew point and wet bulb. It stores up to 99 readings and has Max/Min/Avg and an auto-logging mode. The 972ES is the external sensor on its own. In UAE data centres, cold stores, and pharma warehouses, teams use the 972B to show that rooms stay within their temperature and RH limits, and the dew-point reading helps them catch condensation risk on chilled-water lines before it causes damage.
See more instrumentation for HVAC and facilities, and read our HVAC measurement guide.
The Fluke 972 Series is an indispensable tool for facility maintenance teams and HVAC technicians working in various industries, including Food, Pharma, cold storage, Data-centres, Labs & R&D facilities, and Agricultural electronics manufacturing segments.
With its advanced temperature and humidity measurement capabilities, the Fluke Fluke 972B/972ES Temperature Humidity Meter is designed to provide accurate readings in a range of environments.
Fluke 972B Key Features
- Internal and external temperature measurement capabilities.
- ±3% RH accuracy for humidity readings.
- 2-line LCD display with backlight.
- Auto-off and data storage features.
- Max/Min/Avg temperature and humidity readings.
- Auto logging mode for up to 8 hours of continuous data collection.
Fluke 972B Applications
The Fluke Fluke 972B/972ES Temperature Humidity Meter is ideal for use in various industries, including:
- Facility maintenance teams.
- HVAC technicians.
- Food processing and storage facilities.
- Pharmaceutical manufacturing facilities.
- Data-centres and server rooms.
- Labs and R&D facilities.
- Agricultural electronics manufacturing segments.
Who Needs the Fluke 972B?
The Fluke Fluke 972B/972ES Temperature Humidity Meter is designed for professionals involved in indoor air quality assessment and monitoring.
Why Buy from Mohammad Mahdi Electronics?
Browse our instrumentation. Read more in our electrical safety standards guide. See other Fluke instruments.
At Mohammad Mahdi Electronics, we offer a wide range of products from top brands like Fluke. Our experienced team is dedicated to providing exceptional customer service and support. Browse our selection of Fluke products today and discover why we’re the trusted choice for professionals in the Middle East.
Fluke 972B Specifications
| 972B | 972ES | ||
| Detailed Specifications | |||
| Sensor Type | Internal + External | External | |
| Temperature Measurement Range | Internal sensor: -30.0 °C to 65.0 °C; External sensor: -40.0 °C to 99.9 °C |
-40.0 °C to 99.9 °C | |
| Temperature Accuracy | Internal sensor: ±0.5 °C (-30.0 °C to 65.0 °C) External sensor: ±0.5 °C (-30.0 °C to 65.0 °C); ±0.7 °C (others) |
±0.5 °C (-30.0 °C to 65.0 °C); ±0.7 °C (others) |
|
| Temperature Resolution | 0.1 °C | ||
| Dew Point Temperature | Range | -40.0 °C to 99.9 °C | N/A |
| Resolution | 0.1 °C | N/A | |
| Wet Bulb Temperature | Range | -20.0 °C to 60.0 °C | N/A |
| Resolution | 0.1 °C | N/A | |
| Humidity | Range | 0.0% RH to 99.9% RH | |
| Accuracy | ±3% RH (≥20.0% RH to ≤80.0% RH @ 25 ℃) ±5% RH (≥1% RH to 80% RH to ≤95% RH @ 25℃) Unspecified for others |
||
| Resolution | 0.1% RH | ||
| Data Storage | Yes. Up to 99 sets | N/A | |
| Display | 2-line LCD display, with backlight | No | |
| Auto-off | Power off after 20 min without any operation | N/A | |
| Max/Min/Avg | Yes | N/A | |
| Auto Logging Mode | Yes | N/A | |
| General Specifications | |||
| Temperature | Operating | -30 °C to 70 °C | -40 °C to 70 °C |
| Storage | -30 °C to 70 °C, <80% RH (without battery) | -40 °C to 70 °C, <80% RH | |
| Altitude | Operating | 2000 m | |
| Storage | 12 000 m | ||
| Relative Humidity | Operating | 0% RH to 99% RH | |
| Storage | <80% RH | ||
| Power Supply | Battery Type | 2 x AAA Batteries | — |
| Battery Life | 1000 hrs for continuous operating, backlight off | — | |
| Safety | IEC61010-1, Pollution Degree 2 | ||
| Dimensions (L x W x H) | 211 × 58 × 40 mm | 264 × 33 × 28 mm | |
| Weight | 172 g (body) | 127 g | |
| Electromagnetic Environment (EMC) | IEC 61326-1: Portable, Electromagnetic Environment; IEC 61326-2-2; CISPR 11: Group 1; Class A | ||
| Group 1: Equipment intentionally generates and/or uses conductive-coupled RF energy, which is necessary for its internal operation. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
|||
| IP Rating | IEC 60529: IP30, non-operating | ||
Fluke 972B FAQ
What is the difference between the Fluke 972A, 972B and 972ES?
The 972A has an internal sensor only. The 972B adds an external probe, dew point and wet bulb, 99-set memory, and auto-logging. The 972ES is the external sensor on its own.
How long can the 972B log automatically?
Fluke specifies auto-logging for up to 8 hours of automatic temperature and humidity monitoring. That is long enough to cover a shift in a server room, cold store or warehouse.
How accurate is the Fluke 972B?
Temperature accuracy is ±0.5 °C from -30 °C to 65 °C. Humidity accuracy is ±3% RH between 20% and 80% RH at 25 °C, and ±5% RH outside that band up to 95% RH.
Does the 972B calculate dew point?
Yes. It shows dew point from -40.0 °C to 99.9 °C and wet bulb from -20.0 °C to 60.0 °C. Technicians in the UAE use the dew-point reading to check condensation risk on chilled-water pipes and AHUs.
What battery does it use?
It runs on 2 × AAA batteries, rated for 1000 hours of continuous operation with the backlight off.
Specifications
Specifications
| 972B | 972ES | ||
| Detailed Specifications | |||
| Sensor Type | Internal + External | External | |
| Temperature Measurement Range | Internal sensor: -30.0 °C to 65.0 °C; External sensor: -40.0 °C to 99.9 °C |
-40.0 °C to 99.9 °C | |
| Temperature Accuracy | Internal sensor: ±0.5 °C (-30.0 °C to 65.0 °C) External sensor: ±0.5 °C (-30.0 °C to 65.0 °C); ±0.7 °C (others) |
±0.5 °C (-30.0 °C to 65.0 °C); ±0.7 °C (others) |
|
| Temperature Resolution | 0.1 °C | ||
| Dew Point Temperature | Range | -40.0 °C to 99.9 °C | N/A |
| Resolution | 0.1 °C | N/A | |
| Wet Bulb Temperature | Range | -20.0 °C to 60.0 °C | N/A |
| Resolution | 0.1 °C | N/A | |
| Humidity | Range | 0.0% RH to 99.9% RH | |
| Accuracy | ±3% RH (≥20.0% RH to ≤80.0% RH @ 25 ℃) ±5% RH (≥1% RH to <20% RH, >80% RH to ≤95% RH @ 25℃) Unspecified for others |
||
| Resolution | 0.1% RH | ||
| Data Storage | Yes. Up to 99 sets | N/A | |
| Display | 2-line LCD display, with backlight | No | |
| Auto-off | Power off after 20 min without any operation | N/A | |
| Max/Min/Avg | Yes | N/A | |
| Auto Logging Mode | Yes | N/A | |
| General Specifications | |||
| Temperature | Operating | -30 °C to 70 °C | -40 °C to 70 °C |
| Storage | -30 °C to 70 °C, <80% RH (without battery) | -40 °C to 70 °C, <80% RH | |
| Altitude | Operating | 2000 m | |
| Storage | 12 000 m | ||
| Relative Humidity | Operating | 0% RH to 99% RH | |
| Storage | <80% RH | ||
| Power Supply | Battery Type | 2 x AAA Batteries | — |
| Battery Life | 1000 hrs for continuous operating, backlight off | — | |
| Safety | IEC61010-1, Pollution Degree 2 | ||
| Dimensions (L x W x H) | 211 × 58 × 40 mm | 264 × 33 × 28 mm | |
| Weight | 172 g (body) | 127 g | |
| Electromagnetic Environment (EMC) | IEC 61326-1: Portable, Electromagnetic Environment; IEC 61326-2-2; CISPR 11: Group 1; Class A | ||
| Group 1: Equipment intentionally generates and/or uses conductive-coupled RF energy, which is necessary for its internal operation. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
|||
| IP Rating | IEC 60529: IP30, non-operating | ||
Datasheet