PCE-DC 25 Clamp Meter
Short Description:
The ergonomic design and user-friendly features of the PCE-DC 25 ensure that technicians can conduct safe and practical assessments even in challenging environments. For those who need a compact yet capable clamp meter, the PCE-DC 25 is an efficient and essential investment.
- Clamp Meter DC Voltage measuring range: 600.0 mV DC to 1000 V DC
- Clamp Meter AC Voltage measuring range: 6.000 V AC to 1000 V AC
- Clamp Meter Resistance measuring range: 600.0 Ω to 60.00 MΩ
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
18
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Buy PCE-DC 25
The Clamp Meter PCE-DC 25 is a versatile and compact tool designed to easily measure AC and DC currents, providing electricians and technicians with reliable, on-the-go measurements. Ideal for troubleshooting and maintenance tasks in industrial, residential, and commercial settings, the PCE-DC 25 simplifies electrical testing by enabling non-intrusive current measurements through its clamp mechanism. It is highly valued by professionals in Dubai and beyond for its portability, accuracy, and advanced functionality, making it essential for quick assessments and efficient diagnostics.
Key Features
The PCE-DC 25 Clamp Meter has various features that enhance its functionality and ease of use.
- Non-Contact Current Measurement: The PCE-DC 25’s clamp mechanism allows users to measure current in wires without disconnecting them, ensuring safety and efficiency during testing.
- AC/DC Current and Voltage Measurement: This clamp meter can measure AC and DC currents, making it versatile for various electrical systems.
- Temperature Measurement: In addition to electrical parameters, the PCE-DC 25 can measure temperature, providing a comprehensive diagnostic tool for technicians working with heating elements and temperature-sensitive systems.
- Continuity Test and Diode Test: The meter includes a continuity buzzer and diode testing function, which helps quickly check circuit conditions and verify semiconductor functionality.
- Portable and User-Friendly Design: Its ergonomic design and lightweight build allow technicians to carry and use it effortlessly, making it ideal for quick assessments in confined or hard-to-reach spaces.
The PCE-DC 25 Clamp Meter is a powerful tool for professionals who require a reliable, multipurpose device for electrical inspections. Its ability to measure current, voltage, and temperature, along with features like data hold and max/min readings, make it indispensable for diagnosing electrical systems accurately and efficiently. PCE-DC 25 ergonomic design and user-friendly features ensure technicians can conduct safe and practical assessments, even in challenging environments. For those needing a compact yet capable clamp meter, the PCE-DC 25 is an efficient and essential investment.
PCE-DC 25 Specifications
The PCE-DC 25 model offers a DC voltage measuring range of 600.0 mV with a resolution of 0.1 mV and an accuracy of ±(0.5% + 8 digits) and a range of 6.000 V DC with a resolution of 0.001 V DC.
Clamp Meter PCE-DC 25 | |
DC voltage | |
Measuring range | 600.0 mV DC |
Resolution | 0.1 mV DC |
Accuracy | ±(0.5 % + 8 digits) |
Measuring range | 6.000 V DC |
Resolution | 0.001 V DC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 60.00 V DC |
Resolution | 0.01 V DC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600.0 V DC |
Resolution | 0.1 V DC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 1000 V DC |
Resolution | 1 V |
Accuracy | ±(1.5 % + 5 digits) |
Input impedance | >10 MΩ |
Overvoltage protection | 1000 V AC/DC |
AC voltage | |
Measuring range | 6.000 V AC |
Resolution | 0.001 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 60.00 V AC |
Resolution | 0.01 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600.0 V AC |
Resolution | 0.1 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 1000 V AC |
Resolution | 1 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Peak value (PEAK) accuracy | ±10 % |
Peak value (PEAK) response time | 1 ms |
Input impedance | >10 MΩ |
Overvoltage protection | 1000 V AC/DC |
The accuracy relates to a measuring range of 10 … 100 % | |
with a sine wave. | |
Low pass filter (LowZ) | |
(50 … 400 Hz) | |
Measuring range | 6.000 V AC |
Resolution | 0.001 V AC |
Accuracy | ±(3.0 % + 40 digits) |
Measuring range | 60.00 V AC |
Resolution | 0.01 V AC |
Accuracy | ±(3.0 % + 40 digits) |
Measuring range | 300.0 V AC |
Resolution | 0.1 V |
Accuracy | ±(3.0 % + 40 digits) |
Input impedance | <300 kΩ |
Overvoltage protection | 1000 V AC/DC |
The accuracy relates to a measuring range of 10 … 100 % | |
with a sine wave. | |
AC with DC voltage | |
(50 … 400 Hz) | |
Measuring range | 6.000 V AC |
Resolution | 0.001 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Measuring range | 60.00 V AC |
Resolution | 0.01 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Measuring range | 600.0 V AC |
Resolution | 0.1 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Measuring range | 1000 V AC |
Resolution | 1 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Input impedance | >10 MΩ |
Direct current | |
Measuring range | 600.0 A DC |
Resolution | 0.1 A DC |
Accuracy | ±(2.5 % + 5 digits) |
Measuring range | 1000 A DC |
Resolution | 1 A DC |
Accuracy | ±(2.8 % + 5 digits) |
Overvoltage protection | 1000 A DC |
Alternating current | |
(50 … 60 Hz) | |
Measuring range | 600.0 A AC |
Resolution | 0.1 A AC |
Accuracy | ±(2.5 % + 5 digits) |
Measuring range | 1000 A AC |
Resolution | 1 A AC |
Accuracy | ±(2.8 % + 5 digits) |
Overload protection | 1000 A AC/DC |
Flexible clamp meter | |
(50 … 400 Hz) | |
Measuring range | 30.00 A AC |
Resolution | 0.01 A AC |
Accuracy | ±(3.0 % + 5 digits) |
Measuring range | 300.0 A AC |
Resolution | 0.1 A AC |
Accuracy | ±(3.0 % + 5 digits) |
Measuring range | 3000 A AC |
Resolution | 1 A AC |
Accuracy | ±(3.0 % + 5 digits) |
Overload protection | 3000 A AC/DC |
The accuracy relates to a measuring range of 10 … 100 % | |
with a sine wave. | |
Resistance | |
Measuring range | 600.0 Ω |
Resolution | 0.1 Ω |
Accuracy | ±(1.0 % + 10 digits) |
Measuring range | 6.000 kΩ |
Resolution | 0.001 kΩ |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 60.00 kΩ |
Resolution | 0.01 kΩ |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600.0 kΩ |
Resolution | 0.1 kΩ |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 6.000 MΩ |
Resolution | 0.001 MΩ |
Accuracy | ±(2.5 % + 5 digits) |
Measuring range | 60.00 MΩ |
Resolution | 0.01 MΩ |
Accuracy | ±(3.5 % + 10 digits) |
Overvoltage protection | 1000 V AC/DC |
Continuity test | |
Signal | <50 Ω |
Overvoltage protection | 1000 V AC/DC |
Diode test | |
Test current | <1.5 mA |
Maximum tension when open | 3.3 V DC |
circuit | |
Frequency measurement | |
Measuring range | 9.999 Hz … 99.99 kHz |
Resolution | 0.01 … 10 Hz |
Accuracy | ±(1.2 % + 5 digits) |
Overvoltage protection | 1000 V AC/DC |
Sensitivity | >5 Vrms with one duty cycle |
from 20 … 80 % | |
Duty cycle | |
Measuring range | 10.0 … 90.0 % |
Resolution | 0.10% |
Accuracy | ±(1.2 % + 8 digits) |
Pulse range | 40 Hz … 10 kHz |
Pulse amplitude | ±5 V (0.1 … 100 ms) |
Capacity | |
Measuring range | 60.00 nF |
Resolution | 0.01 nF |
Accuracy | ±(4.0 % + 20 digits) |
Measuring range | 600.0 nF |
Resolution | 0.1 nF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 6.000 µF |
Resolution | 0.001 µF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 60.00 µF |
Resolution | 0.01 µF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 600.0 µF |
Resolution | 0.1 µF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 6000 µF |
Resolution | 1 µF |
Accuracy | ±(5.0 % + 8 digits) |
Measuring range | 60.00 mF |
Resolution | 0.01 mF |
Accuracy | ±(5.0 % + 20 digits) |
Measuring range | 100.0 mF |
Resolution | 0.1 mF |
Accuracy | ±(5.0 % + 20 digits) |
Overvoltage protection | 1000 V AC/DC |
Temperature measurement | |
(Thermocouple Type K) | |
Measuring range | -40 … 600.0 °C |
Resolution | 0.1 °C |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600 … 1000 °C |
Resolution | 1 °C |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | -40 … 600.0 °F |
Resolution | 0.1 °F |
Accuracy | ±(1.5 % + 9 digits) |
Measuring range | 600 … 1800 °F |
Resolution | 1 °F |
Accuracy | ±(1.5 % + 9 digits) |
Overvoltage protection | 1000 V AC/DC |
The accuracy refers to the measuring device without a temperature probe. | |
Specifications refer to a stable ambient condition of ±1 °C. | |
If the measurement lasts for a long time, the measured value increases by 2 °C | |
Further specifications | |
Clamp opening | 34 mm / 1.3″ |
NCV | >150 V AC |
Display | LC colour display |
Display when measuring range exceeded | “OL” (overload) |
Measuring rate | 3 measured values per second |
Interface | Bluetooth |
Operating conditions | 5 … 40 °C / 41 … 104 °F |
<80 % RH non-condensing at | |
31 °C / 87 °F linearly decreasing to 50 % RH | |
non-condensing at 40 °C / 104 °F | |
Storage conditions | -20 … 40 °C / -4 … 140 °F <80 % RH |
non-condensing | |
Maximum working height | 2000 m / 7000 ft |
Power supply | 3 x 1.5 V AAA batteries |
Auto power off | Switched off, 15, 30, 45, 60 minutes |
Dimensions | 250 x 80 x 40 mm / 9.8 x 3.1 x 1.5″ |
Weight | 365 g / 12.8 oz |
Buy the PCE-DC 25 Clamp meter, a remarkable tool for measuring AC currents of up to 600 mV. It offers true RMS measurements for accurate readings, even with non-linear loads. The flexible clamp design ensures easy access to wires, while the large backlit screen displays all information.
Manual
Specifications
Clamp Meter PCE-DC 25 | |
DC voltage | |
Measuring range | 600.0 mV DC |
Resolution | 0.1 mV DC |
Accuracy | ±(0.5 % + 8 digits) |
Measuring range | 6.000 V DC |
Resolution | 0.001 V DC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 60.00 V DC |
Resolution | 0.01 V DC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600.0 V DC |
Resolution | 0.1 V DC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 1000 V DC |
Resolution | 1 V |
Accuracy | ±(1.5 % + 5 digits) |
Input impedance | >10 MΩ |
Overvoltage protection | 1000 V AC/DC |
AC voltage | |
Measuring range | 6.000 V AC |
Resolution | 0.001 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 60.00 V AC |
Resolution | 0.01 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600.0 V AC |
Resolution | 0.1 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 1000 V AC |
Resolution | 1 V AC |
Accuracy | ±(1.5 % + 5 digits) |
Peak value (PEAK) accuracy | ±10 % |
Peak value (PEAK) response time | 1 ms |
Input impedance | >10 MΩ |
Overvoltage protection | 1000 V AC/DC |
The accuracy relates to a measuring range of 10 … 100 % | |
with a sine wave. | |
Low pass filter (LowZ) | |
(50 … 400 Hz) | |
Measuring range | 6.000 V AC |
Resolution | 0.001 V AC |
Accuracy | ±(3.0 % + 40 digits) |
Measuring range | 60.00 V AC |
Resolution | 0.01 V AC |
Accuracy | ±(3.0 % + 40 digits) |
Measuring range | 300.0 V AC |
Resolution | 0.1 V |
Accuracy | ±(3.0 % + 40 digits) |
Input impedance | <300 kΩ |
Overvoltage protection | 1000 V AC/DC |
The accuracy relates to a measuring range of 10 … 100 % | |
with a sine wave. | |
AC with DC voltage | |
(50 … 400 Hz) | |
Measuring range | 6.000 V AC |
Resolution | 0.001 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Measuring range | 60.00 V AC |
Resolution | 0.01 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Measuring range | 600.0 V AC |
Resolution | 0.1 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Measuring range | 1000 V AC |
Resolution | 1 V AC |
Accuracy | ±(2.5 % + 20 digits) |
Input impedance | >10 MΩ |
Direct current | |
Measuring range | 600.0 A DC |
Resolution | 0.1 A DC |
Accuracy | ±(2.5 % + 5 digits) |
Measuring range | 1000 A DC |
Resolution | 1 A DC |
Accuracy | ±(2.8 % + 5 digits) |
Overvoltage protection | 1000 A DC |
Alternating current | |
(50 … 60 Hz) | |
Measuring range | 600.0 A AC |
Resolution | 0.1 A AC |
Accuracy | ±(2.5 % + 5 digits) |
Measuring range | 1000 A AC |
Resolution | 1 A AC |
Accuracy | ±(2.8 % + 5 digits) |
Overload protection | 1000 A AC/DC |
Flexible clamp meter | |
(50 … 400 Hz) | |
Measuring range | 30.00 A AC |
Resolution | 0.01 A AC |
Accuracy | ±(3.0 % + 5 digits) |
Measuring range | 300.0 A AC |
Resolution | 0.1 A AC |
Accuracy | ±(3.0 % + 5 digits) |
Measuring range | 3000 A AC |
Resolution | 1 A AC |
Accuracy | ±(3.0 % + 5 digits) |
Overload protection | 3000 A AC/DC |
The accuracy relates to a measuring range of 10 … 100 % | |
with a sine wave. | |
Resistance | |
Measuring range | 600.0 Ω |
Resolution | 0.1 Ω |
Accuracy | ±(1.0 % + 10 digits) |
Measuring range | 6.000 kΩ |
Resolution | 0.001 kΩ |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 60.00 kΩ |
Resolution | 0.01 kΩ |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600.0 kΩ |
Resolution | 0.1 kΩ |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 6.000 MΩ |
Resolution | 0.001 MΩ |
Accuracy | ±(2.5 % + 5 digits) |
Measuring range | 60.00 MΩ |
Resolution | 0.01 MΩ |
Accuracy | ±(3.5 % + 10 digits) |
Overvoltage protection | 1000 V AC/DC |
Continuity test | |
Signal | <50 Ω |
Overvoltage protection | 1000 V AC/DC |
Diode test | |
Test current | <1.5 mA |
Maximum tension when open | 3.3 V DC |
circuit | |
Frequency measurement | |
Measuring range | 9.999 Hz … 99.99 kHz |
Resolution | 0.01 … 10 Hz |
Accuracy | ±(1.2 % + 5 digits) |
Overvoltage protection | 1000 V AC/DC |
Sensitivity | >5 Vrms with one duty cycle |
from 20 … 80 % | |
Duty cycle | |
Measuring range | 10.0 … 90.0 % |
Resolution | 0.10% |
Accuracy | ±(1.2 % + 8 digits) |
Pulse range | 40 Hz … 10 kHz |
Pulse amplitude | ±5 V (0.1 … 100 ms) |
Capacity | |
Measuring range | 60.00 nF |
Resolution | 0.01 nF |
Accuracy | ±(4.0 % + 20 digits) |
Measuring range | 600.0 nF |
Resolution | 0.1 nF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 6.000 µF |
Resolution | 0.001 µF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 60.00 µF |
Resolution | 0.01 µF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 600.0 µF |
Resolution | 0.1 µF |
Accuracy | ±(3.0 % + 8 digits) |
Measuring range | 6000 µF |
Resolution | 1 µF |
Accuracy | ±(5.0 % + 8 digits) |
Measuring range | 60.00 mF |
Resolution | 0.01 mF |
Accuracy | ±(5.0 % + 20 digits) |
Measuring range | 100.0 mF |
Resolution | 0.1 mF |
Accuracy | ±(5.0 % + 20 digits) |
Overvoltage protection | 1000 V AC/DC |
Temperature measurement | |
(Thermocouple Type K) | |
Measuring range | -40 … 600.0 °C |
Resolution | 0.1 °C |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | 600 … 1000 °C |
Resolution | 1 °C |
Accuracy | ±(1.5 % + 5 digits) |
Measuring range | -40 … 600.0 °F |
Resolution | 0.1 °F |
Accuracy | ±(1.5 % + 9 digits) |
Measuring range | 600 … 1800 °F |
Resolution | 1 °F |
Accuracy | ±(1.5 % + 9 digits) |
Overvoltage protection | 1000 V AC/DC |
The accuracy refers to the measuring device without temperature probe. | |
Specifications refer to a stable ambient condition of ±1 °C. | |
If the measurement lasts for a long time, the measured value increases by 2 °C | |
Further specifications | |
Clamp opening | 34 mm / 1.3″ |
NCV | >150 V AC |
Display | LC colour display |
Display when measuring range exceeded | “OL” (overload) |
Measuring rate | 3 measured values per second |
Interface | Bluetooth |
Operating conditions | 5 … 40 °C / 41 … 104 °F |
<80 % RH non-condensing at | |
31 °C / 87 °F linearly decreasing to 50 % RH | |
non-condensing at 40 °C / 104 °F | |
Storage conditions | -20 … 40 °C / -4 … 140 °F <80 % RH |
non-condensing | |
Maximum working height | 2000 m / 7000 ft |
Power supply | 3 x 1.5 V AAA batteries |
Auto power off | Switched off, 15, 30, 45, 60 minutes |
Dimensions | 250 x 80 x 40 mm / 9.8 x 3.1 x 1.5″ |
Weight | 365 g / 12.8 oz |
Related Products
Fluke 381 Remote Display AC/DC Clamp Meter with iFlex
Rated 5.00 out of 5
(2)
In stock
Call for Price
Kyoritsu KEW 2500 DC Milliamp Clamp Meter
Rated 5.00 out of 5
(1)
In stock