Senko SI-310 Fixed Gas Detector
The Senko SI-310 Fixed Gas Detector is an advanced solution for gas monitoring in industrial environments. It features innovative sampling technology, a user-friendly interface, and a durable design, making it an essential tool for improving safety and ensuring compliance in areas where hazardous gases may be present.
- Built-in flow control function
- Large LCD with Digital Concentration Indication and Digital Flow Indication
- Control set of 4 Button / RS485 / TCP Ethernet / Bluetooth
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Buy Senko SI-310
The Senko SI-310 is a state-of-the-art fixed gas detector engineered explicitly for industrial environments where the detection of hazardous gases is paramount. This device utilizes advanced pyrolyzer sampling technology, allowing it to accurately identify a variety of gases, including Hexafluorobutadiene, Octafluorocyclopentene, Difluoromethane, and Fluoromethane. Its ability to monitor these gases makes it an essential tool for industries such as chemical manufacturing and semiconductor production, where safety and compliance are critical.
One of the key advantages of the SI-310 is its built-in sampling system, which enables efficient gas detection even in challenging environments. This feature ensures that the device can continuously sample air from various locations, providing real-time data on gas concentrations and enhancing overall workplace safety.
Key Features
The Senko SI-310 has several features that make it an ideal tool. These features include:
- Advanced Sampling Technology: The SI-310 incorporates a pyrolyzer sampling mechanism for precise gas detection. This technology ensures that even trace amounts of gases can be accurately monitored, making it highly effective in environments where gas leaks may occur.
- User-Friendly Interface: The device features a clear digital display that provides real-time readings of gas concentrations. This intuitive interface allows operators to assess conditions and quickly respond to potential hazards.
- Robust Alarm System: The SI-310 has audible and visual alarms that activate when gas levels exceed predefined thresholds. This proactive alert system is crucial for ensuring immediate action to mitigate risks.
- Durable Design: The SI-310’s rugged casing protects it from dust and moisture, ensuring reliable performance in various environments. It is built to withstand harsh industrial conditions.
Applications
The applications for the Senko SI-310 are diverse and critical across several sectors:
- Chemical Manufacturing: The device plays a vital role in monitoring potentially harmful gases during chemical processes, helping to prevent accidents and ensure compliance with safety regulations.
- Semiconductor Production: In semiconductor facilities, precise gas detection is essential for maintaining product quality and ensuring worker safety.
- Environmental Monitoring: The SI-310 can be utilized in environmental monitoring applications to detect harmful gases that may impact air quality.
Senko SI-310 Specifications
The Senko SI-310 Fixed Gas Detector is designed to monitor specific gases such as hexafluorobutadiene, octafluorocyclopentene, difluoromethane, and fluoromethane with high precision, utilizing electrochemical sensors and offering customizable alarm thresholds for enhanced industrial safety.
| Size | 212mm(W) X 225mm(D) X 141.7mm(H) |
| Weight | 6.5Kg |
| Operating voltage | DC: 24V ± 10% |
| PoE: 36V~57V (Typical: 48V) | |
| Flow rate | 100 ~ 1,000 ml (Normal 300 ~ 500ml / min) |
| Power consumption | Approx. 15.0W @ +24VDC (Pyrolyzer Use 600mA@+24Vdc) |
| Measurement display | FND, gas concentration, flow rate, alarm, device faulty |
| Relay | Low Alarm, High Alarm, Fault Alarm (Rated 2.0A @ 30Vdc) |
| Analog Output signal | 4-20mA |
| Digital communication | RS-485, TCP Ethernet (PoE) |
| Sampling distance | Length of input gas tube: up to 30m (FEP tube) |
| Length of exhaust gas tube: up to 30m (FEP tube) | |
| Input/Output tube | 1/4” Teflon tube |
| Operating temperature | -40°C ~ 60°C |
| Certification | KCs: Ex db IIC T6 Gb |
| Control/Set | 4 Button & RS485 & Ethernet & Bluetooth |
| Warranty period of the device | 2 years |
| Warranty period of sensor cartridge | 1 year |
| Remote interface | Ethernet (PoE), RS-485, HART (Option) |
| Wiring | 4 to 20mA / DC power / Relay: up to 14 AWG / Ethernet: RJ-45 Cat.5E |
| Pressure range | 90 to 110KPa |
| Maximum sample flow | Max. 1,000 ml |
| Maximum sample pressure | 6KPa |
| Gas | Sensor | Range | A1 | A2 | Resolution |
| Hexafluorobutadiene | C₄F₆ | 0~40ppm | 10ppm | 20ppm | 1.5ppm |
| Octafluorocyclopentene | C₅F₈ | 0~40ppm | 5ppm | 10ppm | 2.0ppm |
| Difluoromethane | CH₂F₂ | 0~120ppm | 15ppm | 30ppm | 6.0ppm |
| Fluoromethane | CH₃F | 0~120ppm | 15ppm | 30ppm | 8.0ppm |
Buy the Senko SI-310 Fixed Gas Detector for effective gas monitoring in industrial settings. Its innovative sampling technology and user-friendly design enhance safety and compliance where hazardous gases are present.
Specifications
| Size | 212mm(W) X 225mm(D) X 141.7mm(H) |
| Weight | 6.5Kg |
| Operating voltage | DC: 24V ± 10% |
| PoE: 36V~57V (Typical: 48V) | |
| Flow rate | 100 ~ 1,000 ml (Normal 300 ~ 500ml / min) |
| Power consumption | Approx. 15.0W @ +24VDC (Pyrolyzer Use 600mA@+24Vdc) |
| Measurement display | FND, gas concentration, flow rate, alarm, device faulty |
| Relay | Low Alarm, High Alarm, Fault Alarm (Rated 2.0A @ 30Vdc) |
| Analog Output signal | 4-20mA |
| Digital communication | RS-485, TCP Ethernet (PoE) |
| Sampling distance | Length of input gas tube: up to 30m (FEP tube) |
| Length of exhaust gas tube: up to 30m (FEP tube) | |
| Input/Output tube | 1/4” Teflon tube |
| Operating temperature | -40°C ~ 60°C |
| Certification | KCs: Ex db IIC T6 Gb |
| Control/Set | 4 Button & RS485 & Ethernet & Bluetooth |
| Warranty period of the device | 2 years |
| Warranty period of sensor cartridge | 1 year |
| Remote interface | Ethernet (PoE), RS-485, HART (Option) |
| Wiring | 4 to 20mA / DC power / Relay: up to 14 AWG / Ethernet: RJ-45 Cat.5E |
| Pressure range | 90 to 110KPa |
| Maximum sample flow | Max. 1,000 ml |
| Maximum sample pressure | 6KPa |
| Gas | Sensor | Range | A1 | A2 | Resolution |
| Hexafluorobutadiene | C₄F₆ | 0~40ppm | 10ppm | 20ppm | 1.5ppm |
| Octafluorocyclopentene | C₅F₈ | 0~40ppm | 5ppm | 10ppm | 2.0ppm |
| Difluoromethane | CH₂F₂ | 0~120ppm | 15ppm | 30ppm | 6.0ppm |
| Fluoromethane | CH₃F | 0~120ppm | 15ppm | 30ppm | 8.0ppm |