Rated 0 out of 5
(0)
- True RMS measurement for accurate readings on non-linear signals
- 600 V CAT III safety rating for industrial protection
- 6,000-count digital display with bar graph visualization
- 400-hour battery life on a single 9V Alkaline battery
- Auto voltage range and Lo-Z capacitance function
- Continuity, diode test, and capacitance measurement modes
- Compact design at 167 x 84 x 46 mm for field use
Rated 0 out of 5
(0)
- Weight: 3 kg
- CATEGORY: Accessories
- RANGE: Multi
- VOLTAGE: 6000A
- CURRENT: 6000A
- MODEL: I17XX-FLEX6KIP/4PK
Rated 0 out of 5
(0)
- General specifications
- Maximum voltage between any terminal and earth ground: 1000 V
- Display (LCD): 4000 counts, updates 3/sec
- Battery type: 2 AA, NEDA 15A, IEC LR6
- Battery life: 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
- Temperature
Rated 0 out of 5
(0)
- General specifications
- Maximum voltage between any terminal and earth ground: 1000 V
- Display (LCD): 4000 counts, updates 3/sec
- Battery type: 2 AA, NEDA 15A, IEC LR6
- Battery life: 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
- Temperature
Rated 0 out of 5
(0)
- Accuracy Specifications
- Function: Range
- AC Volts (40 Hz to 500Hz) 1: 6.000 V 60.00 V 600.0 V
- DC Volts: 6.000 V 60.00 V 600.0 V
- AC Millivolts: 600.0 mV
- Diode Test 2: 2.000 V
Rated 0 out of 5
(0)
- General specifications
- Infrared spectral band: 8 μm to 14 μm (long wave)
- Operating temperature: -10 °C to 50 °C (14 °F to 122 °F)
- Storage temperature: -20 °C to 50 °C without batteries
- Relative humidity: 95 % non-condensing
- Safety: IEC 61010-1: Pollution Degree 2
Rated 0 out of 5
(0)
- Parameter: Range
- Voltage: 1000 V
- Voltage dips and swells: –
- Voltage transients: ±8 kVpk
- Voltage harmonics/interharmonics: 100 %
- THD on voltage: 100 %
Rated 0 out of 5
(0)
- Specifications
- Voltage DC: Accuracy 1
- Max. resolution: 0.1 mV
- Maximum: 1000 V
- Voltage AC: Accuracy 1
- Max. resolution: 0.1 mV
Rated 0 out of 5
(0)
- Parameter: Range
- Voltage: 1000 V
- Voltage dips and swells: –
- Voltage transients: ±8 kVpk
- Voltage harmonics/interharmonics: 100 %
- THD on voltage: 100 %
Rated 0 out of 5
(0)
- Parameter: Range
- Voltage: 1000 V
- Voltage dips and swells: –
- Voltage transients: ±8 kVpk
- Voltage harmonics/interharmonics: 100 %
- THD on voltage: 100 %
Rated 0 out of 5
(0)
- Specifications
- Test specifications: The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH.
- Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.
- The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
- Power-on test: The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
- Display range: 90 V to 264 V
Rated 0 out of 5
(0)
- Weight: 1 kg
- Category: Process Calibrator
- Range: Multi
- Voltage: 0‑30 V
- Current: 0‑24 mA
- Brand: Fluke
Rated 0 out of 5
(0)
- Specifications
- Temperature Range: -30°C to 350°C (-22°F to 662°F)
- Accuracy (Calibration geometry with ambient temperature 23°C ±2°C): ≥ 0°C
- ≥ -10°C to <0°C: ±2.0°C
- < -10°C: ±3.0°C
- ≥ 32°F: ±4.0°F or ±2.0% of reading, whichever is greater
Rated 0 out of 5
(0)
- Specifications
- Temperature Range: -30°C to 350°C (-22°F to 662°F)
- Accuracy (Calibration geometry with ambient temperature 23°C ±2°C): ≥ 0°C
- ≥ -10°C to <0°C: ±2.0°C
- < -10°C: ±3.0°C
- ≥ 32°F: ±4.0°F or ±2.0% of reading, whichever is greater
Rated 0 out of 5
(0)
- Battery Resistance / Strap Resistance 1: 3 mΩ
- 30 mΩ: 0.01 mΩ
- 300 mΩ: 0.1 mΩ
- 3000 mΩ: 1 mΩ
- VDC: 6 V
- 60 V: 0.01 V
Rated 0 out of 5
(0)
- Air pressure: Range / Resolution / Accuracy
- ±16 inH 2 O/ 0.001 inH 2 O/±1% + 0.01 inH 2 O
- ±400 mmH 2 O/ 0.1 mmH 2 O / ±1% + 0.1 mmH 2 O
- ±40 mbar /0.01 mbar / ±1% + 0.01 mbar
- ±0.6 psi / 0.0001 psi /±1% + 0.0001 psi
Rated 0 out of 5
(0)
- Weight: 0.75 kg
- CATEGORY: Accessories
- MODEL: TLK-225-1
- BRAND: Fluke
Rated 0 out of 5
(0)
- Weight: 0.625 kg
- CATEGORY: Accessories
- RANGE: 40 kV
- VOLTAGE: 40 kV
- MODEL: 80K-40
- BRAND: Fluke
Rated 0 out of 5
(0)
- General Specifications
- Maximum voltage applied between any terminal and earth ground or between any two terminals: 30 V
- Operating temperature: -10°C to 50°C
- Storage temperature: -30°C to 60°C
- Operating altitude: 2,000 m
- Storage altitude: 12,000 m
Rated 0 out of 5
(0)
- Technical Specifications
- Fluke 718 Series
- Measure pressure: (Internal sensor)
- Accuracy: 0.025% full scale
- Functions: Zero, min/max, hold, damp
- Dry air, non-corrosives only
Rated 0 out of 5
(0)
- Measurement Accuracy
- Voltage DC: 30.000 V
- 30.000 V: 0.02% + 2 counts (lower display)
- 100.00 mV: 0.02% + 2 counts
- -10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector)
- Current DC: 24.000 mA
Rated 0 out of 5
(0)
- Specifications
- Current measurement: Range
- Resolution: 0.001 mA
- Accuracy: 0.015% Rdg + 2 LSD
- Current sourcing: Range
- Accuracy: 0.015% Rdg + 2 LSD
Rated 0 out of 5
(0)
- Specifications
- Current measurement: Range
- Resolution: 0.001 mA
- Accuracy: 0.02% Rdg + 2 LSD
- Current sourcing: Range
- Accuracy: 0.025% Rdg + 2 LSD
Rated 0 out of 5
(0)
- Specifications
- Current measurement: Range
- Resolution: 1 mA
- Accuracy: 0.2% + 2 LSD (DC)
- Range: 0-30 mA
- Resolution: 0.001 mA
Rated 0 out of 5
(0)
- Low‑frequency range: 10 Hz to 1 000 Hz
- High‑frequency range: 4 000 Hz to 20 000 Hz
- 16‑bit A/D converter with 80 dB signal‑to‑noise ratio
- Resolution of 0.01 g and accuracy ±5% at 100 Hz
- Vibration limit up to 50 g peak (100 g peak‑peak)
- Supports Fluke Connect for real‑time data sharing
Rated 0 out of 5
(0)
- Input A and input B
- DC voltage (VDC)
- Ranges: 500 mV, 5 V, 50 V, 500 V, 750 V
- Accuracy: ±(0.5% +5 counts)
- Common mode rejection (CMRR): >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
- Full scale reading: 5000 counts
Rated 0 out of 5
(0)
- Electrical Specifications
- Power Supply
- Voltage range: 100 V to 500 V using safety plug input when powering from the measurement circuit
- 100 V to 240 V using standard power cord (IEC 60320 C7)
- Power consumption: Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
- Efficiency: ≥ 68.2% (in accordance with energy efficiency regulations)
Rated 0 out of 5
(0)
- Best accuracy for DC voltage: ±(0.3% + 1)
- Best accuracy for AC voltage: ±(2.0% + 2)
- Best accuracy for AC current: 2.5% + 2
- Best accuracy for DC current: 1.5% + 2
- Best accuracy for resistance: ±(0.5% + 1)
- Best accuracy for capacitance: ±(1.2% + 2)
- Best accuracy for frequency: ±(0.1% + 1)
Rated 0 out of 5
(0)
- True‑RMS AC bandwidth up to 100 kHz
- Logging memory up to 10,000 readings
- Optional infrared connector via Fluke ir3000 FC
- Battery life 100 h minimum, 200 h in logging mode
- Multiple on‑screen displays
- Auto/touch hold and hold functions
- Peak detection 250 µs
Rated 0 out of 5
(0)
- IP30 ingress protection with jaw closed
- Maximum voltage to earth ground: 1000 V
- Battery life: >15 hours (AA alkaline, 4 cells)
- Frequency range: 40 Hz to 1 kHz
- Refresh rate: 4 reads per second
- Operating temperature: –10 °C to +50 °C
- Data logging capacity: 32,760 measurements
Rated 0 out of 5
(0)
- 600 A range with 0.1 A resolution
- 2.0 % accuracy (45‑65 Hz) and 2.5 % accuracy (65‑400 Hz)
- 600 V AC/DC range, 0.1 V resolution, 1.5 % accuracy
- 600 kΩ resistance range, 0.1 Ω resolution, 1 % accuracy
- IP30 rating, FCC‑certified, 2 AA battery powered
- Maximum 1000 V between any terminal and earth
Rated 0 out of 5
(0)
- AC/DC voltage measurement up to 600 V rms or DC
- Earth bond resistance measurement up to 20 kΩ with 0.01 Ω resolution
- Insulation measurement range 0.01 MΩ to 2000 MΩ
- Auto‑discharge time <0.5 s for C ≤ 1 µF
- Operable with up to 1 µF capacitive load
- Battery powered with four AA batteries (NEDA 15A or IEC LR6)
- IP40 rating for dust protection
Rated 0 out of 5
(0)
- Infrared temperature range: –40 °C to 800 °C
- Infrared accuracy: ±1 % or ±1 °C (whichever is greater) for temperatures above 0 °C
- Thermocouple Type‑K range: –270 °C to 1372 °C
- D:S ratio: 50:1 for precise spot measurements
- Laser sighting: single‑point Class 2 (II) laser, 630‑670 nm
- Emissivity adjustment: 0.10 to 1.00 in 0.01 increments
Rated 0 out of 5
(0)
- AC current range: 3 mA to 60 A with multiple stepped ranges
- Resolution from 0.001 mA to 0.1 A for precise readings
- Accuracy ±(0.02 + 1 digit) across all ranges
- Digital 3300‑count LCD display with 4 Hz refresh
- Battery life >150 hours on 2 AA cells
- CAT III 600 V / CAT IV 300 V safety compliance
Rated 0 out of 5
(0)
- Jaw current range up to 999.9 A
- Flexible current probe up to 2500 A
- AC voltage field‑sense range 0–1000 V
- AC voltage test‑lead range 0–600 V
- DC voltage range 0–600 V
- mV DC range 0–500 mV
Bench Multimeters