Fluke 117 EUR True RMS Multimeter
Fluke 117 True-RMS Digital Multimeter — compact and precise for fast electrical testing.
- True-RMS up to 600 V with CAT III 600V safety rating.
- VoltAlert NCV and LoZ mode to eliminate ghost voltage.
- Commercial switchboards, HVAC, and facility maintenance in UAE.
- 100% genuine Fluke, warranty, fast Dubai stock, calibration on request.
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
Fluke 117 True-RMS Electrician’s Multimeter: Technical Overview & Applications
The Fluke 117 is a professional-grade True-RMS digital multimeter specifically engineered for electricians working in fast-paced commercial and residential environments. Certified to CAT III 600 V safety standards, this compact diagnostic instrument is built to operate safely inside demanding facilities, motor control centers (MCC), and distribution panels across UAE climate conditions.
What sets the 117 apart from general-purpose multimeters is its dual dedicated diagnostic features: integrated VoltAlert™ technology for rapid non-contact voltage screening and Auto-V/LoZ functionality to eradicate deceptive ghost voltages. For instance, when troubleshooting a dead commercial lighting circuit adjacent to live 400 V duct banks, a technician can instantly verify de-energization without swapping tools or reading false inductive pick-ups. Sourced directly through verified industrial supply lines in Dubai, every unit supplied by MME includes full serial number traceability, standard factory warranty, and optional local ISO/IEC 17025 calibration certification upon dispatch.
Who Needs the Fluke 117 in GCC Industrial Sectors?
Engineered for precision troubleshooting without bulk, this model is the field standard for:
- Commercial & Facility Electricians: Routine load balancing, branch circuit tracing, and breaker panel maintenance across commercial towers and malls.
- HVAC & Building Automation Technicians: Testing control relays, flame sensors, and run capacitors in high-ambient UAE rooftops.
- M&E / EPC Fit-Out Contractors: Rapid safety validation and continuity verifications during pre-commissioning phases.
- Switchgear & Panel Builders: Safe verification of primary terminations, busbar clearances, and auxiliary wiring.
Key Diagnostic Capabilities & Field Advantages
To speed up diagnostic workflows without compromising field safety, the instrument combines four critical features:
- VoltAlert™ Non-Contact Voltage Detection: Optical and acoustic indicators alert the operator to energized lines immediately when placed near conductors or outlets, eliminating the need to expose bare conductors.
- LoZ (Low Impedance) Input Mode: Standard high-impedance meters register ghost or stray voltages induced by parallel live cables; activating LoZ discharges capacitive coupling to ensure true zero readings.
- Auto-V Automatic Selection: The meter automatically detects whether the incoming signal is AC or DC voltage and sets proper measurement parameters without manual dial switching.
- True-RMS Accuracy on Non-Linear Loads: Essential for modern electrical setups where variable frequency drives (VFDs), LED drivers, and switching power supplies distort the AC wave profile.
Fluke 117 vs 115 vs 179: Choosing the Right GCC Diagnostic Meter
Selecting between the Fluke compact 11x series and the industrial-tier 170 series depends on your specific test environment, voltage thresholds, and required parameters:
| Feature / Specification | Fluke 117 (Electrician’s Standard) | Fluke 115 (Field Technician) | Fluke 179 (Industrial Heavy-Duty) |
|---|---|---|---|
| Primary Target | Commercial Electricians & Facility Teams | Field Service & Electronic Repair | Industrial Plant Maintenance & Utility |
| Safety Rating | CAT III 600 V | CAT III 600 V | CAT IV 600 V / CAT III 1000 V |
| Integrated VoltAlert™ (NCV) | Yes (Built-in) | No | No (Requires separate detector) |
| LoZ Ghost Voltage Elimination | Yes | No | No |
| Built-in Thermometer | No | No | Yes (Includes bead probe) |
| Current Measurement Range | 10.00 A AC/DC (20 A overload) | 10.00 A AC/DC (20 A overload) | 10.00 A AC/DC continuous |
| Display Counts & Backlight | 6000 counts / White LED | 6000 counts / White LED | 6000 counts / Backlit + Analog Bar |
| Typical GCC Use-Case | Commercial fit-outs, DB panels, HVAC | Bench testing, equipment repair | Substation panels, heavy industrial motors |
What’s Included in the Fluke 117 Factory Package?
When ordering the Fluke 117 True-RMS Multimeter from MME, the package includes:
- Fluke 117 True-RMS Multimeter: The core diagnostic instrument with integrated holster.
- Fluke TL75 Hard Point™ Test Lead Set: High-durability CAT III 1000 V / CAT IV 600 V rated test leads with protective lantern caps.
- Pre-Installed 9 V Alkaline Battery: Providing up to 400 hours of continuous operation (non-backlight).
- Fluke Holster: Integrated yellow protective rubber holster with built-in test lead holders.
- Quick Reference Guide & Safety Documentation: Multilingual user manual and official manufacturer compliance sheets.
Genuine Fluke 117 EUR Supply & Local Calibration Support in UAE
Sourcing test and measurement instruments through MME ensures:
- Guaranteed Originality: Clean supply chain verification to protect your projects against counterfeit instruments.
- Immediate Availability: In-stock items staged locally in Dubai for rapid logistics turnaround across Abu Dhabi, Sharjah, and Northern Emirates.
- Traceable Calibration: Optional third-party accredited calibration reports available prior to site delivery to meet DEWA, ADNOC, or municipal audit compliance.
Does the Fluke 117 read milliamps?
No. The Fluke 117 measures AC and DC current up to 10 A, but it does not feature a milliamp measurement range.
Does the Fluke 117 feature True RMS?
Yes. The Fluke 117 is a True RMS digital multimeter, ensuring accurate voltage and current measurements on non-linear loads.
What is the purpose of the Auto-V / LoZ function on the Fluke 117?
This low-impedance measurement mode presents a low impedance across the test leads to safely drain induced or “ghost voltages,” ensuring accurate voltage verification.
What is the difference between the Fluke 115 and the Fluke 117?
The Fluke 117 is designed specifically for commercial electricians and adds built-in non-contact voltage detection (VoltAlert), an Auto-V/LoZ low-impedance mode to prevent false readings from ghost voltages, and automatic AC/DC voltage selection compared to the Fluke 115.
Datasheet
Datasheet
User Manual
User Manual
Specifications
Specifications
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
|
| Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -40°C to +60°C | |
| Battery type | 9 volt Alkaline, IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
| AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max |
|
| DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max |
|
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
Reviews (0)
You must be logged in to post a review.

Bench Multimeters
Reviews
Clear filtersThere are no reviews yet.