Fluke 1732/EUS Energy Logger, EU/US version
- 16-bit synchronous sampling at 10.24 kHz
- Measures voltage, current, THD, power factor, and energy
- Supports 1-phase to 3-phase systems (delta, wye, IT configurations)
- Internal flash memory stores up to 10 logging sessions of 8 weeks
- WiFi and Bluetooth connectivity for Fluke Connect integration
- Voltage inputs up to 1000 V CAT III/600 V CAT IV
- Customer-replaceable Li-ion battery with up to 5.5 hours runtime
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 1732/EUS Energy Logger is a versatile power quality and energy logging solution designed for professionals who need comprehensive electrical system analysis. This EU/US version logger captures detailed waveform data and parameters across multiple circuit types, making it an essential tool for energy audits, troubleshooting, and compliance monitoring. With its ability to synchronize to mains frequency and sample at 10.24 kHz, the device provides accurate snapshots of power distribution networks, helping users identify inefficiencies and optimize performance.
Fluke 1732/EUS Key Features
Equipped with 4 voltage inputs and 3 current input channels, the Fluke 1732/EUS supports a wide range of circuit configurations including 1-phase, split phase, and three-phase systems such as delta, wye, and IT configurations. The logger features 16-bit resolution with synchronous sampling at 10.24 kHz, ensuring precise data capture of voltage, current, frequency, THD, power factor, and energy parameters. Internal non-user-replaceable flash memory stores typical 10 logging sessions of 8 weeks when set to 1-minute intervals. The device offers user-selectable averaging intervals from 1 second up to 30 minutes, with auxiliary measurements updated every 200ms. Connectivity options include USB-A for flash drive transfers, WiFi for remote access, and Bluetooth for reading auxiliary data from Fluke Connect 3000 series modules.
- 16-bit synchronous sampling at 10.24 kHz
- Measures voltage, current, THD, power factor, and energy
- Supports 1-phase to 3-phase systems (delta, wye, IT configurations)
- Internal flash memory stores up to 10 logging sessions of 8 weeks
- WiFi and Bluetooth connectivity for Fluke Connect integration
- Voltage inputs up to 1000 V CAT III/600 V CAT IV
- Customer-replaceable Li-ion battery with up to 5.5 hours runtime
- User-selectable averaging intervals from 1 second to 30 minutes
Who Needs the Fluke 1732/EUS?
Electrical engineers and maintenance technicians will find the Fluke 1732/EUS indispensable for conducting detailed power quality audits and identifying harmonic distortion issues in industrial and commercial facilities. Energy managers and building services teams can utilize the logger to track energy consumption patterns, verify power factor correction, and document demand charges over extended periods. The multi-circuit capability makes it suitable for complex installations including split-phase residential services and three-phase industrial plants. Facility managers responsible for energy reporting and compliance will appreciate the comprehensive data storage and the ability to generate detailed reports for stakeholders.
Field service electricians benefit from the logger’s rugged design and straightforward operation, allowing them to quickly capture voltage sags, swells, and transients that may disrupt sensitive equipment. Consulting engineers can use the collected data to justify energy efficiency upgrades and present findings to clients with confidence. The logger’s compatibility with Fluke Connect modules also enables remote monitoring, making it practical for distributed facilities or sites with limited on-site access.
Fluke 1732/EUS Applications
In manufacturing environments, the Fluke 1732/EUS can monitor drive efficiency, detect harmonic distortion from variable frequency drives, and ensure motors operate within specified parameters. Commercial building engineers use the logger to analyze lighting circuits, HVAC systems, and power distribution panels for energy waste and power quality issues. Utility companies and energy auditors rely on the device for load studies, demand-side management programs, and verifying utility rebate qualifications. Renewable energy installations benefit from the logger’s ability to track inverter performance and grid interaction characteristics.
Data center managers utilize the 1732/EUS to optimize power usage effectiveness (PUE) by monitoring rack power supplies and distribution units for inefficiencies. Building commissioning agents use the logger to verify that electrical systems meet design specifications and energy codes before handover. The logger’s extensive circuit support also makes it valuable for research institutions studying power electronics, motor drives, and energy storage systems where precise waveform analysis is required.
Why Buy Fluke 1732/EUS from mme-ae?
mme-ae ensures that every Fluke 1732/EUS Energy Logger comes with genuine manufacturer warranty and full factory support. Our team of technical specialists can assist with device setup, data interpretation, and configuration to match your specific measurement requirements. We stock the EU/US version ready for immediate shipment, eliminating wait times for your power quality monitoring projects. When you purchase from mme-ae, you benefit from our commitment to customer service, including post-sale support and access to Fluke’s extensive resource library.
Our streamlined ordering process and secure payment options mean you can focus on your analysis rather than logistics. We understand the urgency of electrical testing and strive to provide fastest delivery across the UAE and GCC regions. Trust mme-ae for authentic Fluke products and the expertise to help you get the most from your investment in electrical measurement technology.
Fluke 1732/EUS Specifications
| Electrical Specifications | |
| Power Supply | |
| Voltage range | 100 V to 500 V using safety plug input when powering from the measurement circuit |
| 100 V to 240 V using standard power cord (IEC 60320 C7) | |
| Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) |
| Efficiency | ≥ 68.2% (in accordance with energy efficiency regulations) |
| Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input |
| Mains power frequency | 50/60 Hz ±15% |
| Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
| On-battery runtime | Four hours in standard operating mode, up to 5.5 hours in power saving mode |
| Charging time | < 6 hours |
| Data Acquisition | |
| Resolution | 16-bit synchronous sampling |
| Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency |
| Input signal frequency | 50/60 Hz (42.5 to 69 Hz) |
| Circuit types | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies) |
| Data storage | Internal flash memory (not user replaceable) |
| Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹ |
| ¹The number of possible logging sessions and logging period depends on user requirements. | |
| Basic Interval | |
| Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
| Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms |
| Demand Interval (Energy Meter Mode) | |
| Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |
| Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
| Standards Compliance | |
| Power | IEEE 1459 |
| Interfaces | |
| USB-A | File transfer via USB flash drive, firmware updates Max. current: 120 mA |
| WiFi | File transfer and remote control via direct connection or WiFi infrastructure |
| Bluetooth | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option) |
| USB-mini | Data download device to PC |
| Voltage Inputs | |
| Number of inputs | 4 (3 phases and neutral) |
| Maximum input voltage | 1000 Vrms, CF 1.7 |
| Input impedance | 10 MΩ |
| Bandwidth (-3 dB) | 42.5 Hz – 3.5 kHz |
| Scaling | 1:1 and variable |
| Measurement category | 1000 V CAT III/600 V CAT IV |
| Current Inputs | |
| Number of inputs | 3, mode selected automatically for attached sensor |
| Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 |
| Rogowski coil input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
| Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12″ |
| 3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24″ | |
| 6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36″ | |
| 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |
| Bandwidth (-3 dB) | 42.5 Hz – 3.5 kHz |
| Scaling | 1:1 and variable |
| Auxiliary Inputs | |
| Number of inputs | 2 |
| Input range | 0 to ±10 V dc, 1reading/s |
| Scale factor (available 2014) | Format: mx + b (gain and offset) user configurable |
| Displayed units (available 2014) | User configurable (7 characters, for example, °C, psi, or m/s) |
| Wireless Connection | |
| Number of inputs | 2 |
| Supported modules | Fluke Connect® 3000 series |
| Acquisition | 1 reading/s |
| Environmental Specifications | |
| Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) |
| Operating humidity | 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH |
| 30 °C to 40 °C (86 °F to 104 °F) max. 75% RH | |
| 40 °C to 50 °C (104 °F to 122 °F) max. 45% RH | |
| Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
| Storage altitude | 12,000m |
| Enclosure | IP50 in accordance with EN60529 |
| Vibration | MIL-T-28800E, Type 3, Class III, Style B |
| Safety | IEC 61010-1 |
| IEC Mains Input: Overvoltage Category II, Pollution Degree 2 | |
| Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 | |
| IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V | |
| Electromagnetic compatibility | EN 61326-1: Industrial CISPR 11: Group 1, Class A |
| Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |
| USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |
| Temperature coefficient | 0.1 x accuracy specification/°C |
| General Specifications | |
| Color LCD display | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel |
| Warranty | Instrument and power supply: Two-years (battery not included) |
| Accessories: one-year | |
| Calibration cycle: two-years | |
| Dimensions | Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in) |
| Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in) | |
| Instrument with power supply attached: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in) | |
| Weight | Instrument: 1.1 kg (2.5 lb) |
| Power supply: 400 g (0.9 lb) | |
| Tamper protection | Kensington lock slot |
| i17xx-flex 1500 12″ Flexible Current Probe Specifications | |
| Measuring range | 1 to 150 A ac/10 to 1500 A ac |
| Nondestructive current | 100 kA (50/60 Hz) |
| Intrinsic error at reference condition* | ±0.7% of reading |
| Accuracy 173x + iFlex | ±(1% of reading + 0.02% of range) |
| Temperature coefficient over operating temperature range | 0.05% of reading/°C 0.09% of reading/°F |
| Working voltage | 1000 V CAT III, 600 V CAT IV |
| Probe cable length | 305 mm (12 in) |
| Probe cable diameter | 7.5 mm (0.3 in) |
| Minimum bending radius | 38 mm (1.5 in) |
| Output cable length | 2 m (6.6 ft) |
| Weight | 115 g |
| Probe cable material | TPR |
| Coupling material | POM + ABS/PC |
| Output cable | TPR/PVC |
| Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) |
| Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) |
| Relative humidity, operating | 15% to 85% non-condensing |
| IP rating | IEC 60529:IP50 |
| Warranty | One-year |
* Reference condition:
|
|