Fluke 1742/30/EUS Power Quality Logger with 60 cm 3,000A iflex
- 60 cm 3,000A flexible current transformer
- 16-bit synchronous sampling at 10.24 kHz
- Measures harmonics up to 50th order
- Stores 20 logging sessions internally
- Li-ion battery with 4-hour runtime
- Supports 1-phase and 3-phase circuit types
- Compliant with IEC 61000-4-30 standards
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
Memory vs sessions vs events (Fluke 1740 series): Internal flash typically stores about 20 logging sessions of 4 weeks at 1-minute intervals. Event capacity (e.g., dips/swells/inrush) is separate from session duration—longer sessions reduce remaining room for high event counts. Warm-up / low-temperature notes follow Fluke operating specs (instrument vs battery limits).
The Fluke 1742/30/EUS Power Quality Logger is a precision instrument designed for engineers and technicians who need to capture and analyze power quality issues across diverse electrical networks. This EUS-version device records voltage, current, frequency, and harmonic distortion with 16-bit resolution, providing detailed data for troubleshooting intermittent faults, verifying compliance, and optimizing energy efficiency. Its flexible current transformer and comprehensive logging capabilities make it suitable for industrial facilities, commercial buildings, and renewable energy systems where accurate power monitoring is critical.
Fluke 1742/30/EUS Key Features
Equipped with a 60 cm 3,000A iFlex current transformer, the Fluke 1742/30/EUS offers enhanced measurement flexibility for large conductors without breaking the circuit. The logger captures 16-bit synchronous samples at 10.24 kHz, synchronized to the mains frequency, ensuring accurate waveform capture for power quality analysis. It supports a wide range of circuit configurations including 1-phase, split phase, and various 3-phase arrangements such as delta and wye configurations, including IT systems. The internal flash memory stores typical 20 logging sessions of four weeks at one-minute intervals, allowing extended monitoring without data overwrite concerns.
- 16-bit synchronous sampling at 10.24 kHz
- Measures harmonics up to 50th order with configurable grouping
- Supports 1-phase, 3-phase delta, wye, and IT systems
- Internal memory for 20 sessions of 4 weeks at 1-minute intervals
- 60 cm 3,000A iFlex current transformer included
- Voltage range 100 V to 500 V from safety plug input
- Compliant with IEC 61000-4-30 for flicker and harmonics
- User-selectable averaging intervals from 1 second to 30 minutes
Who Needs the Fluke 1742/30/EUS?
Electrical engineers and maintenance technicians responsible for power system reliability will find the Fluke 1742/30/EUS indispensable for diagnosing voltage sags, swells, and harmonic distortion that can damage sensitive equipment. Energy managers and facility operators use the device to conduct energy audits, identify power factor penalties, and track consumption patterns over extended periods. Consultants and auditors benefit from the logger’s ability to generate detailed reports on power quality parameters, helping clients meet regulatory standards and reduce operational costs through informed corrective actions.
Field service teams appreciate the portable design and flexible current transformer, which allows quick clamp-on measurements on existing installations without disrupting power flow. The device’s intuitive interface and comprehensive parameter set make it suitable for both routine preventive maintenance and detailed investigative analysis of power quality events such as dips, swells, and interruptions.
Buyers and procurement officers specifying power monitoring equipment for utility-scale projects or industrial retrofits will appreciate the logger’s wide input voltage range and compatibility with various circuit types. The EUS version ensures compliance with regional standards, making it a reliable choice for projects across the Gulf Cooperation Council region and beyond.
Fluke 1742/30/EUS Applications
In industrial manufacturing plants, the Fluke 1742/30/EUS monitors variable frequency drives and motor circuits to identify harmonic distortion that can cause overheating and premature equipment failure. The logger captures transient events and inrush currents, providing data for load studies and equipment sizing. For building management systems, the device tracks power quality across lighting circuits and HVAC equipment, helping facility managers reduce energy waste and extend the lifespan of electrical distribution components.
Renewable energy installations, including solar and wind farms, benefit from the logger’s ability to measure grid compliance parameters and analyze power quality from inverter outputs. The Fluke 1742/30/EUS is also suitable for data center infrastructure monitoring, where power reliability is paramount, and even minor voltage variations can impact server performance. Utility companies use the device for field measurements and validation of power quality standards on distribution networks.
Why Buy Fluke 1742/30/EUS from mme-ae?
When you purchase the Fluke 1742/30/EUS from mme-ae, you are choosing genuine Fluke instruments supported by Mohammad Mahdi Electronics’ commitment to customer satisfaction. Our team provides product expertise to help you select the right power quality logger for your specific application requirements, ensuring you receive a device that meets your measurement needs from day one. We understand the importance of minimal downtime, which is why we prioritize efficient order processing and reliable delivery across the UAE.
Our after-sales support includes assistance with device setup, data export, and interpretation of power quality reports, helping you maximize the value of your investment. We stock genuine Fluke accessories and replacement parts, so your logger remains operational throughout its lifecycle. Trust MME for authentic products, technical support, and the peace of mind that comes with buying from MME, MME of genuine Fluke instruments.
Fluke 1742/30/EUS Specifications
| Electrical Specifications | |
| Power Supply | |
| Voltage range | 100 V to 500 V using safety plug input when powering from the measurement circuit |
| 100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7) | |
| Power consumption | Maximum 50 VA (max. 15 VA when powered using MA-C8 adapter) |
| Efficiency | ≥ 68.2% (in accordance with energy efficiency regulations) |
| Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input |
| Mains power frequency | 50/60 Hz ±15% |
| Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
| On-battery runtime | Typically 4 hours |
| Charging time | < 6 hours |
| Data Acquisition | |
| Resolution | 16-bit synchronous sampling |
| Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency |
| Input signal frequency | 50/60 Hz (42.5 to 69 Hz) |
| Circuit types | 1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies) |
| Data storage | Internal flash memory (not user replaceable) |
| Memory size | Typical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events |
| Basic Interval | |
| Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
| Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms) |
| Demand Interval (Energy Meter Mode) | |
| Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |
| Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
| Power Quality Measurements | |
| Measured parameter | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation |
| Averaging interval | 10 min for all parameters 2 hrs (long term Flicker PLT) 150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT) |
| Individual harmonics | 2nd to 50th harmonic Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only |
| Interharmonics | 1st to the 50th interharmonic |
| Total harmonic distortion | Calculated on 50 voltage harmonics |
| Events | Voltage: dips, swells, interruptions, current: inrush current 1748: mains signaling, transients (low frequency) |
| Triggered recordings | RMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1/2 according to IEC 61000-4-30) |
| Waveform of voltage and current up to 200 ms, 10/12 cycles | |
| Mains signaling: 10/12 cycle RMS recording of the configured frequencies up to 120s | |
| Inrush | RMS profile based on 1/2 cycle RMS steady state triggering |
| Flicker | In accordance with IEC 61000-4-15 and IEEE 1453 |
| Mains signaling | Two user defined frequencies up to 3 kHz |
| PQ Health | Summarizes power quality measurements in one table. Detailed data available for each parameter |
| EN 50160 | Compliance with standard |
| Programmable PQ limits | Enables user defined limits for local standards compliance |
| Standards Compliance | |
| Harmonics | IEC 61000-4-7: Class 1 |
| IEEE 519 (short time and very short time harmonics) | |
| Power quality | IEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device) |
| Power | IEEE 1459 |
| Power quality compliance | EN 50160 |
| Safety | General: IEC 61010-1: Pollution Degree 2 |
| Measurement: IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V | |
| Power Supply: Overvoltage Category IV, Pollution Degree 2 | |
| Li-ion Battery: IEC 62133 | |
| Interfaces | |
| USB-A | File transfer via USB flash drive, firmware updates, max. supply current: 120 mA |
| Wi-Fi (free with product registration) | File transfer and remote control via direct connection or Wi-Fi infrastructure |
| Bluetooth | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or Wi-Fi/BLE adapter, check for availability) |
| USB-mini | Data download device to PC |
| Voltage Inputs | |
| Number of inputs | 4 (3 phases referenced to neutral) |
| Maximum input voltage | 1000 Vrms, CF 1.7 |
| Input impedance | 10 MΩ |
| Bandwidth | 42.5 Hz to 3.5 kHz |
| Scaling | 1:1 and variable |
| Measurement category | 1000 V CAT III/600 V CAT IV |
| Current Inputs | |
| Number of inputs | 4 (3 phases and neutral), mode selected automatically for attached sensor |
| Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 |
| Rogowski coil input: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4 all at nominal probe range | |
| Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 IP 24 |
| 3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 IP 24 | |
| 6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 IP 36 | |
| 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |
| Bandwidth | 42.5 Hz – 3.5 kHz |
| Scaling | 1:1 and variable |
| Auxiliary Inputs | |
| Number of inputs | 2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously) |
| Input range | 0 to ± 10 V dc, or 0 to ± 1000 V dc (with optional adapter), 1 reading/s |
| Scale factor | Format: mx + b (gain and offset) user configurable |
| Displayed units | User configurable (7 characters, for example, °C, psi, or m/s) |
| Wireless Bluetooth connection (check for availability) | |
| Number of inputs | 2 |
| Supported modules | Fluke Connect® 3000 series |
| Acquisition | 1 reading/s |
| Environmental Specifications | |
| Operating temperature | -25 °C to +50 °C (-13 °F to 122 °F)1 |
| Storage temperature | Without battery: -25 °C to +60 °C (-13 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F) |
| Operating humidity | IEC 60721-3-3: 3K6: |
| -25 °C to +30 °C (-13 °F to +86 °F): ≤ 100 % | |
| 40 °C (104 °F): 55 % | |
| 50 °C (122 °F): 35 % | |
| Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
| Storage altitude | 12,000 m |
| Enclosure | IEC 60529: IP50 |
| IEC 60529: IP65 with IP65 rated voltage connector | |
| Vibration | IEC 60721-3-3 / 3M2 |
| Electromagnetic compatibility (EMC) | EN 61326-1: Industrial CISPR 11: Group 1, Class A |
| IEC 61000-6-5 Power station environment | |
| Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |
| USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |
| General Specifications | |
| Warranty | Two-years (battery not included) |
| Accessories: one-year | |
| Calibration cycle: two-years | |
| Dimensions | 23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in) |
| Weight | Instrument: 1 kg (2.2 lb) |
| Tamper protection | Accept securing cables (max. Φ 6mm) |
| 1Warm up the product to -10 °C (+14 °F) before you power the unit on | |
| i17XX-FLEX1.5KIP Flexible Current Probe Specifications | |
| Measuring range | 1 to 150 A ac/10 to 1500 A ac |
| Probe cable length | 610 mm (24 in) |
| Probe cable diameter | 7.5 mm (0.3 in) |
| Weight | 170 g (0.38 lb) |
| Minimum bending radius | 38 mm (1.5 in) |
| Nondestructive current | 100 kA (50/60 Hz) |
| Temperature coefficient over operating temperature range |
0.05 % of reading/°C (0.028 % of reading/°F) |
| Working voltage | 1000 V CAT III, 600 V CAT IV |
| Output cable length | 2.0 m (6.5 ft) |
| Probe cable material | TPR |
| Weight | 115 g |
| Probe cable material | TPR |
| Coupling material | POM + ABS/PC |
| Output cable | TPR/PVC |
| Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) |
| Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) |
| Relative humidity, operating | 15% to 85% non-condensing |
| IP rating | IEC 60529: IP65 |
| Warranty | One-year |
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.
Bench Multimeters
Reviews
Clear filtersThere are no reviews yet.