Hioki 3504 C HiTESTER
Short Description:
HIOKI C HiTESTER 3504 Key Features
- High speed measurement of 2ms
- Supports C measurements with voltage dependency characteristics through the use of constant voltage testing (CV)
- Model 3504-60 can detect contact failure on all 4 terminals for increased reliability
HIOKI C HiTESTER 3504
Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The 3504 series are dual-band capacitance meters suited for large-capacitance MLCC inspections using a constant voltage.
Constant-voltage measurement with an analog measurement time of 1 ms (1 kHz);
ideal for measurement of high-capacitance MLCCs
• Constant-voltage measurement of high capacitance values up to 1.45 mF (120 Hz, 500 mV)
• Model 3504-60 provides four-terminal contact checking.
- The BIN function on the 3504-60/-50 is ideal for sorting machines
- Model 3504-40 offers high speed and affordability, perfect for integrating into taping machines
- In all models, contact error is constantly monitored during measurement, contributing to increased yield
HIOKI C HiTESTER 3504 SPECIFICATION:
- Measurement parameters: C (capacitance), D (loss coefficient tan δ)
- Measurement range :C: 0.9400 pF to 20.0000 mF, D: 0.00001 to 1.99999
- Basic accuracy : (Typ.) C: ±0.09 % rdg. ±10 dgt., D: ±0.0016
- Measurement frequency: 120 Hz, 1 kHz
- Output impedance: 5Ω (In open terminal voltage mode outside of the CV measurement range)
- Display: LED (six digits, full-scale count depends on measurement range)
- Measurement time: 2 ms (Typ. value. Depends on measurement configuration settings)
- Power supply: Selectable from 100, 120, 220, or 240 V AC ±10 %, 50/60 Hz, 110 VA max.
- Dimensions and mass: 260 mm (10.24 in) W × 100 mm (3.94 in) H × 220 mm (8.66 in) D, 3.8 kg(134.0 oz)
- Accessories : Power cord ×1, Instruction manual ×1, Spare fuse ×1
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Hioki 3504 C HiTESTER
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
EXTECH LCR200 Passive Component LCR Meter
Rated 5.00 out of 5
In stock
Rebecca –
It is very practical