-17%Hot
Kyoritsu KEW 4105A Earth Tester
Short Description:
Kyoritsu Earth Testers KEW 4105AÂ Key Features :
• In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
• The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 60529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
Product purchase
AED 1,305 Original price was: AED 1,305.AED 1,079Current price is: AED 1,079. (excl.VAT)
11
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Buy Kyoritsu Earth Testers KEW-4105A
kyoritsu Kew 4105a earth resistance tester is an earth resistance tester for testing power distribution lines, in-house wiring systems, electrical appliances, etc. kyoritsu digital earth tester 4105a also has an earth voltage range for earth voltage measurement. Designed to safety standard IEC 61557.
Dust and drip-proof construction in conformity with IEC 60529 (IP54). Measurement can be made even under adverse weather conditions. Large, easy-to-read LCD digital display. A simplified measurement probe has a structure in that both the alligator clip and the test bar are available. Warns when earth resistance of auxiliary earth spikes exceeds the permissible limit.
kyoritsu digital earth tester kew 4105a Features
- Â Dust and drip proof.(designed to IEC 529 IP54)
- Â In addition to the facility for precision measurement, test leads for a simplified two-wire measuring system are also supplied as standard accessories. (The unit can be hung from the neck for simplified measurement)
- Designed to meet the IEC61010-1 safety standard.
- Capable of measuring earth voltage.
- Automatic warning when the resistance of auxiliary earth spikes is in excess of tolerance.
- Small and lightweight. Shock-resistant new case material.
- 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
Frequency Asked Questions
what is Earth Resistance Tester?
The Earth Resistance Tester is designed to measure the resistance of the object being tested. The Earth Resistance Tester is an instrument that measures the electric field strength between two points on a conductor. The Earth Resistance Tester can be used to detect faults in power cables, underground cables, and overhead cables. It is also used to test insulation materials and also for testing insulation systems such as lightning arresters and surge arresters. The Earth Resistance Testers are available in various ranges depending on the application or purpose for which they will be used. for kew 4105a price please contact us.
How to Use an Earth Tester?
- Step 1 Locate the grounding rods outside of your home. Look for a metal pole that goes into the ground and has a wire running to your house. The bars are usually located near the foundation of your home. Disconnect the ground wire from the stick.
- Step 2 Insert two grounding probes into the ground parallel to your grounding rod. Place one probe 65 feet from the ground rod and the second probe 33 feet from the first probe (98 feet from the ground rod).
- Step 3 Attach the ground tester leads to the ground rods. The red wire connects to the outdoor probe, the white wire to the indoor probe, and the blue (or green) wire to the ground rod.
- Step 4 Turn on the ground tester and press start. Digital ground testers provide a resistance measurement. Make a note of the number.
- Step 5 Disconnect the probes and move the indoor probe three to nine feet closer to the grounding rod. Test the resistance again. If the result is within 30 percent of the first measurement, your test is complete. Otherwise, move the probes further away from the ground rod until you get two readings within 30 percent of each other. Note the distances you used for your readings.
- Step 6 Repeat resistance checks at least once a year. If the resistance increases more than 20 percent from your original reading, you should replace your ground bar.
more information about kyoritsu 4105a
to download the Kyoritsu Earth Tester 4105a manual and Kyoritsu 4105a datasheet click on the datasheet tab and for the earth resistance tester Kyoritsu model 4105a manual click on the manual tab also for the Kyoritsu Earth Tester 4105a price visit our website. if you are looking for a similar product visit Kyoritsu 4105DL.
Looking for the best deal on the Kyoritsu 4105A? Our site offers competitive pricing on this reliable earth tester. Compare the Kyoritsu 4105A price with other models to find the best Kyoritsu earth tester price.
kyoritsu digital earth tester KEW-4105A Specifications:
- Measuring range :0 – 200 V AC (50,60Hz)
- Display range: 0.0 – 199.9 V
- Accuracy: ±1%rdg±4dgt
- Overload protection: Earth resistance: 280V AC (10 seconds), Earth voltage: 300V AC (1 minute)
- Applicable Standards: IEC 61010-1 CAT â…¢300 V Pollution degree 2, IEC 61010-2-030, IEC 61557-1, -5, IEC 60529 (IP54)
- Power source :R6(AA)(1.5V) × 6
- Dimensions :105(L) × 158(W) × 70(D) mm (including case lid)
- Weight: Approx. 550g (including batteries and case lid)
- Accessories: 7095A (Earth resistance test leads [red-20m, yellow-10m, green-5m/1 set]),7127B (Simplified measurement probe),,8032 (Auxiliary earth spikes[2 spikes/1 set]),9121 (shoulder strap),9084 (Soft case), R6(AA) × 6, Instruction manual
Specifications
Technical Specifications
Parameter | 20Ω | 200Ω | 2000Ω |
---|---|---|---|
Measuring Range | 0.00 – 1999Ω | ||
Display Range | 0.00 – 19.99Ω | 0.0 – 199.9Ω | 0 – 1999Ω |
Accuracy | ±2% rdg + 0.1 Ω | ±2% rdg + 3 dgt | |
Earth Voltage Measurement | |||
Measuring Range | 0 – 200 V AC (50/60Hz) | ||
Display Range | 0.0 – 199.9 V | ||
Accuracy | ±1% rdg + 4 dgt | ||
Overload Protection | Earth resistance: 280V AC (10 seconds) | Earth voltage: 300V AC (1 minute) | |
Applicable Standards | IEC 61010-1 CAT III 300 V Pollution degree 2, IEC 61010-2-030, IEC 61557-1,5, IEC 60529 (IP54) | ||
Power Source | R6 (AA) (1.5V) × 6 | ||
Dimension | 105(L) × 158(W) × 70(D) mm (including case lid) | ||
Weight | Approx. 550g (including batteries and case lid) | ||
Accessories | 7095A (Earth resistance test leads (Red 20m, Yellow 10m, Green 5m/1set)), 7127B (Simplified measurement probe), 8032 (Auxiliary earth spikes[2 spikes/1set]), 9121 (shoulder strap), 9084 (Carrying case), R6(AA) × 6, Instruction manual | ||
Optional Accessories | 7245A (Precision measurement cord set), 8259 (Adapter for measurement terminal), 9165 (Carring case [Hard]) |
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Kyoritsu KEW 4105A Earth Tester
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Ilyas –
Is it available?