Kyoritsu KEW8035 Non-contact Safety Phase Indicator
The Kyoritsu KEW8035 is a testament to innovation in electrical testing. It offers a safer, more efficient method for phase sequence detection. Its non-contact functionality, user-friendly features, and adherence to stringent safety standards make it an essential instrument for electrical professionals seeking accuracy and safety in their work.
- The insulated alligator clips can clip insulated cables from φ2.4 to 30mm
- Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones
- Wide measuring range for 3 phase installations from 70 to 1000V AC
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Buy Kyoritsu KEW8035
The Kyoritsu KEW8035 Non-Contact Safety Phase Indicator introduces a groundbreaking approach to phase sequence testing. By eliminating the need for direct contact with live conductors, it enhances safety and efficiency in electrical diagnostics, making it an indispensable tool for professionals in the field.
Key Features
Designed with precision and user safety in mind, the KyoritsuKEW8035 offers a suite of features that set it apart:
- Non-Contact Operation: The KEW8035 utilizes electrostatic induction to detect phase sequences without direct contact, reducing the risk of electrical hazards.
- Wide Voltage Range: Capable of measuring 3-phase AC voltages from 70V to 1000V, accommodating a broad spectrum of industrial applications.
- Versatile Cable Compatibility: The insulated crocodile clips can securely attach to insulated cables ranging from 2.4mm to 30mm in diameter, ensuring adaptability across various setups.
- Clear Visual and Audible Indicators: Equipped with bright LEDs and distinct buzzer sounds to indicate phase rotation direction, facilitating quick and accurate assessments.
- Enhanced Visibility: A brightness switch improves LED visibility in dimly lit environments, ensuring reliable readings under all conditions.
- Magnetic Mounting: A built-in magnet enables the device to be affixed to metal panels, providing hands-free operation and convenience during testing.
- Robust Safety Standards: Complies with international safety standards, including IEC 61010-1 CAT IV 600V and CAT III 1000V, underscoring its reliability and safety in high-voltage environments.
Kyoritsu KEW8035 Specification
The Kyoritsu KEW8035 Non-contact Safety Phase Indicator employs an electrostatic induction detection method with a voltage range of 70 to 1000V AC.
| Functions | Phase rotation (Clockwise or Counter Clockwise), Presence of open phase |
| Detection method | Electrostatic induction |
| Measuring voltage range | From 70 to 1000V AC phase to phase (sine wave, continuous input) |
| Clamp diameter range | From Ø2.4 to 30mm insulated cables |
| Measuring frequency range | 45 to 66Hz |
| Phase rotation | Clockwise: Green arrow LEDs “rotate” in clockwise, Green symbol “CW” lits, Intermittent buzzer |
| Counter Clockwise: Red arrow LEDs “rotate” in counter-clockwise, Red symbol “CCW” lits, continuous buzzer | |
| Visual indication | LEDs with Super brightness function |
| Battery voltage warning | Power LED blinks if battery voltage is too low. |
| Test leads | Double insulated cables, length Approx. 70cm |
| Colors leads | L1(U): RedL2(V): WhiteL3(W): Blue |
| Applicable standards | IEC 61010-1 CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree2 |
| IEC 61326-1, IEC 61557-1, -7 | |
| Operating temperature and humidity range | -10 to 50ºC, relative humidity 80% or less (no condensation) |
| Storage temperature and humidity range | -20 to 60ºC, relative humidity 80% or less (no condensation) |
| Power supply (DC battery) | LR6(AA)(1.5V) ×4 |
| * Continuous use: Approx. 100 hours (Auto power off in about 10 min.) | |
| Dimension | 112(L) × 61(W) × 36(D) mm |
| Weight | Approx. 380g |
| Accessories | 9096 (Carrying case) |
| LR6(AA) × 4, Instruction manual |
Buy the Kyoritsu KEW8035 Non-contact Safety Phase Indicator, a significant advancement in electrical testing. It offers a safer and more efficient method for detecting phase sequences. With its non-contact capabilities, user-friendly design, and compliance with strict safety standards, this tool is essential for electrical professionals who prioritize accuracy and safety in their work.
Specification
| Functions | Phase rotation (Clockwise or Counter Clockwise), Presence of open phase |
| Detection method | Electrostatic induction |
| Measuring voltage range | From 70 to 1000V AC phase to phase (sine wave, continuous input) |
| Clamp diameter range | From Ø2.4 to 30mm insulated cables |
| Measuring frequency range | 45 to 66Hz |
| Phase rotation | Clockwise: Green arrow LEDs “rotate” in clockwise, Green symbol “CW” lits, Intermittent buzzer |
| Counter Clockwise: Red arrow LEDs “rotate” in counter-clockwise, Red symbol “CCW” lits, continuous buzzer | |
| Visual indication | LEDs with Super brightness function |
| Battery voltage warning | Power LED blinks if battery voltage is too low. |
| Test leads | Double insulated cables, length Approx. 70cm |
| Colors leads | L1(U): RedL2(V): WhiteL3(W): Blue |
| Applicable standards | IEC 61010-1 CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree2 |
| IEC 61326-1, IEC 61557-1, -7 | |
| Operating temperature and humidity range | -10 to 50ºC, relative humidity 80% or less (no condensation) |
| Storage temperature and humidity range | -20 to 60ºC, relative humidity 80% or less (no condensation) |
| Power supply (DC battery) | LR6(AA)(1.5V) ×4 |
| * Continuous use: Approx. 100 hours (Auto power off in about 10 min.) | |
| Dimension | 112(L) × 61(W) × 36(D) mm |
| Weight | Approx. 380g |
| Accessories | 9096 (Carrying case) |
| LR6(AA) × 4, Instruction manual |