meggar DELTA4000-12 KV INSULATION DIAGNOSTIC SYSTEM Series key features:

  • Power factor test set
  • Automatic and manual operation
  • Accurate and repeatable measurement results with high noise suppression
  • Lightweight, rugged two-piece design
  • New built-in intelligent temperature correction (patent pending)
  • New automatic voltage dependence detection (patent pending)

Product purchase

SKU: 4161 Categories: ,
Brand:Megger

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

12 People watching this product now!

Terms of sending goods ›

  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

Meggar DELTA4000 Series

The Megger DELTA4000 Series-12 KV Insulation Diagnostic System is an innovative, high-performance solution tailored for the efficient and accurate assessment of electrical insulation in a variety of high-voltage applications. Designed as a versatile, automatic 12 kV insulation power factor/tan delta test set, the DELTA4000 is essential for professionals in the electrical power industry who are responsible for the upkeep of transformers, bushings, circuit breakers, cables, lightning arresters, and rotating machines.

Enhanced Diagnostic Capabilities

A standout feature of the DELTA4000 is its ability to conduct both traditional power frequency (50/60 Hz) testing and 1 Hz power factor/tan delta testing. The incorporation of 1 Hz testing allows for enhanced power frequency assessments, significantly improving maintenance planning by reducing reliance on historical data and proprietary databases. This dual testing capability ensures comprehensive condition assessment and aids in the early detection of potential insulation failures.

Meggar DELTA4000 Series-12 KV Insulation Diagnostic System specifications:

  • input Power
    90 – 264 V 45 – 66 Hz
    16 A max
    No loss in performance when used with a portable generator
  • Output Voltage
    0 to 12 kV, continuously adjustable
  • Test Frequency Range
    45-70 Hz (12 kV)
    15-400 Hz (4 kV)
    1-505 Hz (250V)
    0.0001 Hz maximum resolution
  • Output Power
    3.6 kVA

catalog

Data Sheet

specifications

 

Specification Details
Input Power 90 – 264 V, 45 – 66 Hz, 16 A max
No loss in performance when used with portable generator
Output Voltage 0 to 12 kV, continuously adjustable
Test Frequency Range 45-70 Hz at 12 kV
15-400 Hz at 4 kV
1-505 Hz at 250V
0.0001 Hz maximum resolution
Output Power 3.6 kVA

 