Megger EGIL200 Circuit Breaker Analyser
Looking to buy a Megger EGIL200? Discover great prices and deals in Dubai, UAE. Elevate your work with this cutting-edge tool today!
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Megger EGIL200 Circuit Breaker Analyser
The Megger EGIL200 circuit breaker analyser was designed to meet the market demand for a reasonably priced, mid-range analyser that is quick and straightforward to operate. The focus during its development was on simplicity, significantly reducing the time needed to set up for measurements. It features a quick test mode where all necessary settings are readily accessible on a single screen, making it easy to start tests immediately.
This tool is particularly effective for evaluating high and medium voltage circuit breakers in both substation and industrial environments. It supports a comprehensive range of functions and includes all essential measurements recommended by the IEEE C37 and IEC 62271 standards, making it a highly adaptable instrument for various applications.
Megger EGIL200 Key Features
- Mid-range circuit breaker analyser providing a new level of accuracy to your standard measurements
- Intuitive operation offers final measurement results with a minimum of user interaction
- Measurement performance inherited from market leader Megger TM series circuit breaker analysers
- Instrument and accessories designed for the most demanding field conditions
- Easy-to-use and intuitive interface
Megger EGIL200 Specifications
| Category | Specification |
|---|---|
| General Specifications | |
| Warm-up time | Valid after 30 minutes |
| System time base drift | 0.001% per year |
| Environment | Medium and high voltage substations and industrial environments |
| Temperature | |
| Operating | -20 °C to +55 °C (-4 °F to +131 °F) |
| Storage & transport | -30 °C to +70 °C (-22 °F to +158 °F) |
| Humidity | 5% – 95% RH, non-condensing |
| Altitude | Up to 2000 m; 2000 m to 5000 m with specific voltage restrictions |
| Compliance | LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EU |
| Power and Physical Specifications | |
| Mains input | 100 – 240 V AC, 50/60 Hz, 110 – 250 V DC |
| Power consumption | 200 VA (max.) |
| Dimensions | 474 x 415 x 214 mm (18.7 x 16.3 x 8.4 inches) |
| Weight | 12 kg (26.5 lbs) |
| IP-rating | IP67 (closed case), IP20 (open case) |
| Data memory capacity | 1.4 GB (up to 6000 basic or 1500 advanced recordings) |
| Display and Interfaces | |
| Display | 7″ (17.8 cm) LCD, Capacitive touch screen |
| Languages | English, French, German, Spanish, Swedish |
| Interfaces | 3 USB A, 1 USB B, RJ45 |
| Output Specifications | |
| External outputs | Trig output for SDRM20X |
| Output voltage | 12 V DC ±10% |
| Short circuit protection | PTC 250 mA |
| Switching current | <250 mA, resistive load |
| Control Section | |
| Control pulse outputs | Close, open 1 and open 2 |
| Time base inaccuracy | ±0.01% of reading ±1 sample interval |
| Max. sample rate | 40 kHz |
| Measurement time | Up to 10 s |
| Measurement Specifications | |
| Current measurement range | ±80 A |
| Voltage measurement range | Max. ±400 V |
| Timing M/R section | 3, 6, or 12 channels selectable at ordering |
| Analog section | 1 or 3 isolated channels |
| Digital section | 3 channels |
| Timing Aux section | 3 isolated channels |
| Optional Features | |
| Printer | Thermal, paper width 112 mm or 114 mm |
| Operating temperature (printer) | 0 °C to +60 °C |
| Storage & transport (printer) | -20 °C to +70 °C |
For more details please check the Datasheet.
Specifications
| Category | Specification |
|---|---|
| General Specifications | |
| Warm-up time | Valid after 30 minutes |
| System time base drift | 0.001% per year |
| Environment | Medium and high voltage substations and industrial environments |
| Temperature | |
| Operating | -20 °C to +55 °C (-4 °F to +131 °F) |
| Storage & transport | -30 °C to +70 °C (-22 °F to +158 °F) |
| Humidity | 5% – 95% RH, non-condensing |
| Altitude | Up to 2000 m; 2000 m to 5000 m with specific voltage restrictions |
| Compliance | LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EU |
| Power and Physical Specifications | |
| Mains input | 100 – 240 V AC, 50/60 Hz, 110 – 250 V DC |
| Power consumption | 200 VA (max.) |
| Dimensions | 474 x 415 x 214 mm (18.7 x 16.3 x 8.4 inches) |
| Weight | 12 kg (26.5 lbs) |
| IP-rating | IP67 (closed case), IP20 (open case) |
| Data memory capacity | 1.4 GB (up to 6000 basic or 1500 advanced recordings) |
| Display and Interfaces | |
| Display | 7″ (17.8 cm) LCD, Capacitive touch screen |
| Languages | English, French, German, Spanish, Swedish |
| Interfaces | 3 USB A, 1 USB B, RJ45 |
| Output Specifications | |
| External outputs | Trig output for SDRM20X |
| Output voltage | 12 V DC ±10% |
| Short circuit protection | PTC 250 mA |
| Switching current | <250 mA, resistive load |
| Control Section | |
| Control pulse outputs | Close, open 1 and open 2 |
| Time base inaccuracy | ±0.01% of reading ±1 sample interval |
| Max. sample rate | 40 kHz |
| Measurement time | Up to 10 s |
| Measurement Specifications | |
| Current measurement range | ±80 A |
| Voltage measurement range | Max. ±400 V |
| Timing M/R section | 3, 6, or 12 channels selectable at ordering |
| Analog section | 1 or 3 isolated channels |
| Digital section | 3 channels |
| Timing Aux section | 3 isolated channels |
| Optional Features | |
| Printer | Thermal, paper width 112 mm or 114 mm |
| Operating temperature (printer) | 0 °C to +60 °C |
| Storage & transport (printer) | -20 °C to +70 °C |
For more details please check the Datasheet.