Megger EGIL200 Circuit Breaker Analyser
Short Description:
Looking to buy a Megger EGIL200? Discover great prices and deals in Dubai, UAE. Elevate your work with this cutting-edge tool today!
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
14
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Megger EGIL200 Circuit Breaker Analyser
The Megger EGIL200 circuit breaker analyser was designed to meet the market demand for a reasonably priced, mid-range analyser that is quick and straightforward to operate. The focus during its development was on simplicity, significantly reducing the time needed to set up for measurements. It features a quick test mode where all necessary settings are readily accessible on a single screen, making it easy to start tests immediately.
This tool is particularly effective for evaluating high and medium voltage circuit breakers in both substation and industrial environments. It supports a comprehensive range of functions and includes all essential measurements recommended by the IEEE C37 and IEC 62271 standards, making it a highly adaptable instrument for various applications.
Megger EGIL200 Key Features
- Mid-range circuit breaker analyser providing a new level of accuracy to your standard measurements
- Intuitive operation offers final measurement results with a minimum of user interaction
- Measurement performance inherited from market leader Megger TM series circuit breaker analysers
- Instrument and accessories designed for the most demanding field conditions
- Easy-to-use and intuitive interface
Megger EGIL200 Specifications
Category | Specification |
---|---|
General Specifications | |
Warm-up time | Valid after 30 minutes |
System time base drift | 0.001% per year |
Environment | Medium and high voltage substations and industrial environments |
Temperature | |
Operating | -20 °C to +55 °C (-4 °F to +131 °F) |
Storage & transport | -30 °C to +70 °C (-22 °F to +158 °F) |
Humidity | 5% – 95% RH, non-condensing |
Altitude | Up to 2000 m; 2000 m to 5000 m with specific voltage restrictions |
Compliance | LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EU |
Power and Physical Specifications | |
Mains input | 100 – 240 V AC, 50/60 Hz, 110 – 250 V DC |
Power consumption | 200 VA (max.) |
Dimensions | 474 x 415 x 214 mm (18.7 x 16.3 x 8.4 inches) |
Weight | 12 kg (26.5 lbs) |
IP-rating | IP67 (closed case), IP20 (open case) |
Data memory capacity | 1.4 GB (up to 6000 basic or 1500 advanced recordings) |
Display and Interfaces | |
Display | 7″ (17.8 cm) LCD, Capacitive touch screen |
Languages | English, French, German, Spanish, Swedish |
Interfaces | 3 USB A, 1 USB B, RJ45 |
Output Specifications | |
External outputs | Trig output for SDRM20X |
Output voltage | 12 V DC ±10% |
Short circuit protection | PTC 250 mA |
Switching current | <250 mA, resistive load |
Control Section | |
Control pulse outputs | Close, open 1 and open 2 |
Time base inaccuracy | ±0.01% of reading ±1 sample interval |
Max. sample rate | 40 kHz |
Measurement time | Up to 10 s |
Measurement Specifications | |
Current measurement range | ±80 A |
Voltage measurement range | Max. ±400 V |
Timing M/R section | 3, 6, or 12 channels selectable at ordering |
Analog section | 1 or 3 isolated channels |
Digital section | 3 channels |
Timing Aux section | 3 isolated channels |
Optional Features | |
Printer | Thermal, paper width 112 mm or 114 mm |
Operating temperature (printer) | 0 °C to +60 °C |
Storage & transport (printer) | -20 °C to +70 °C |
For more details please check the Datasheet.
Specifications
Category | Specification |
---|---|
General Specifications | |
Warm-up time | Valid after 30 minutes |
System time base drift | 0.001% per year |
Environment | Medium and high voltage substations and industrial environments |
Temperature | |
Operating | -20 °C to +55 °C (-4 °F to +131 °F) |
Storage & transport | -30 °C to +70 °C (-22 °F to +158 °F) |
Humidity | 5% – 95% RH, non-condensing |
Altitude | Up to 2000 m; 2000 m to 5000 m with specific voltage restrictions |
Compliance | LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EU |
Power and Physical Specifications | |
Mains input | 100 – 240 V AC, 50/60 Hz, 110 – 250 V DC |
Power consumption | 200 VA (max.) |
Dimensions | 474 x 415 x 214 mm (18.7 x 16.3 x 8.4 inches) |
Weight | 12 kg (26.5 lbs) |
IP-rating | IP67 (closed case), IP20 (open case) |
Data memory capacity | 1.4 GB (up to 6000 basic or 1500 advanced recordings) |
Display and Interfaces | |
Display | 7″ (17.8 cm) LCD, Capacitive touch screen |
Languages | English, French, German, Spanish, Swedish |
Interfaces | 3 USB A, 1 USB B, RJ45 |
Output Specifications | |
External outputs | Trig output for SDRM20X |
Output voltage | 12 V DC ±10% |
Short circuit protection | PTC 250 mA |
Switching current | <250 mA, resistive load |
Control Section | |
Control pulse outputs | Close, open 1 and open 2 |
Time base inaccuracy | ±0.01% of reading ±1 sample interval |
Max. sample rate | 40 kHz |
Measurement time | Up to 10 s |
Measurement Specifications | |
Current measurement range | ±80 A |
Voltage measurement range | Max. ±400 V |
Timing M/R section | 3, 6, or 12 channels selectable at ordering |
Analog section | 1 or 3 isolated channels |
Digital section | 3 channels |
Timing Aux section | 3 isolated channels |
Optional Features | |
Printer | Thermal, paper width 112 mm or 114 mm |
Operating temperature (printer) | 0 °C to +60 °C |
Storage & transport (printer) | -20 °C to +70 °C |
For more details please check the Datasheet.