Megger Cb-845 Circuit Breaker Test Set

Short Description:

MEGGER CB845 Key Features :

  • Digital memory ammeter
  • Digital, multirange timer
  • Lightweight and portable
  • High-current output
  • Solid-state output initiates circuitry

Product purchase

SKU: 5098 Category:
Brand:Megger

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

11 People watching this product now!

Terms of sending goods ›

  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

The lightweight, two-section design of Model Megger CB845 enables the user to easily transport the unit into areas previously inaccessible to high-current test equipment such as elevated or subsurface load centers, shipboard power panels, elevator machinery rooms, and other isolated locations.

MEGGER CB-845 Specifications:

  • Input Voltage (switch-selected):208 and 240 V, 1f, 30 A
  • Input Frequency (specify one):50 Hz O R 60 Hz
  • Digital Display:31⁄2 digit, extra-bright LED display with 0.3 in. (7.62 mm) numerals
  • Ranges (switch-selected):0 to 19.99/199.9/1999 A/10 kA
  • Continuous Accuracy (overall ammeter system):±1% of reading, ±1 digit on three high ranges, ±1 digit on low range
  • Control Units:11.25 H x 21.75 W x 17.5 D in. (29 H x 55 W x 44 D cm)
  • Output Unit:11.25 H x 21.75 W x 19.5 D in. (29 H x 55 W x 49 D cm)
  • Control Unit:69.25 lb (31.4 kg)
  • Output Unit:(50 Hz): 123 lb (55.8 kg)
  • Output Unit:(60 Hz): 103 lb (46.8 kg)

DATA sheet

Data Sheet

Specifications

Category Specification Details
Input Input Voltage (switch-selected) 208 and 240 V, 1f, 30 A
Input Frequency (specify one) 50 Hz OR 60 Hz
Output Output Range The output is continuously adjustable to accommodate a variety of test circuit impedances: 0 to 1200 A at 6 V max.
Output Capacity The output circuit is designed to provide short-duration overloads. Capable of testing time-delay characteristics of devices rated up to 500 A using a test current of three times their rating (1500 A). For instantaneous trip tests, provides 5000 A through a typical 500 A molded-case circuit breaker.
Overload Capability Designed so that current ratings may be exceeded for short durations. Output current determined by load circuit impedance and voltage rating.
Output Initiate Initiate Circuit The test set uses a solid-state output initiating circuit using a triac to increase reliability and eliminate contact maintenance.
Control Circuit Provides momentary and maintained modes to control output duration. Used for short durations or maintained until manually turned off or the device under test operates.
Timer Description A solid-state digital timer measures elapsed time in seconds or cycles, using a crystal controlled oscillator for accuracy independent of line frequency.
Display Type 5-digit, extra-bright LED display with 0.3 in. (7.62 mm) numerals
Accuracy and Ranges Ranges (switch-selected) 0 to 99.999 s, 0 to 999.99 s, 0 to 99999 cycles
Accuracy ±0.005% of reading, ±1 digit