Fluke 376 FC Clamp Meter
Short Description:
FLUKE 376 FC Key features :
- Measures AC/DC current with included iFlex current probe
- VFD low pass filter for accurate measurements of non-linear signals
- Remotely log, trend, and monitor to pinpoint intermittent faults
- Inrush measurement to filter out the noise and capture the starting current
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
18
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
The Fluke 376 FC True-RMS Clamp Meter with iFlex is industrial and commercial electricians’ most advanced troubleshooting tool. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend, and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.
fluke 376 review
The 376 FC clamp meter uses an integrated low-pass filter to accurately measure non-linear signals, such as adjustable speed drives, electronic ballasts, and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out the noise and capture the motor starting current exactly as the circuit protection sees it.
Fluke 376 FC True-rms Clamp Meter
fluke-376 fc/wwg
- Measure:
- Voltage to 1000 V AC or DC
- Resistance to 60 kΩ with continuity detection
- Min, max, average, and inrush recording to capture variations automatically
- 500 mV DC measurement range to interface with other accessories
- 1000 μF capacitance measurement
Fluke 376 fc true rms clamp meter with iflex
The new Fluke 376 Clamp Meter offers improved performance that’s perfect for a variety of today’s measurement situations. With true RMS AC current and voltage measurements, the Fluke 376 can measure up to 1000V and 1000A in both AC and DC modes. In addition, the Fluke 376 includes the new iFlex flexible current probe, which extends the measurement range to 2500 A AC while providing greater viewing flexibility, the ability to measure around awkward conductors and better cable access. The Fluke 376 is a direct replacement for the Fluke 337 Clamp Meter.
Fluke 376 fc true-rms clamp meter with iflex
Fluke 376 True-RMS AC/DC Clamp Meter with iFlex® Extend your measurement range with greater flexibility. The Fluke 376 true-rms clamp meter with iFlex® lets you test around odd-sized conductors and extend the measurement range to 2500 A AC.
other products
You can check our other products like Fluke 369 FC True-RMS AC Clamp Meter, and Fluke 375 FC True-RMS AC/DC Clamp Meter and buy clamp meter fluke on our website.
fluke 376 fc specification :
- AC Current Range (Jaw): 999.9 A
- AC Current( Flexible Current Probe )Range : 2500 A
- DC Current Range: 999.9 A
- AC Voltage Range: 1000 V
- DC Voltage Range: 1000 V
- mV dc Range : 500.0 mV
- Amps Frequency ( Jaw ) Range: 5.0 Hz to 500.0 Hz
- Amps Frequency(Flexible Current Probe) Range:5.0 Hz to 500.0 Hz
- Resistance Range: 60.00 kΩ
- Capacitance Range: 1000 μF
- Size (L x W x H) : 249 mm x 85 mm x 45 mm
- Weight (with Batteries): 395 g
- Operating Temperature: -10 °C to 50 °C
- Storage Temperature: -40 °C to 60 °C
fluke 376 fc accessories
- Fluke C33 Soft Carrying Case
- Fluke CAMO-37 Camouflage Carrying Case
- Fluke C150 Soft Carrying Case
- Fluke AC220 SureGripâ„¢ Alligator Clips
- Fluke AC87 Heavy Duty Bus Bar Clip Set
- Fluke AC89 Heavy Duty Insulation Piercing Test Clip
- Fluke TL75 Hard Pointâ„¢ Test Lead Set
- Fluke TP1 Slim Reach Test Probes
- Fluke TL175 TwistGuardâ„¢ Test Leads
- Fluke LVD1A Non-Contact Voltage Tester with LED Flashlight
- Fluke L206 Deluxe LED Hat Light
- Fluke 376 fc calibration manual
- Fluke 376 fc manual
specification
AC Current via Jaw | 374 and 375 | 376 |
---|---|---|
Range | 600.0 A | 999.9 A |
Resolution | 0.1 A | |
Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
|
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
AC Current via Flexible Current Probe | 374 and 375 | 376 |
---|---|---|
Range | 2500 A | |
Resolution | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
Accuracy | 3% ±5 digits (5 – 500 Hz) | |
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
DC Current | 374 and 375 | 376 |
---|---|---|
Range | 600.0 A | 999.9 A |
Resolution | 0.1 A | |
Accuracy | 2% ± 5 digits |
AC Voltage | 374 and 375 | 376 | |
---|---|---|---|
Range | 600.0 V | 1000 V | |
Resolution | 0.1 V | 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
|
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) |
DC Voltage | 374 and 375 | 376 | |
---|---|---|---|
Range | 600.0 V | 1000 V | |
Resolution | 0.1 V | 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
|
Accuracy | 1% ± 5 digits |
mV dc | 375 and 376 |
---|---|
Range | 500.0 mV |
Resolution | 0.1 mV |
Accuracy | 1% ± 5 digits |
Frequency via Jaw | 375 and 376 |
---|---|
Range | 5.0 – 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5% ± 5 digits |
Trigger Level | 5 – 10 Hz, ≥10 A 10 – 100 Hz, ≥5 A 100 – 500 Hz, ≥10 A |
Frequency via Flexible Current Probe | 375 and 376 |
---|---|
Range | 5.0 – 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5% ± 5 digits |
Trigger Level | 5 – 20 Hz, ≥ 25 A 20 – 100 Hz, ≥ 20 A 100 – 500 Hz, ≥ 25 A |
Resistance | 374 | 375 and 376 |
---|---|---|
Range | 6000 Ω | 60 kΩ |
Resolution | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
Accuracy | 1% ± 5 digits |
Capacitance | 1000 μF | |
---|---|---|
Resolution | 0.1 μF (≤ 100 μF) 1 μF (≤ 1000 μF) |
|
Accuracy | 1% ± 4 digits |
Mechanical Specifications
Size (L x W x H) | 246 mm x 83 mm x 43 mm |
---|---|
Weight | 388 g |
Jaw Opening | 34 mm |
Flexible Current Probe Diameter | 7.5 mm |
Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m |
Environmental Specifications
Operating Temperature | 10°C – +50°C |
---|---|
Storage Temperature | -40°C – +60°C |
Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
Operating Altitude | 3000 meters |
Storage Altitude | 12,000 meters |
EMC | EN 61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
Safety Specifications
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
---|
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Fluke 376 FC Clamp Meter
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
Fluke 323 True RMS Clamp Meter
Rated 5.00 out of 5
In stock
Kyoritsu 2031 Miniature AC Clamp Meter
Rated 0 out of 5
In stock
Anthony –