Fluke 393 FC True-rms Clamp Meter with iFlex
Short Description:
FLUKE 393 FC 1500 V Clamp Meter Key features :
- Measure safely with CAT III 1500 V rated clamp meter
- Thin jaw for access to cables in crowded combiner boxes
- Sturdy IP54 rated for outdoor use
- Work efficiently with dc power measurement, audio polarity and visual continuity
Call for Best Price 00971(04) 447 6031 00971(04) 344 9868
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
The fluke 393 FC CAT III 1500V True-RMS Clamp Meter with iFlex is designed for technicians working in high-voltage DC environments: solar panels, wind power, electric railways, and data center battery banks for uninterruptible power systems. Measure up to 1500V DC, 1000V AC, and up to 999.9A DC or AC through the jaw.
The included iFlex flexible current probe extends AC current measurements up to 2500 amps. This clamp has a narrow jaw that allows you to access wires in crowded junction boxes. The test leads have been specially developed for your task and are also designed for CAT III 1500 VDC.
Fluke 393 FC functions:
- IP54-rated, ideal for work outdoors on solar arrays and wind power systems
- DC power measurement, showing readings in kVA
- Audio Polarity indicator helps prevent accidental misfires
- Visual Continuity turns to provide a bright green light in the display, ideal when working in dark and noisy environments.
- Logging and reporting of test results via Fluke Connect software
- When measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable in tight spaces.
- The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.
Specifications
Specifications | |
---|---|
General | |
Maximum voltage between any Terminal and Earth Ground | AC: 1000 V DC: 1500 V |
Batteries | 2 AA IEC LR6 alkaline |
Display | Dual display with backlight |
Automatic Power Off | 20 minutes |
Electrical | |
Accuracy | |
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]). | |
Temperature Coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C |
AC Current: Jaw | |
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % + 5 digits (10 Hz to 100 Hz) 2.5 % + 5 digits (100 Hz to 500 Hz) |
Crest Factor (50/60 Hz) | 2.5 @600.0 A 3.0 @500.0 A 1.42 @999.9 A Add 2 % for C.F. >2 |
AC Current: Flexible Current Probe | |
Range | 999.9 A 2500 A |
Resolution | 0.1 A (≤999.9 A) 1 A (≤2500 A) |
Accuracy | 3 % RD + 5 digits (10 Hz to 500 Hz) |
Crest Factor (50/60Hz) | 2.5 @1400 A 3.0 @1100 A 1.42 @2500 A Add 2 % for C.F. >2 |
Distance from Optimum | i2500-10 Flex: 0.5 in (12.7 mm) ±0.5 % i2500-18 Flex: 1.4 in (35.6 mm) ±0.5 % A: 0.5 in (12.7 mm), 1.4 in (35.6 mm) ±0.5 % B: 0.8 in (20.3 mm), 2.0 in (50.8 mm) ±1.0 % C: 1.4 in (35.6 mm), 2.5 in (63.5 mm) ±2.0 % |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | |
DC Current | |
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % RD + 5 digits[1] [1] When using the ZERO (B) function to compensate for offsets. |
AC Voltage | |
Range | 600.0 V 1000 V |
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
Accuracy | 1 % RD + 5 digits (20 Hz to 500 Hz) |
DC Voltage | |
Range | 600.0 V 1500 V |
Resolution | 0.1 V (≤600.0 V) 1 V (≤1500 V) |
Accuracy | 1 % RD + 5 digits |
mV DC | |
Range | 500.0 mV |
Resolution | 0.1 mV |
Accuracy | 1 % RD + 5 digits |
Amps Frequency: Jaw | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A |
Amps Frequency: Flexible Current Probe | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A |
Voltage Frequency | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 20 Hz, ≥5 V 20 Hz to 100 Hz, ≥5 V 100 Hz to 500 Hz, ≥10 V |
DC Power | |
Range | 600.0 kVA (600.0 V DC range) 1500 kVA (1500 V DC range) |
Resolution | 0.1 kVA 1 kVA |
Accuracy | 2 % RD + 2.0 kVA 2 % RD + 20 kVA |
Resistance | |
Range | 600.0 Ω 6000 Ω 60.00 kΩ |
Resolution | 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 0.01 kΩ (≤60.00 kΩ) |
Accuracy | 1 % RD + 5 digits |
Capacitance | |
Range | 100.0 μF 1000 μF |
Resolution | 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) |
Accuracy | 1 % RD + 5 digits |
Inrush Trigger Level | 5 A |
Mechanical | |
Size (L x W x H) | 281 mm x 84 mm x 49 mm |
Weight (with batteries) | 520 g |
Jaw Opening | 34 mm |
Flexible Current Probe Diameter | 7.5 mm |
Flexible Current Probe Cable Length | (head to electronics connector) 1.8 m |
Environmental | |
Operating Temperature | -10 °C to 50 °C |
Storage Temperature | -40 °C to 60 °C |
Operating Humidity | Non condensing (<10°C) ≤90 % RH (at 10 °C to 30 °C) ≤75 % RH (at 30 °C to 40 °C) ≤45 % RH (at 40 °C to 50 °C) |
Operating Altitude | 2000 m |
Storage Altitude | 12,000 m |
Ingress Protection (IP) Rating | IEC 60529: IP54 non-operating |
Datasheet
Fluke 393 FC True-rms Clamp Meter with iFlex User Manual
The Fluke 393 FC True-rms Clamp Meter with iFlex user manual offers comprehensive guidance on operating the clamp meter, using the iFlex probe, and connecting via Fluke Connect®. This manual ensures technicians can safely and efficiently measure high-voltage DC and AC current in demanding environments.