Megger MIT330 Insulation and Continuity Testers
Short Description:
Get the best deal on Megger MIT330 in Dubai, UAE. Shop now for reliable water analysis equipment at affordable prices!
Megger MIT330 Insulation and Continuity Testers
The Megger MIT330 Insulation and Continuity Tester is an advanced and reliable instrument designed to meet the needs of professionals in the electrical testing field. This tester provides a comprehensive range of features for insulation resistance and continuity testing, ensuring accurate and dependable results.
All instruments in the MIT300 range indicate insulation resistance up to 999 MΩ, offer 200 mA continuity testing, feature a fast-reacting continuity buzzer, and provide facilities for nulling test lead resistance. The entry-level MIT300 provides insulation test voltages of 250 V and 500 V, whereas the other models in the range support testing at 250 V, 500 V, and 1000 V. for more electrical insulation tester megger visit the link.
Megger MIT330 Key Features
- Extremely easy to use
- Tough rubber armoured case
- Self contained protective cover
- Live circuit warning
- Weatherproof to IP54
- Intelligent safety system for protection
Megger MIT330 Specifications
Feature | Details |
---|---|
Product Name | Megger MIT330 Insulation and Continuity Tester |
Insulation Test Voltages | 250V, 500V, 1000V |
Insulation Resistance Range | Up to 999 MΩ |
Continuity Test Range | 0.01 Ω to 100 Ω |
Test Current | >200 mA (for continuity testing) |
Accuracy (at 20° C) | ±3% ± 2 digits for insulation resistance |
Resistance Range | Can be used for diode testing |
Measuring Range | 10 Ω – 1 MΩ |
Open Circuit Voltage | 5 V |
Short Circuit Current | 1.5 mA |
Accuracy (at 20° C) | ±5% ±2 digits up to 100 kΩ |
Voltage Range | 0 – 600 V AC (50/60 Hz) or DC |
Voltage Accuracy (at 20 °C) | ±1%, ±2 digits (MIT310, 320, 330 DC or AC 50/60 Hz) |
Temperature Coefficient | <0.1% per °C on all ranges |
Default Voltmeter | Operates as a voltmeter if >25 V AC or DC is applied |
Test Inhibit | Testing is inhibited if more than 50 volts is detected |
Auto Power Down | Operates after 10 minutes if left in standby mode |
Operating Temperature Range | -10 °C to +60 °C |
Operating Humidity | 93% R.H. at +40 °C max |
Storage Temperature Range | -25 °C to +70 °C |
Test Result Storage | 1000 results |
Job Number Locations | 255 locations |
Distribution Board Locations | 99 locations |
Circuits | 99 locations |
Phases | P1, P2, P3 |
Last Recorded Result | May be recalled to the display |
Data Download | All data can be downloaded to a PC using Download Manager (available at megger.com) and uploaded into Megger Certsuite (Certsuite.app) |
Communications | USB interface |
Environmental Protection | IP54 |
Fuses | Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum. Display shows if fuse is ruptured |
Safety | Meets the requirements of IEC61010-1 Cat III 600 V phase to earth |
Automatic Discharge | After an insulation test, the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored |
Power Supply | 8 x 1.5 V cells IEC LR6 type (AA alkaline). Rechargeable NiCd or NiMH cells may be used |
Battery Condition | Constantly shown on the display as a four-section bargraph |
Battery Life | 5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries |
Weight | 980 g |
Dimensions | 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches) |
Specifications
Feature | Details |
---|---|
Product Name | Megger MIT330 Insulation and Continuity Tester |
Insulation Test Voltages | 250V, 500V, 1000V |
Insulation Resistance Range | Up to 999 MΩ |
Continuity Test Range | 0.01 Ω to 100 Ω |
Test Current | >200 mA (for continuity testing) |
Accuracy (at 20° C) | ±3% ± 2 digits for insulation resistance |
Resistance Range | Can be used for diode testing |
Measuring Range | 10 Ω – 1 MΩ |
Open Circuit Voltage | 5 V |
Short Circuit Current | 1.5 mA |
Accuracy (at 20° C) | ±5% ±2 digits up to 100 kΩ |
Voltage Range | 0 – 600 V AC (50/60 Hz) or DC |
Voltage Accuracy (at 20 °C) | ±1%, ±2 digits (MIT310, 320, 330 DC or AC 50/60 Hz) |
Temperature Coefficient | <0.1% per °C on all ranges |
Default Voltmeter | Operates as a voltmeter if >25 V AC or DC is applied |
Test Inhibit | Testing is inhibited if more than 50 volts is detected |
Auto Power Down | Operates after 10 minutes if left in standby mode |
Operating Temperature Range | -10 °C to +60 °C |
Operating Humidity | 93% R.H. at +40 °C max |
Storage Temperature Range | -25 °C to +70 °C |
Test Result Storage | 1000 results |
Job Number Locations | 255 locations |
Distribution Board Locations | 99 locations |
Circuits | 99 locations |
Phases | P1, P2, P3 |
Last Recorded Result | May be recalled to the display |
Data Download | All data can be downloaded to a PC using Download Manager (available at megger.com) and uploaded into Megger Certsuite (Certsuite.app) |
Communications | USB interface |
Environmental Protection | IP54 |
Fuses | Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum. Display shows if fuse is ruptured |
Safety | Meets the requirements of IEC61010-1 Cat III 600 V phase to earth |
Automatic Discharge | After an insulation test, the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored |
Power Supply | 8 x 1.5 V cells IEC LR6 type (AA alkaline). Rechargeable NiCd or NiMH cells may be used |
Battery Condition | Constantly shown on the display as a four-section bargraph |
Battery Life | 5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries |
Weight | 980 g |
Dimensions | 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches) |