Megger OCR15D Oil Circuit Recloser Test Set
Short Description:
The Megger ocr15d and ocr50d oil circuit recloser test sets are self-contained mobile test sets specifically designed to verify the proper operation of automatic circuit reclosers under simulated overload and fault conditions.
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
13
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Megger OCR15D
The Megger OCR15D Automatic Oil Circuit Recloser Test Set is a self-contained, mobile unit designed to ensure the accurate functioning of automatic circuit reclosers by simulating overload and fault conditions. This verification is crucial for maintaining reliable system operation, protection, and coordination.
Equipped with a digital control and instrumentation system, the OCR15D offers straightforward operation and delivers precise test results. It features a variable high-current output and an impedance compensation network, which work together to stabilize the output current during testing.
The Automatic Oil Circuit Recloser Test Sets are capable of testing reclosers that utilize either oil or vacuum interrupters. Moreover, they can conduct primary injection (high-current) testing on electronically controlled reclosers. The following are typical tests that can be performed on reclosers using these test sets.
Megger OCR15D Key Features
- Preprogrammed test sequences for reclosers
- Impedance compensation to properly test reclosers with variable impedance characteristics
- Accurate duplication of test results
- Simple operation and precise test results
- Full color, high resolution, TFT LCD touch screen
- OCR software runs under PowerDB software suite
- View, save and export test reports for printing or importing into PowerDB
- Digitized TCC Curves included in the OCR software
- Simplified Control Software – easy to learn and use
Specifications
Input Specifications | ||
---|---|---|
Model No. | Input Voltage (Single-Phase) | Input Frequency |
OCR15D-208/60 | 208 V ±5% at 150 A, 230 V ±5% at 150 A, 460 V ±5% at 40 A, 575 V ±5% at 35 A | 50/60 Hz |
OCR15D-220/50 | 220 V ±5% at 150 A, 240 V ±5% at 150 A, 380 V ±5% at 40 A, 415 V ±5% at 35 A | 50/60 Hz |
OCR50D-460 | 460 V ±5% at 150 A | 50/60 Hz |
OCR50D-400 | 400 V ±5% at 150 A | 50/60 Hz |
Output Specifications | ||
Model | Output Rating | Rated Output Ranges |
OCR15D | 15 kVA | 0 to 2000 A at 7.5 V max, 0 to 1500 A at 10 V max, 0 to 1000 A at 15 V max, 0 to 500 A at 30 V max, 0 to 250 A at 60 V max, 0 to 100 A at 150 V max, 0 to 50 A at 300 V max, 0 to 25 A at 600 V max |
OCR50D | 50 kVA | 0 to 2800 A at 18 V max, 0 to 2000 A at 25 V max, 0 to 1400 A at 36 V max, 0 to 1000 A at 50 V max, 0 to 700 A at 71.5 V max, 0 to 500 A at 100 V max, 0 to 350 A at 143 V max, 0 to 250 A at 200 V max, 0 to 150 A at 334 V max, 0 to 100 A at 500 V max, 0 to 50 A at 1000 V max |
Rated 0 out of 5