Megger PS9130 AND PS9160 Universal Circuit Breaker Test
Model MEGGER PS9130 AND PS9160 UNIVERSAL CIRCUIT BREAKER TEST SETS are specifically designed to test low-voltage power circuit breakers and molded-case circuit breakers that are equipped with thermal-magnetic or solid-state trip devices by simulating an overload or fault condition.
MME Shopping Event
Hurry and get discounts on Most of MME Products up to 20%
Call for Price
Megger PS9130 AND PS9160 Universal Circuit Breaker Test Sets
Model PS-9130 and Model PS-9160 Series Universal Circuit Breaker Test Sets are specifically designed to test low-voltage power circuit breakers and molded-case circuit breakers that are equipped with thermal-magnetic or solid-state trip devices by simulating an overload or fault condition.
Model PS-9130 and Model PS-9160 are controlled by the Model PLC-2000 Prime Logic Controls. This microprocessor monitors the output, stores the test data, and performs the automatic test functions. After the test information is stored, Model PLC-2000 can print the test data using a built-in RS-232 printer port.
Key Features of PS-9130 and PS-9160
- Both the PS-9130 and PS-9160 are universal in their application, capable of testing virtually all types of low voltage circuit breakers. This versatility extends to other high current applications as well, such as performing ratio tests on current transformers and primary injection testing on high voltage breakers and their protective relays.
- The PS-9130 is designed for testing circuit breakers rated up to 3000 amperes, making it suitable for a majority of residential and commercial applications. The PS-9160, on the other hand, extends its capabilities to handle circuit breakers rated up to 6000 amperes, ideal for larger installations and industrial applications.
- Both models are controlled by the Model PLC-2000 Prime Logic Controls. This advanced microprocessor not only monitors the output during tests but also stores test data and automates test functions. This integration simplifies the testing process and ensures accuracy and repeatability in results.
Megger PS9130 AND PS9160 Specifications
- Instrumentation—Model PLC-2000
- Digital Memory Ammeter
- Display: Vacuum-fluorescent,31/2digit display
- Ranges:200/2000/20,000/200,000 A
- Accuracy:±1% full scale, ± LSD after two cycles ، ±2% full scale on 200-A range
- Digital Timer
- Display: Vacuum-fluorescent 4-digit displaY
- Ranges:0.001 to 9999 s, 0.1 to 9999 cycles
- Accuracy
- Seconds Mode:±0.0133 seconds, ±0.005% reading, ± LSD
- Cycles Mode:±0.1% reading, ± LSD
- Protection:
- Fuse, circuit breaker, and overload protection devices are incorporated. The output-initiating SCRs are forced-air cooled and temperature sensors provide protection from overheating. Emergency-stop pushbutton is provided to de-energize all input power to the test set
- Enclosure
- For safety and mobility, the test set is housed in a rugged sheet-metal enclosure with a low center of gravity, tow ring, lifting eyes, and large locking swivel casters with brakes. To increase maneuverability, all four casters swivel. They can also be locked easily into a fixed position when desired. The test set’s-compact size permits easy movement through narrow doors.
1 review for Megger PS9130 AND PS9160 Universal Circuit Breaker Test
Clear filtersYou must be logged in to post a review.
Brand
Megger
Megger
Megger since 1889 is a leading global premium manufacturer of measurement and testing technology. Megger top priority has always been to make your everyday work easier and safer. As such, insulation testers, micro-ohmmeters, and multimeters are among the long line of Megger inventions, making this brand one of the pioneers in the electrical industry. Megger products combine many years of experience and the valued feedback from our global users with the inventiveness and conscientiousness of our product developers. In Germany, we manufacture at three sites, Aachen, and Baunach near Bamberg and Radeburg near Dresden. Other manufacturing locations are based in Sweden, England, and America.
Specifications
Component | Specification | Details |
---|---|---|
Digital Memory Ammeter | Display | Vacuum-fluorescent, 3½ digit display |
Ranges | 200/2000/20,000/200,000 A | |
Accuracy | ±1% full scale, ± LSD after two cycles, ±2% full scale on 200-A range | |
Digital Timer | Display | Vacuum-fluorescent 4-digit display |
Ranges | 0.001 to 9999 s, 0.1 to 9999 cycles | |
Accuracy – Seconds Mode | ±0.0133 seconds, ±0.005% reading, ± LSD | |
Accuracy – Cycles Mode | ±0.1% reading, ± LSD |
Specifications
Related Products
Fluke 279 FC True-rms Thermal Multimeter
In stock
FLUKE 369 FC Leakage Current Clamp Meter
In stock
Fluke 289 TRMS Epic Logging Multimeter with TrendCapture
In stock
FLUKE 393 FC : an epic True-rms Clamp Meter with iFlex
In stock
FLUKE 287 True-RMS Electronics Logging Multimeter
In stock
FLUKE 83V Average Responding Industrial Multimeter
In stock
FLUKE 902 FC True-RMS HVAC Clamp Meter
In stock
FLUKE 117 An Excellent Electricians Multimeter
In stock
stephen –
very good product