Megger PAT150R-UK Portable Appliance Tester

(No Reviews)

The Megger PAT150R-UK is a reliable and portable appliance tester designed for electricians and safety compliance professionals. It provides fast, accurate testing of electrical appliances, including earth continuity, insulation resistance, polarity, and leakage current. Compact, rugged, and easy to use, this tester ensures compliance with UK safety standards while streamlining on-site inspections and routine maintenance.

Terms of sending goods ›
  • In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
  • For out-of-stock items, delivery may take 2 to 4 business weeks.
SKU: 125153 Category:
Brand:Megger

AED 5,060 (excl.VAT)

Order in WhatsApp
In stockDelivers in 2-3 business days.
Description

Megger PAT150R-UK Portable Appliance Tester

The Megger PAT150R-UK is a professional-grade Portable Appliance Tester designed for electricians, service engineers, and safety compliance professionals who need accurate, reliable, and efficient appliance testing. It provides a full range of essential safety tests to ensure electrical appliances comply with UK regulations and safety standards.

Built with ease of use and portability in mind, the PAT150R-UK performs critical tests such as earth continuity, insulation resistance, polarity, and leakage current, allowing technicians to quickly assess the safety of both Class I and Class II appliances. Its intuitive interface, combined with a clear, backlit display, simplifies testing procedures, reduces user error, and speeds up inspection workflows.

Designed for fieldwork, the PAT150R-UK is compact, lightweight, and rugged, making it ideal for use in commercial, industrial, and domestic environments. The tester’s durable construction ensures it can withstand the demands of daily on-site inspections, while its ergonomic design allows for comfortable operation over extended periods.

With the Megger PAT150R-UK, technicians can confidently perform routine inspections, maintenance checks, and compliance testing, knowing they will obtain accurate, repeatable results every time. This portable tester is perfect for managing appliance safety programs, maintaining records, and ensuring that electrical equipment meets strict regulatory standards.

Whether you are responsible for individual devices or overseeing large-scale appliance testing across multiple sites, the Megger PAT150R-UK delivers professional performance, reliability, and peace of mind for every safety-conscious electrician.

Megger PAT150R-UK Key Features

  • Comprehensive appliance safety testing: earth continuity, insulation resistance, polarity, and leakage current.
  • Suitable for both Class I and Class II appliances.
  • Clear, backlit display for easy reading in any environment.
  • Simple, intuitive interface for fast and error-free testing.
  • Lightweight and portable design, ideal for on-site inspections.
  • Rugged construction for reliable use in industrial, commercial, and domestic settings.
  • Automatic and manual testing modes to streamline workflows.
  • Generates repeatable and accurate test results for compliance assurance.

Technical Highlights

Test Types: Earth continuity, insulation resistance, polarity, leakage current.
Measurement Range: Designed for Class I and Class II appliances.
Display: Clear backlit LCD for easy visibility of readings.
Test Modes: Automatic sequences or step-by-step manual testing.
Data Handling: Stores and records results for compliance and reporting purposes.
Power Supply: Internal rechargeable or standard batteries for portable operation.
Safety Standards: Fully compliant with UK PAT regulations and IEC 61010 safety requirements.
Durability: Rugged design suitable for field conditions and daily use.

What’s in the Box Megger PAT150R-UK

  • Megger PAT150R-UK Portable Appliance Tester
  • Test leads and crocodile clips
  • Mains lead for testing
  • User manual / quick start guide
  • Carry case
Datasheet

Datasheet

Mme-pdfs-image

Specifications

Specifications

Environmental Condition

Parameter Value
Operating ambient 20 °C
Humidity 45% RH ± 20 points

Continuity Test

Parameter Details
Test voltage +4 V DC (open circuit, -0% / +30%)
Test current Bi-directional +200 mA (-0% +50 mA into 2 Ω load)
Accuracy Resistance ±5% ±3 digits (0–19.99 Ω)
Resolution 10 mΩ
Display range 0.01–19.99 Ω
Nulling Up to 9.99 Ω
Test time User selectable 2–20 s or up to 180 s

Insulation Test

Parameter Details
Test voltage 250 V DC (-0% +25%), 500 V DC (-0% +25%)
Short-circuit/charge current <2 mA DC
Accuracy ±3% ±10 digits (0–19.99 MΩ)
Resolution 0.01 MΩ
Display range 0.10–99.99 MΩ
Test duration User selectable 2–20 s or up to 180 s

Substitute Leakage Test

Parameter Details
Accuracy ±5% ±3 digits
Test frequency 50 Hz (nominal mains)
Test voltage <50 V AC
Resolution 0.01 mA
Display range 0.10–19.99 mA
Duration User selectable 2–5 s
Note Reading corrected to 230 V AC

Differential Leakage Current

Parameter Details
Test voltage 230 V AC (nominal)
Test frequency 50 Hz
Accuracy ±5% ±3 digits ±3 µA/A
Resolution 0.01 mA
Display range 0.10–19.99 mA
Duration User selectable 2–5 s

Touch Current Test

Parameter Details
Test voltage 230 V AC (nominal mains)
Test frequency 50 Hz
Accuracy ±5% ±3 digits
Resolution 0.01 mA
Display range 0.10–3.99 mA
Duration User selectable 2–5 s

SELV Device Test

Parameter Details
Test voltage 0–300 V AC
Accuracy ±3% ±3 digits
Resolution 0.1 V AC
Display range 0.1–300 V AC

Extension Lead Test

Test Details
Test voltage 5 V
Polarity Lead OK
Checks Live/neutral shorted, reversed, open circuit

Extension Portable RCD Test

Parameter Details
Test voltage 230 V (nominal mains)
Test frequency 50 Hz
Current accuracy +2% to +8% (1 × I, 5 × I)
Trip time accuracy ±1% ±1 ms
Resolution 0.01 ms
Display range 0–200 ms (1 × I), 0–40 ms (5 × I)

Main Supply Test

Parameter Details
Frequency range 50 Hz
Test voltage 40–300 V AC
Accuracy ±3% ±3 digits
Resolution 0.1 V AC
Display range 40–300 V AC

Circuit Test

Parameter Details
Test voltage 5 V
Test frequency 50 Hz (nominal mains)
Test current <100 mA short-circuit
Note Carried out automatically, not available to user

Safety

  • Instrument: IEC 61010-1:2012
  • Test leads: IEC 61010-031:2005
  • PAT150: 300 V to Earth Category II
  • Mains fuse protection: 250 V rms AC

EMC

  • IEC 61326-1:2012
  • IEC 61326-2-2:2012

Fuse

  • User replaceable fuse: 13 A fused mains plug (PAT150-UK only)
  • One F 100 mA 250 V 5×20 mm HBC

Environmental

Condition Value
Operating temperature 0 °C to +40 °C
Storage temperature -20 °C to +60 °C
Operating humidity 90% RH @ +10 °C to +30 °C; 75% RH up to +60 °C
Altitude Up to 2000 m
IP rating IP40 (front cover closed)

Mechanical

Specification Details
Battery life Over 1000 full Class 1 tests (3400 mAh alkaline)
Battery type 8 × AA LR6 cells (12 V DC alkaline / 9.6 V DC NiMH)
PAT120 weight (instrument) 1150 g (40.4 oz)
PAT120 weight (shipping) 2370 g (83.6 oz)
PAT150 weight (instrument) 1300 g (45.8 oz)
PAT150 weight (shipping) 2975 g (104.9 oz)

Dimensions

Type Dimensions
Instrument & case 203 × 148 × 78 mm (8 × 5.7 × 3.2 in)
Instrument & packaging 456 × 178 × 89 mm (18 × 7.1 × 3.5 in)
Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Megger PAT150R-UK Portable Appliance Tester”