Megger PAT350 Portable Appliance Tester
The Megger PAT350 is a portable appliance tester used for electrical safety testing of portable appliances.
This instrument is essentially the same as the PAT320 but includes a flash-test capability, making it ideal for environments like manufacturing, production, or tool-hire shops. Besides automatic testing, it can perform each test individually, which is particularly useful for service and repair organizations engaged in fault diagnostics.
Megger PAT350 Key Features
- Simple manual or automatic testing
- 230 V and 110 V operation
- Bond testing at 25 A,10 A, and 200 mA
- Full colour display
- Tests portable RCDs and extension leads
- Differential, touch, and substitute leakage testing
- Pre-set test sequences for Class I, Class II, and extension leads
- Flash Testing at 1.5 kV and 3 kV
- Tests to DIN VDE 0701-0702
Megger PAT350 Specifications
FEATURE | SPECIFICATION |
---|---|
Electrical Supply Range | 230 V ±10% ±1 V @ 50 Hz ±10% ±0.1 Hz |
Instrument Accuracy | Accuracy not guaranteed outside specified supply frequencies |
Bond Test (10 A and 25 A) | Open circuit voltage: 9 V a.c. ±10% ±0.1 V (Supply: 230 V 50 Hz)<br>Earth bond resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 1.99 Ω)<br>Resolution: 10 mΩ (0 to 1.99 Ω)<br>Display range: 10 to 1.99 Ω |
Continuity | Test voltage: 4.0 V d.c. -0% +10<br>Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 19.99 Ω)<br>Resolution: 10 mΩ (1 to 19.99 Ω)<br>Display range: 0 to 19.99 Ω |
Insulation Test (250 V & 500 V) | Accuracy (230 V): ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)<br>Resolution: 0.01 MΩ<br>Display range: 0 to 99.99 MΩ |
Substitute Leakage Current | Test voltage and frequency: 40 V a.c. ±10% @ nominal mains frequency<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Leakage Current | Test voltage: Nominal mains supply<br>Accuracy: ±5% ± 5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Touch Current Test | Test voltage: Nominal main supply<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0.00 to 10 mA |
Operational Test | Test voltage: Nominal mains supply<br>VA Accuracy: ±5% ±10 digits (0 to 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 3700 VA)<br>Resolution: 1 VA<br>Display range: 0 to 3.99 KVA |
Ext Lead Test | Test performed: Bond insulation and polarity<br>Polarity test voltage: 12 V dc<br>Polarity outcomes: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C |
Flash Test (PAT350) | Voltage: 1500 V a.c nominal for Class I, 3000 V a.c nominal for Class II<br>Current: < 3.5 mA short circuit @ 253 V primary supply voltage<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 3.0 mA |
RCD Tests | Voltage and frequency: Nominal mains supply<br>Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)<br>Trip time accuracy: ±1% ±5 digits<br>Resolution: 0.1 ms<br>Display ranges: Various |
Fuse Test | Voltage: 3.3 V<br>Indicator: Audible beep if fuse is OK |
Temperature and Humidity | Operating: -10 to +50 °C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C<br>Storage: -20 to +60° C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C |
Weight | PAT310: 3.2 kg, PAT320: 4.9 kg, PAT350: 5.5 kg |
Dimensions | PAT350: 155mm (H) x 255 mm (W) x 320 mm (L) |
You must be logged in to post a review.
Brand
Megger
Megger
Megger since 1889 is a leading global premium manufacturer of measurement and testing technology. Megger top priority has always been to make your everyday work easier and safer. As such, insulation testers, micro-ohmmeters, and multimeters are among the long line of Megger inventions, making this brand one of the pioneers in the electrical industry. Megger products combine many years of experience and the valued feedback from our global users with the inventiveness and conscientiousness of our product developers. In Germany, we manufacture at three sites, Aachen, and Baunach near Bamberg and Radeburg near Dresden. Other manufacturing locations are based in Sweden, England, and America.
![Megger logo brand](https://mme-ae.com/wp-content/themes/woodmart/images/lazy.png)
Specifications
FEATURE | SPECIFICATION |
---|---|
Electrical Supply Range | 230 V ±10% ±1 V @ 50 Hz ±10% ±0.1 Hz |
Instrument Accuracy | Accuracy not guaranteed outside specified supply frequencies |
Bond Test (10 A and 25 A) | Open circuit voltage: 9 V a.c. ±10% ±0.1 V (Supply: 230 V 50 Hz)<br>Earth bond resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 1.99 Ω)<br>Resolution: 10 mΩ (0 to 1.99 Ω)<br>Display range: 10 to 1.99 Ω |
Continuity | Test voltage: 4.0 V d.c. -0% +10<br>Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 19.99 Ω)<br>Resolution: 10 mΩ (1 to 19.99 Ω)<br>Display range: 0 to 19.99 Ω |
Insulation Test (250 V & 500 V) | Accuracy (230 V): ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)<br>Resolution: 0.01 MΩ<br>Display range: 0 to 99.99 MΩ |
Substitute Leakage Current | Test voltage and frequency: 40 V a.c. ±10% @ nominal mains frequency<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Leakage Current | Test voltage: Nominal mains supply<br>Accuracy: ±5% ± 5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Touch Current Test | Test voltage: Nominal main supply<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0.00 to 10 mA |
Operational Test | Test voltage: Nominal mains supply<br>VA Accuracy: ±5% ±10 digits (0 to 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 3700 VA)<br>Resolution: 1 VA<br>Display range: 0 to 3.99 KVA |
Ext Lead Test | Test performed: Bond insulation and polarity<br>Polarity test voltage: 12 V dc<br>Polarity outcomes: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C |
Flash Test (PAT350) | Voltage: 1500 V a.c nominal for Class I, 3000 V a.c nominal for Class II<br>Current: < 3.5 mA short circuit @ 253 V primary supply voltage<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 3.0 mA |
RCD Tests | Voltage and frequency: Nominal mains supply<br>Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)<br>Trip time accuracy: ±1% ±5 digits<br>Resolution: 0.1 ms<br>Display ranges: Various |
Fuse Test | Voltage: 3.3 V<br>Indicator: Audible beep if fuse is OK |
Temperature and Humidity | Operating: -10 to +50 °C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C<br>Storage: -20 to +60° C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C |
Weight | PAT310: 3.2 kg, PAT320: 4.9 kg, PAT350: 5.5 kg |
Dimensions | PAT350: 155mm (H) x 255 mm (W) x 320 mm (L) |
Related Products
Fluke 289 TRMS Epic Logging Multimeter with TrendCapture
In stock
Fluke 287 True-RMS Electronics Logging Multimeter
In stock
Fluke 378 FC Voltage AC/DC Clamp Meter
In stock
Fluke 381 True RMS Clamp Meter
In stock
Fluke 375 AC/DC Clamp Meter
In stock
Fluke 179 True RMS Digital Multimeter
In stock
Reviews
Clear filtersThere are no reviews yet.