Megger PAT320 Portable Appliance Tester
Short Description:
Dubai, UAE residents – Looking to buy Megger PAT320? Find the best deals and prices here. Improve your measurement accuracy today!
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Megger PAT320 Portable Appliance Tester
The Megger PAT320 is a portable appliance tester designed for thorough and efficient electrical safety testing of a wide range of appliances.
The PAT320 is the ideal PAT tester for those seeking high productivity in a robust and user-friendly instrument. It features dedicated test buttons for direct access to various tests and is perfect for users who don’t need a fully configurable database of clients and results within the tester but require a complete range of functions for both automatic and manual testing of a wide array of electrical assets. Whether you’re new to PAT testing or prefer to avoid the complexities of database management, the PAT320 is an excellent choice.
Megger PAT320 Key Features
- Simple manual or automatic testing
- 230 V and 110 V operation
- Bond testing at 25 A,10 A, and 200 mA
- Full colour display
- Tests portable RCDs and extension leads
- Differential, touch, and substitute leakage testing
- Pre-set test sequences for Class I, Class II, and extension leads
- Flash Testing at 1.5 kV and 3 kV
- Tests to DIN VDE 0701-0702
Megger PAT320 Specifications
Feature | Specification |
---|---|
Electrical Supply Range | 230 V ±10% ±1 V @ 50 Hz ±10% ±0.1 Hz |
Instrument Accuracy | Accuracy not guaranteed outside specified supply frequencies |
Bond Test (10 A and 25 A) | Open circuit voltage: 9 V a.c. ±10% ±0.1 V (Supply: 230 V 50 Hz)<br>Earth bond resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 1.99 Ω)<br>Resolution: 10 mΩ (0 to 1.99 Ω)<br>Display range: 10 to 1.99 Ω |
Continuity | Test voltage: 4.0 V d.c. -0% +10<br>Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 19.99 Ω)<br>Resolution: 10 mΩ (1 to 19.99 Ω)<br>Display range: 0 to 19.99 Ω |
Insulation Test (250 V & 500 V) | Accuracy (230 V): ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)<br>Resolution: 0.01 MΩ<br>Display range: 0 to 99.99 MΩ |
Substitute Leakage Current | Test voltage and frequency: 40 V a.c. ±10% @ nominal mains frequency<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Leakage Current | Test voltage: Nominal mains supply<br>Accuracy: ±5% ± 5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Touch Current Test | Test voltage: Nominal main supply<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0.00 to 10 mA |
Operational Test | Test voltage: Nominal mains supply<br>VA Accuracy: ±5% ±10 digits (0 to 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 3700 VA)<br>Resolution: 1 VA<br>Display range: 0 to 3.99 KVA |
Ext Lead Test | Test performed: Bond insulation and polarity<br>Polarity test voltage: 12 V dc<br>Polarity outcomes: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C |
Flash Test (PAT350) | Voltage: 1500 V a.c nominal for Class I, 3000 V a.c nominal for Class II<br>Current: < 3.5 mA short circuit @ 253 V primary supply voltage<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 3.0 mA |
RCD Tests | Voltage and frequency: Nominal mains supply<br>Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)<br>Trip time accuracy: ±1% ±5 digits<br>Resolution: 0.1 ms<br>Display ranges: Various |
Fuse Test | Voltage: 3.3 V<br>Indicator: Audible beep if fuse is OK |
Temperature and Humidity | Operating: -10 to +50 °C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C<br>Storage: -20 to +60° C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C |
Weight | PAT310: 3.2 kg, PAT320: 4.9 kg, PAT350: 5.5 kg |
Dimensions | PAT320: 155mm (H) x 255 mm (W) x 320 mm (L) |
Specifications
Feature | Specification |
---|---|
Electrical Supply Range | 230 V ±10% ±1 V @ 50 Hz ±10% ±0.1 Hz |
Instrument Accuracy | Accuracy not guaranteed outside specified supply frequencies |
Bond Test (10 A and 25 A) | Open circuit voltage: 9 V a.c. ±10% ±0.1 V (Supply: 230 V 50 Hz)<br>Earth bond resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 1.99 Ω)<br>Resolution: 10 mΩ (0 to 1.99 Ω)<br>Display range: 10 to 1.99 Ω |
Continuity | Test voltage: 4.0 V d.c. -0% +10<br>Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 19.99 Ω)<br>Resolution: 10 mΩ (1 to 19.99 Ω)<br>Display range: 0 to 19.99 Ω |
Insulation Test (250 V & 500 V) | Accuracy (230 V): ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)<br>Resolution: 0.01 MΩ<br>Display range: 0 to 99.99 MΩ |
Substitute Leakage Current | Test voltage and frequency: 40 V a.c. ±10% @ nominal mains frequency<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Leakage Current | Test voltage: Nominal mains supply<br>Accuracy: ±5% ± 5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 19.99 mA |
Touch Current Test | Test voltage: Nominal main supply<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0.00 to 10 mA |
Operational Test | Test voltage: Nominal mains supply<br>VA Accuracy: ±5% ±10 digits (0 to 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 3700 VA)<br>Resolution: 1 VA<br>Display range: 0 to 3.99 KVA |
Ext Lead Test | Test performed: Bond insulation and polarity<br>Polarity test voltage: 12 V dc<br>Polarity outcomes: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C |
Flash Test (PAT350) | Voltage: 1500 V a.c nominal for Class I, 3000 V a.c nominal for Class II<br>Current: < 3.5 mA short circuit @ 253 V primary supply voltage<br>Accuracy: ±5% ±5 digits<br>Resolution: 0.01 mA<br>Display range: 0 to 3.0 mA |
RCD Tests | Voltage and frequency: Nominal mains supply<br>Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)<br>Trip time accuracy: ±1% ±5 digits<br>Resolution: 0.1 ms<br>Display ranges: Various |
Fuse Test | Voltage: 3.3 V<br>Indicator: Audible beep if fuse is OK |
Temperature and Humidity | Operating: -10 to +50 °C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C<br>Storage: -20 to +60° C, 90% RH @ -10 to +30 °C, 75% RH @ +30 to +50 °C |
Weight | PAT310: 3.2 kg, PAT320: 4.9 kg, PAT350: 5.5 kg |
Dimensions | PAT320: 155mm (H) x 255 mm (W) x 320 mm (L) |