The Megger PAT150 is a series of handheld portable appliance testers designed for electrical safety testing of electrical appliances and equipment.

The PAT100 series of handheld portable appliance testers is designed for quick and easy safety testing in various environments, including offices, shops, and business units. These testers are durable, reliable, and user-friendly, making them ideal for training organizations with intensive courses.

Featuring rubber-armored cases and scratch-resistant hardened glass, the PAT100s are exceptionally rugged. Their battery-powered operation makes them perfect for locations without a readily available, convenient, or safe electrical supply, such as building sites and warehouses. The PAT100 series complies with all UK and European electrical safety testing standards.

Megger PAT150 Key Features

  • Simple ‘tick/cross’ or ‘pass/fail’ indication plus measurement
  • Tough, rubber armoured with built-in front cover, hardened, scratch-proof display window
  • Includes 250 V insulation and leakage testing for safe IT testing and surge protected devices
  • Testing portable and fixed electrical equipment
  • 10 mA and 30 mA portable RCD lead testing (PAT150)
  • Adjustable PASS test limits (PAT150)
  • Substitute and mains powered leakage testing (PAT150)
  • Battery powered with rechargeable options

Megger PAT150 Specifications

General Specifications

FEATURE SPECIFICATION
Operating Temperature 0 °C to +40 °C (32 °F to 104 °F)
Storage Temperature -20 °C to +60 °C (4 °F to 140 °F)
Humidity 90% RH @ +10 °C to +30 °C, 75% RH @ +30 °C to +60 °C
Operating Altitude Up to 2,000m
IP Rating IP40 (with front cover closed)
Battery Type Eight AA LR6 cells, 12 V dc (Alkaline), 9.6 V dc (NiMH)
Weight (PAT120) 1150g (instrument), 2370g (shipping)
Weight (PAT150) 1300g (instrument), 2975g (shipping)
Dimensions (Instrument and Case) 203 mm L x 148 mm W x 78 mm H (8 x 5.7 x 3.2 inches)
Dimensions (Instrument and Packaging) 456 mm L x 178 mm W x 89 mm H (18 x 7.1 x 3.5 inches)

Test Capabilities and Specifications

TEST SPECIFICATIONS
Continuity Test Voltage: +4 V dc -0% / +30%, Current: +200 mA -0 % + 50 mA, Accuracy: ± 5% ± 3 digits, Resolution: 10 mΩ, Display Range: 0.01 to 19.99 Ω
Insulation Test Voltage: 250 V dc and 500 V dc -0% +25%, Accuracy: ± 3% ± 10 digits, Display Range: 0.10 MΩ to 99.99 MΩ
Substitute Leakage Test Voltage: < 50V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits, Resolution: 0.01 mA, Display Range: 0.10 to 19.99 mA
Differential Leakage Current Voltage: 230 V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits ± 3 uA/A, Display Range: 0.10 to 19.99 mA
Touch Current Test Voltage: 230 V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits, Display Range: 0.10 to 3.99 mA
SELV Device Test Voltage: 0 to 300 V ac, Accuracy: ± 3% ± 3 digits, Display Range: 0.1 to 300 V ac
Extension Lead Test Voltage: 5 V, Conditions: Polarity Lead OK, Live/neutral shorted, reversed, open circuit
Portable RCD Test Voltage: 230 V, Frequency: 50 Hz, Current Accuracy: +2 % to +8 %, Trip Time Accuracy: ± 1 % ± 1 ms, Display Range: 0 to 200 ms (1 x I), 0 to 40 ms (5 x I)
Main Supply Test Frequency: 50 Hz, Voltage: 40 to 300 V ac, Accuracy: ± 3% ± 3 digits, Display Range: 40 to 300 V ac
Safety and Compliance Designed to IEC 61010-1: 2012, Test leads to IEC 61010-031: 2005, Mains fuse protection to 250 V rms ac, EMC compliant with IEC 61326-1: 2012, IEC 61326-2-2: 2012
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Megger PAT150 Handheld Portable Appliance Testers”

Brand

Megger

Megger

Megger since 1889 is a leading global premium manufacturer of measurement and testing technology. Megger top priority has always been to make your everyday work easier and safer. As such, insulation testers, micro-ohmmeters, and multimeters are among the long line of Megger inventions, making this brand one of the pioneers in the electrical industry. Megger products combine many years of experience and the valued feedback from our global users with the inventiveness and conscientiousness of our product developers. In Germany, we manufacture at three sites, Aachen, and Baunach near Bamberg and Radeburg near Dresden. Other manufacturing locations are based in Sweden, England, and America.

Megger logo brand

Datasheet

Mme-Pdfs-Image

Specifications

General Specifications

FEATURE SPECIFICATION
Operating Temperature 0 °C to +40 °C (32 °F to 104 °F)
Storage Temperature -20 °C to +60 °C (4 °F to 140 °F)
Humidity 90% RH @ +10 °C to +30 °C, 75% RH @ +30 °C to +60 °C
Operating Altitude Up to 2,000m
IP Rating IP40 (with front cover closed)
Battery Type Eight AA LR6 cells, 12 V dc (Alkaline), 9.6 V dc (NiMH)
Weight (PAT120) 1150g (instrument), 2370g (shipping)
Weight (PAT150) 1300g (instrument), 2975g (shipping)
Dimensions (Instrument and Case) 203 mm L x 148 mm W x 78 mm H (8 x 5.7 x 3.2 inches)
Dimensions (Instrument and Packaging) 456 mm L x 178 mm W x 89 mm H (18 x 7.1 x 3.5 inches)

Test Capabilities and Specifications

TEST SPECIFICATIONS
Continuity Test Voltage: +4 V dc -0% / +30%, Current: +200 mA -0 % + 50 mA, Accuracy: ± 5% ± 3 digits, Resolution: 10 mΩ, Display Range: 0.01 to 19.99 Ω
Insulation Test Voltage: 250 V dc and 500 V dc -0% +25%, Accuracy: ± 3% ± 10 digits, Display Range: 0.10 MΩ to 99.99 MΩ
Substitute Leakage Test Voltage: < 50V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits, Resolution: 0.01 mA, Display Range: 0.10 to 19.99 mA
Differential Leakage Current Voltage: 230 V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits ± 3 uA/A, Display Range: 0.10 to 19.99 mA
Touch Current Test Voltage: 230 V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits, Display Range: 0.10 to 3.99 mA
SELV Device Test Voltage: 0 to 300 V ac, Accuracy: ± 3% ± 3 digits, Display Range: 0.1 to 300 V ac
Extension Lead Test Voltage: 5 V, Conditions: Polarity Lead OK, Live/neutral shorted, reversed, open circuit
Portable RCD Test Voltage: 230 V, Frequency: 50 Hz, Current Accuracy: +2 % to +8 %, Trip Time Accuracy: ± 1 % ± 1 ms, Display Range: 0 to 200 ms (1 x I), 0 to 40 ms (5 x I)
Main Supply Test Frequency: 50 Hz, Voltage: 40 to 300 V ac, Accuracy: ± 3% ± 3 digits, Display Range: 40 to 300 V ac
Safety and Compliance Designed to IEC 61010-1: 2012, Test leads to IEC 61010-031: 2005, Mains fuse protection to 250 V rms ac, EMC compliant with IEC 61326-1: 2012, IEC 61326-2-2: 2012