Description

Megger PAT450 Portable Appliance Tester

The Megger PAT450 Portable Appliance Tester is a device used for checking the safety and effectiveness of electrical appliances and equipment. It can test portable electrical equipment to ensure they comply with electrical safety standards, and it’s commonly used in commercial and industrial maintenance to ensure workplace safety.

These devices support both manual and automatic modes of operation. In automatic mode, the configuration of the test sequence can be easily customized to meet specific needs. For instance, a supervisor can set up a test sequence tailored for a specific task, ensuring that all tests are conducted consistently and correctly, no matter who performs them.

Megger PAT450 Key Features

  • Store up to 10 000 results
  • Selectable PASS/FAIL limits
  • 200 mA, 10 A, and 25 A bond testing

Megger PAT450 Specifications

Specification Details
Electrical Supply Range 120 V ± 10%
Bond Test (10 A and 25 A) Open circuit voltage: 9 V a.c. ± 10% ± 0.1 V
Earth Bond Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 0.99 Ω)
Earth Bond Resistance Resolution 10 mΩ (0 to 1.99 Ω)
Display Range (Bond Test) 0 to 1.99 Ω
Continuity Test (200 mA) Voltage: 4.0 V d.c. -0% +10%
Continuity Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 0.99 Ω)
Continuity Resistance Resolution 10 mΩ (1 to 19.99 Ω)
Display Range (Continuity Test) 0 to 19.99 Ω
Insulation Resistance Test 250 V and 500 V
Insulation Resistance Accuracy ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
Resolution (Insulation Test) 0.01 MΩ
Display Range (Insulation Test) 0 to 99.99 MΩ
Leakage Current Test Details Test voltage/frequency: 40 V ac ±10% nominal mains frequency
Leakage Current Accuracy ±5% ±5 digits
Leakage Current Resolution 0.01 mA
Display Range (Leakage Current) 0 to 19.99 mA
Differential Leakage Current Test voltage and frequency: Nominal mains supply
Touch Current Test Accuracy: ±5% ±5 digits, Resolution: 0.01 mA, Display range: 0 to 10 mA
Operational Test Test voltage and frequency: Nominal mains supply, VA rating: 110 V 1800 VA
VA Accuracy ±5% ±10 digits (0 – 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 1800 VA)
VA Resolution 1 VA (0 to 1800 VA)
Display Range (Operational Test) 0 to 1800 VA
Extension Lead Test Bond, insulation, and polarity
Hi-pot/Flash Test Voltage: 1500 V ac for Class 1, 3000 V ac for Class 2
Fuse Test Voltage: 3.3 V, Warning: Audible beep if fuse is OK
Environmental Conditions Operating temp: -10 to +50 ºC, Storage temp: -20 to +60 ºC
Humidity 90% RH @ -10 to +30 ºC, 75% RH @ +30 to +50 ºC
Maximum Altitude 2000 m
Ingress Protection IP40
Weight 5.0 kg (11 lb)
Dimensions (Instrument) 180 (H) x 255 (W) x 320 (L) mm
Dimensions (Packaging) 210 (H) x 280 (W) x 390 (L) mm
Datasheet

Datasheet

Mme-Pdfs-Image

Specifications

Specifications

Specification Details
Electrical Supply Range 120 V ± 10%
Bond Test (10 A and 25 A) Open circuit voltage: 9 V a.c. ± 10% ± 0.1 V
Earth Bond Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 0.99 Ω)
Earth Bond Resistance Resolution 10 mΩ (0 to 1.99 Ω)
Display Range (Bond Test) 0 to 1.99 Ω
Continuity Test (200 mA) Voltage: 4.0 V d.c. -0% +10%
Continuity Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits (0.5 to 0.99 Ω)
Continuity Resistance Resolution 10 mΩ (1 to 19.99 Ω)
Display Range (Continuity Test) 0 to 19.99 Ω
Insulation Resistance Test 250 V and 500 V
Insulation Resistance Accuracy ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
Resolution (Insulation Test) 0.01 MΩ
Display Range (Insulation Test) 0 to 99.99 MΩ
Leakage Current Test Details Test voltage/frequency: 40 V ac ±10% nominal mains frequency
Leakage Current Accuracy ±5% ±5 digits
Leakage Current Resolution 0.01 mA
Display Range (Leakage Current) 0 to 19.99 mA
Differential Leakage Current Test voltage and frequency: Nominal mains supply
Touch Current Test Accuracy: ±5% ±5 digits, Resolution: 0.01 mA, Display range: 0 to 10 mA
Operational Test Test voltage and frequency: Nominal mains supply, VA rating: 110 V 1800 VA
VA Accuracy ±5% ±10 digits (0 – 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 1800 VA)
VA Resolution 1 VA (0 to 1800 VA)
Display Range (Operational Test) 0 to 1800 VA
Extension Lead Test Bond, insulation, and polarity
Hi-pot/Flash Test Voltage: 1500 V ac for Class 1, 3000 V ac for Class 2
Fuse Test Voltage: 3.3 V, Warning: Audible beep if fuse is OK
Environmental Conditions Operating temp: -10 to +50 ºC, Storage temp: -20 to +60 ºC
Humidity 90% RH @ -10 to +30 ºC, 75% RH @ +30 to +50 ºC
Maximum Altitude 2000 m
Ingress Protection IP40
Weight 5.0 kg (11 lb)
Dimensions (Instrument) 180 (H) x 255 (W) x 320 (L) mm
Dimensions (Packaging) 210 (H) x 280 (W) x 390 (L) mm