Fluke 376 True RMS AC/DC Clamp Meter with iFlex

The Fluke 376 True RMS AC/DC Clamp Meter with iFlex is a versatile electrical testing tool commonly used by electricians, technicians, and engineers for measuring various parameters in both AC (Alternating Current) and DC (Direct Current) circuits.

SKU: 79246

Call for Price

We are not Supporting COD Payments Terms Outside UAE

14 People watching this product now!

Fluke 376 True RMS AC/DC Clamp Meter with iFlex®

The Fluke 376 True RMS AC/DC Clamp Meter with iFlex is designed for professionals who require accurate and versatile current measurement capabilities. This advanced tool combines True RMS technology with the flexibility of the iFlex current probe, making it an essential device for a wide range of electrical applications.

Fluke 376 review

The Fluke 376 True RMS clamp meter ensures precise and reliable measurements of both AC and DC currents, even in environments with noisy electrical signals. True RMS technology provides accurate readings for non-linear loads, which are common in modern electrical systems.

The included iFlex flexible current probe expands the measurement range to 2500 A AC while providing increased flexibility. This feature allows you to measure large conductors and cables in tight and hard-to-reach spaces, enhancing the meter’s versatility and usability.

With the ability to measure up to 1000 A AC/DC, the Fluke 376 is suitable for a variety of industrial and commercial applications. This high measurement capability ensures that you can handle both small and large current measurements with confidence.

Safety is paramount with the Fluke 376, which is rated CAT IV 600 V, CAT III 1000 V. These safety ratings ensure that the meter can be used in demanding electrical environments without compromising user safety. Its rugged construction guarantees durability, making it a reliable tool for everyday use.

The Fluke 376 features a large, easy-to-read backlit display, ensuring that measurements can be read clearly in any lighting condition. The ergonomic design makes it comfortable to hold and operate, reducing user fatigue during extended use.

In addition to current measurements, the Fluke 376 True RMS clamp meter can measure voltage, frequency, and resistance, providing a comprehensive solution for various electrical testing needs. This multifunctionality makes it a versatile tool for electricians, maintenance technicians, and engineers.

For those looking to buy Fluke 376 clamp meter, it’s important to consider the Fluke 376 clamp meter price and read Fluke 376 reviews to ensure it meets your requirements. You can conveniently buy clamp meter in UAE through the mme-ae website, which offers a range of Fluke products. Explore the Fluke 376 features and experience the difference that a high-quality clamp meter can make in your electrical testing and troubleshooting tasks.

Fluke 376 features:

  • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
  • CAT IV 600 V, CAT III 1000 V
  • True RMS AC voltage and current for accurate measurements on non-linear signals
  • Min, max, average and Inrush recording to capture variations automatically
  • Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary Inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft Carrying Case

Fluke 376 Clamp Meter Specifications:

Electrical Specifications
AC Current via Jaw
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 374 and 375 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
376 0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
Flexible Current Probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits
mV dc
Range 375 and 376 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 375 and 376 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 375 and 376 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 374
375 and 376
6000 Ω
60 kΩ
Resolution 374 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals
Batteries 2 AA, NEDA 15A, IEC LR6
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Fluke 376 True RMS AC/DC Clamp Meter with iFlex”

Brand

Fluke

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.
Fluke logo brand

Datasheet

Mme-Pdfs-Image

Specifications

 

Parameter 374 and 375 376
Range 600.0 A / 999.9 A 600.0 A / 999.9 A
Resolution 0.1 A 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2% for C.F. > 2 Yes Yes

AC Current via Flexible Current Probe

Parameter 374 and 375 376
Range 2500 A 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ± 5 digits (5 – 500 Hz) 3% ± 5 digits (5 – 500 Hz)
Crest Factor (50/60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2 Yes Yes

DC Current

Parameter 374 and 375 376
Range 600.0 A / 999.9 A 600.0 A / 999.9 A
Resolution 0.1 A 0.1 A
Accuracy 2% ± 5 digits 2% ± 5 digits

AC Voltage

Parameter 374 and 375 376
Range 600.0 V / 1000 V 600.0 V / 1000 V
Resolution 0.1 V 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz) 1.5% ± 5 digits (20 – 500 Hz)

DC Voltage

Parameter 374 and 375 376
Range 600.0 V / 1000 V 600.0 V / 1000 V
Resolution 0.1 V 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits 1% ± 5 digits

mV DC

Parameter 375 and 376
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits

Frequency via Jaw

Parameter 375 and 376
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A

Frequency via Flexible Current Probe

Parameter 375 and 376
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A

Resistance

<tr

Parameter 374 375 and 376