Hioki 3153 Automatic Insulation Hitester
Short Description:
Hioki 3153 Key Features :
- Programmable insulation and dielectric strength testing
- Program up to 32 files of test types, test points , and measurement settings
- Optional scanner for multipoint automatic testing
- Uses the PWM method to generate accurate test voltages that do not depend on the supply voltage
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
13
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Hioki Automatic Insulation Hitester 3153
The Hioki LR8450 Memory HiLogger exemplifies cutting-edge technology in electrical safety testing, offering unmatched capabilities for insulation resistance and voltage withstand testing. Designed to meet a wide array of safety standards, this device is essential for ensuring the electrical safety and reliability of devices and components across various industries.
Advanced Testing Features of the Hioki LR8450 Memory HiLogger:
- Programmable Testing Options: The Hioki LR8450 allows users to precisely control their testing processes. It can program up to 32 files containing specific test types, test points, and measurement settings. This high level of programmability facilitates customized testing tailored to unique requirements, enhancing the device’s flexibility and utility in complex testing scenarios.
- Automated and Efficient Testing: Equipped with capabilities for fully automated testing, the Hioki LR8450 integrates seamlessly into production lines and laboratories where efficiency and accuracy are paramount. The automation supports consistent and reliable testing, crucial for maintaining high standards of quality and safety.
- Multipoint Testing Capability: An optional scanner can be attached to the Hioki LR8450, enabling multipoint automatic testing. This feature is particularly beneficial for comprehensive evaluations of multi-component systems or complex assemblies, ensuring thorough coverage and significantly improving testing throughput.
- Precision Voltage Generation: Utilizing the Pulse Width Modulation (PWM) method to generate test voltages, the Hioki LR8450 ensures that these voltages are highly accurate and stable, irrespective of fluctuations in the supply voltage. This precision is critical for valid and reliable insulation and dielectric strength tests, where accurate voltage application is key to determining the safety and efficacy of electrical components.
- Compliance with Safety Standards: The Hioki LR8450 is designed to conduct tests in strict accordance with various international safety standards. This compliance guarantees that tested components and devices are safe for use and meet all regulatory requirements for electrical safety.
Hioki 3153 Specifications:
- Testing voltage:0.2 kV to 5.00 kV AC, 500 VA
- Voltage setting: Digital setting
- Waveform:Sine wave
- Frequency: 50/60 Hz
- Current measurement:0.01 mA to 100.0 mA, Average rectified display
- Measurement range:10 mA , 100 mA
Specifications
Category | Specification | Details |
---|---|---|
Basic Specifications | Functions | Program up to 32 files of 50 step test settings, 10 sets each of dielectric strength and insulation test settings, hold, buzzer |
Monitor Functions | Output voltage, detected current, measured resistance, Refresh rate: 2 times/s | |
Power Supply | 100 to 120 V, 200 to 240 V AC, (50/60 Hz), 1000 VA max. | |
Dimensions and Mass | 320 mm (12.60 in) W × 155 mm (6.10 in) H × 480 mm (18.9 in) D, 18 kg (634.9 oz) | |
Withstanding Test | Testing Voltage AC/DC | 0.2 kV to 5.00 kV AC, 500 VA (max. 30 minutes), 0.2 kV to 5.00 kV DC, 50 VA (continuance) |
Voltage Setting | Digital setting (0.01 kV resolution) | |
Waveform/Frequency | Sine wave (5% or less distortion, unloaded), 50/60 Hz selectable | |
Current Measurement | 0.01 mA to 100.0 mA, Average rectified display (Digital) | |
Voltmeter | Digital: accuracy ±1.5 % f.s. (f.s.=5.00 kV) (Average rectified display) | |
Insulation Test | Rated Testing Voltage | 50 to 1,200 V DC (in 1 V steps) |
Rated Testing Current | 1 mA, Short-circuit current: 200 mA or less | |
Measurement Range/Accuracy | 0.10 to 9999 MΩ, 4 ranges, ± 4 % rdg. (representative values for 0.5 MΩ to 1,000 MΩ) | |
Timer | Setting Range | 0.3 to 999 s, Ramp/delay: Testing voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s |
Included Accessories | H.V. Test Lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Spare fuse ×1 |
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Hioki 3153 Automatic Insulation Hitester
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
Kyoritsu KEW 3552 Digital Insulation / Continuity Tester
Rated 5.00 out of 5
In stock
Kyoritsu Kew 3022A
Rated 5.00 out of 5
In stock
Brenda –