Hioki BT3554-50 Battery Tester
The Hioki BT3554-50 ensures high-accuracy battery diagnostics for optimal performance checks. Perfect for professionals seeking reliable results.
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Buy Hioki Battery Tester BT3554-50
The Hioki BT3554-50 battery tester is essential for maintaining UPS and storage batteries, vital to any business’s operation. The Hioki BT3554-50 battery internal resistance tester sets the benchmark for evaluating the deterioration and remaining lifespan of UPS and other lead-acid batteries, offering a comprehensive diagnosis through battery resistance testing. The L2020 Pin Type Lead, specifically designed for this purpose, enhances testing efficiency with its L-shaped tip, allowing you to reach deep into battery racks to probe the terminals thoroughly.
The Hioki BT3554-50 battery tester sets a new standard for UPS and lead-acid diagnostics. Since the internal resistance and voltage of the battery are measured using the impedance method, the diagnosis can be performed while the BT3554-50 is connected to its host device without disconnecting it. The patented noise reduction technology enables a more accurate measurement, even in noisy environments.
Hioki Battery Tester BT3554-50 specifications
Hioki Battery Tester BT3554-50 measures in four ranges: 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ).
| BT3554-50 | |
| Resistance measurement range | 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges |
| Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt) | |
| Testing source frequency: 1 kHz ±30 Hz | |
| With function for avoiding noise frequency enabled: 1 kHz ±80 Hz | |
| Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) | |
| Open terminal Voltage: 5 V peak | |
| Voltage measurement range | ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt |
| Temperature measurement accuracy | Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F) |
| * When using the Clip Type Lead with Temperature Sensor 9460. | |
| * When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1″]). | |
| * When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94″]). | |
| Hioki BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F) | |
| Absolute max. input voltage | 60 V DC max. (No AC input) |
| Measurement time | 100 ms |
| Response time | Approx. 1.6 sec. |
| Comparator | Compares measured values with set threshold values to make judgments and reports them to the user. |
| Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound | |
| When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL | |
| When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL | |
| If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight. | |
| User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment ) | |
| Savable settings: 200 tables | |
| Memory functionality | Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units) |
| Saved data: Saved measurement data is linked to profile information. | |
| 1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument. | |
| -1. Date and time | |
| -2. Resistance value, voltage value, and temperature | |
| -3. Comparator threshold value and judgment result | |
| 2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One). | |
| -1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number) | |
| -2. Location: User-defined comment such as location of UPS | |
| -3. Device information: User-defined comment such as UPS management number | |
| -4. Battery number: 1 to 500 (start number, end number) | |
| Measurement Navigator | Operation: Announces the next battery number to be measured via a screen display and audio guidance. |
| When using the Z3210 and a supported application (GENNECT Cross), audio output is generated by a connected mobile device. | |
| Preparations: Profile information that’s been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument. | |
| Communication interface | USB |
| Bluetooth® wireless communications (when Z3210 installed) | |
| Other functions | Temperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock |
| Power supply | LR6 (size AA) alkaline battery ×8 |
| Rated supply voltage: 1.5 V DC × 8 | |
| (Nickel metal hydride batteries may be used. However, the battery life display is not supported in this configuration.) | |
| Continuous operating time: Approx. 8.3 hr. (without Z3210 installed), Approx. 8.2 hr. (with Z3210 installed and wireless communications active) | |
| Dimensions and mass | 199 mm (7.83 in)W × 132 mm (5.20 in)H × 60.6 mm (2.39 in)D (with protector), 960 g (33.9 oz) (including batteries and protector) |
| Included accessories | Carrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, Application software CD (GENNECT One) ×1, AA alkaline battery (LR6) ×8, User Manual ×1 |
| Instrument only |
Buy the Hioki BT3554-50 battery tester, a must-have tool for businesses to ensure the optimal performance and longevity of their UPS and lead-acid batteries.
Specifications
Technical Specifications
| Resistance Measurement Range | 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges |
|---|---|
| Accuracy | ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt) |
| Testing Source Frequency | 1 kHz ±30 Hz With function for avoiding noise frequency enabled: 1 kHz ±80 Hz |
| Testing Current | 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) |
| Open Terminal Voltage | 5 V peak |
| Voltage Measurement Range | ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt |
| Temperature Measurement Accuracy | Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F) |
| Response Time | Approx. 1.6 sec. |
| Measurement Time | 100 ms |