The Megger AVO215 True-RMS Digital Multimeter delivers accurate AC/DC measurements up to 600 V and 10 A, with CAT III 600 V safety, 4000-count backlit LCD, and rugged housing. Suits electricians, HVAC and industrial technicians.

  • Secure Purchase
  • Fast Delivery
  • Genuine Guarantee
  • Online Payment

Specifications

Megger AVO215 True-RMS Digital Multimeter Specifications

PARAMETER SPECIFICATION
Display 4000 counts, backlit high-contrast negative LCD
DC voltage 400 mV to 600 V; ±(1.0% rdg + 3–5 dgt)
AC voltage (True RMS) 4 V to 600 V; ±(1.2% rdg + 3 dgt)
DC current 400 µA to 10 A (20 A for 30 s max); ±(1.0–1.2% rdg + 3 dgt)
AC current (True RMS) 400 µA to 10 A (20 A for 30 s max); ±(1.2–1.8% rdg + 3–5 dgt)
Resistance 0 to 40 MΩ; ±(1.5–2.5% rdg + 5–20 dgt)
Capacitance 0 to 4000 µF; ±(3.0–5% rdg + 5–10 dgt)
Frequency 10 Hz to 10 kHz; ±(1.2% rdg)
Duty cycle 0.1 to 99.9%; ±(1.2% rdg + 2 dgt)
Continuity Audible buzzer if resistance < 50 Ω (approx.); test current < 0.35 mA
Diode test Test current 1.5 mA max; open-circuit voltage ~3 V DC
Functions True RMS, Data Hold, MAX/MIN, built-in flashlight, auto/manual range
Safety rating CAT III 600 V
Battery 2 × 1.5 V AAA
Dimensions 182 × 82 × 59 mm
Weight 342 g (0.753 lb)
Input impedance >10 MΩ VDC / VAC
ACV bandwidth 50/60 Hz (all waveforms); 45 Hz to 1000 Hz (sine wave)
Crest factor ≤3 at full scale up to 300 V, decreasing linearly to ≤1.5 at 600 V
Frequency sensitivity 15 V rms
Duty cycle pulse width 100 µs to 100 ms, 5 Hz to 150 kHz
Overrange indication ‘OL’ displayed
Polarity Automatic, minus symbol for negative
Measurement rate 3 times per second
Fuses mA/µA: 0.5 A 600 V ceramic quick blow; A: 10 A 600 V ceramic quick blow
Operating temperature 5 °C to 40 °C (41 °F to 104 °F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F)
Operating humidity Max 80% up to 31 °C, decreasing linearly to 50% at 40 °C
Storage humidity <80%
Operating altitude ≤2000 m (7000 feet)
Drop test 2 metres (6.5 feet)
Accuracy reference 18 °C to 28 °C (65 °F to 83 °F), less than 75% RH

Megger AVO215 range-by-range accuracy

DC Voltage

Range Resolution Accuracy
400 mV 0.1 mV ± (1.0% reading + 5 digits)
4 V 0.001 V ± (1.0% reading + 3 digits)
40 V 0.01 V
400 V 0.1 V
600 V 1 V

AC Voltage

Range Resolution Accuracy
4 V 0.001 V 50/60 Hz: ± (1.2% reading + 3 digits)
40 V 0.01 V
400 V 0.1 V
600 V 1 V

All AC voltage ranges specified from 5% to 100% of range.

DC Current

Range Resolution Accuracy
400 µA 0.1 µA ± (1.0% reading + 3 digits)
4000 µA 1 µA ± (1.2% reading + 3 digits)
40 mA 0.01 mA
400 mA 0.1 mA
4 A 0.001 A
10 A 0.01 A

(20 A: 30 seconds maximum with reduced accuracy)

AC Current

Range Resolution Accuracy
400 µA 0.1 µA ± (1.2% reading + 3 digits)
4000 µA 1 µA
40 mA 0.01 mA
400 mA 0.1 mA
4 A 0.001 A ± (1.8% reading + 5 digits)
10 A 0.01 A

(20 A: 30 seconds maximum with reduced accuracy)
All AC current ranges specified from 5% to 100% of range.

Resistance

Range Resolution Accuracy
400 Ω 0.1 Ω ± (1.5% reading + 5 digits)
4 kΩ 0.001 kΩ
40 kΩ 0.01 kΩ
400 kΩ 0.1 kΩ
4 MΩ 0.001 MΩ
40 MΩ 0.01 MΩ ± (2.5% reading + 20 digits)

Capacitance

Range Resolution Accuracy
40 nF 0.01 nF ± (4.5% reading + 10 digits)
400 nF 0.1 nF
4 µF 0.001 µF ± (3.0% reading + 5 digits)
40 µF 0.01 µF
400 µF 0.1 µF
4000 µF 1 µF ± (5% reading + 5 digits)

Frequency

Range Resolution Accuracy
10 Hz – 10 kHz 0.01 Hz ± (1.2% reading)

Sensitivity: 15 V rms

Duty Cycle

Range Resolution Accuracy
0.1 to 99.9 % 0.1 % ± (1.2% reading + 2 digits)

Pulse width: 100 µs – 100 ms, Frequency: 5 Hz to 150 kHz