Megger DLRO10X with DH4-C Lead Set - Kit
The Megger DLRO10X is a 10 A digital low resistance ohmmeter measuring 0.1 µΩ to 2000 Ω, with colour display, 700-test memory and RS232, bundled here with the DH4-C duplex handspike lead set.
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
Buy the Megger DLRO10X with DH4-C Lead Set – Kit in the UAE from MME, an authorized Megger representative in Dubai. See the full Megger range on our Megger brand page.
Megger DLRO10X Extended Field Kit with DH4-C Duplex Handspikes
The Megger DLRO10X with DH4-C Lead Set is a complete, ready-to-deploy diagnostic kit tailored for electrical commissioning engineers and field service technicians. Combining the proven Megger DLRO10X 10A micro-ohmmeter with the heavy-duty DH4-C duplex handspike lead set, this turnkey package simplifies single-operator contact resistance testing across complex busbar and panelboard layouts.
Why Choose the Megger DLRO10X DH4-C Extended Field Kit?
What the DH4-C handspikes add to a DLRO10X:
- Integrated Status Indicator Lights: The DH4-C handspikes feature built-in LEDs that display live test status, pass/fail results, and continuity directly at your fingertips—eliminating the need to look back at the base unit screen during measurements.
- Spring-Loaded Duplex Contact Pins: Dual-action Kelvin pins ensure solid mechanical contact on uneven, coated, or oxidized busbar surfaces.
- Single-Operator Efficiency: Streamlined cable management (1.5 m duplex leads, 48 mΩ total loop resistance) prevents tangles in tight switchgear compartments and enables rapid point-to-point probing.
- Complete Turnkey Package: Supplied fully equipped with the DLRO10X instrument, DH4-C lead set, rechargeable lithium-ion battery module (6121-492) and battery charger (6280-333).
Recommended Use Cases for the Megger DLRO10X DH4-C Kit
Where the DLRO10X with DH4-C kit earns its place:
- Fast-paced production line testing of circuit breakers, contactors, and knife switches.
- Substation maintenance routines where visual pass/fail confirmation right on the handspike speeds up workflow.
- Confined space panelboard and switchboard testing where two-hand operation requires immediate feedback.
Who the Megger DLRO10X with DH4-C kit is for
This kit, Megger order code 1006-600, is for commissioning and maintenance engineers who test busbar joints, breaker contacts, battery straps and bonds on their own. The DLRO10X picks the test current itself, up to 10 A DC, and measures from 0.1 µΩ to 2000 Ω on seven ranges. It applies forward and reverse current and shows both readings and their average within about 3 seconds, which cancels standing EMFs. Auto mode suits the handspikes: each time all four probes touch the joint a new test runs without pressing the button, and the current and potential connections are checked for continuity first. Unidirectional mode (DLRO10X only) speeds up battery-strap work, and inductive mode waits for a winding to settle. On the lit handspike, lamp L1 shows red for poor contact at the C or P tips, and lamp L2 turns green when the current has fallen below 1 mA and the test is complete; with pass bands set on the DLRO10X, L2 shows green for pass and red for fail. Megger does not recommend handspikes for inductive loads; use clip leads there.
Megger’s datasheet figures: accuracy is ±0.2% ±0.2 µΩ on the 1.9999 mΩ range at 10 A, and and ±0.2% plus a few digits on every rangeplusmn;0.2% plus a fixed offset on every range. Test current accuracy is ±10%, and total lead resistance can be up to 100 mΩ at 10 A. A warning shows if 50/60 Hz noise above 100 mV peak is on the potential leads. Up to 700 results are stored with notes of up to 200 characters typed on the keypad, and results go to a PC over RS232 in real time or later. The lithium-ion battery module has its own charge indicator, gives about 1300 tests at 10 A and charges to 90% in 2.5 hours (full in 4 hours) from mains or a 12 to 15 V DC supply. The optional DLRO10LPU replaces the battery pack to run it from 90 to 264 V mains on a production line. Full accuracy runs from +5 to +45 °C. The case is IP65 closed and IP54 on battery, 220 × 100 × 237 mm, 2.6 kg with battery. Megger’s CAT III 600 V rating applies only with DH6 leads; with the DH4-C the instrument is still protected to 600 V.
Typical jobs from Megger’s list: switch and breaker contacts, busbar and cable joints, aircraft frame bonds, welded joints, inter-cell connections on battery systems up to 600 V peak, transformer and motor windings, and rail and pipe bonds.
MME is an authorized Megger representative in the UAE. See our micro-ohmmeters. For the instrument on its own page, see the Megger DLRO10X; for the LED-display model, see the Megger DLRO10 or the DLRO10-NLS. For spare handspikes, see the Megger DH4-C, and for other terminations the Megger DLRO 10 A duplex test lead system. For a rugged lid-open IP65 unit, see the Megger DLRO10HD; for 100 A on breakers, the Megger DLRO100X. Read our Megger DLRO10X review.
What’s in the Megger DLRO10X DH4-C box
What comes in the kit (1006-600):
- Megger DLRO10X digital low resistance ohmmeter
- DH4-C duplex handspike lead set
- Lithium-ion rechargeable battery and charger
- User guide (the carrying case, 6380-138, is an optional extra)
Megger DLRO10X vs DLRO10
The DLRO10X adds a colour display, menu-driven control, 700-record storage, 200-character memos, RS232 download, forward/reverse/average display and user pass/fail limits. The Megger DLRO10 is the simpler LED-display model without on-board storage.
Megger DLRO10X with DH4-C kit questions
What engineers ask before ordering:
- Is this the DLRO10X itself? Yes. It is the DLRO10X supplied with DH4-C handspikes (1006-600). The DLRO10X-NLS (1006-659) has no leads.
- Can it run from mains? Yes, with the optional DLRO10LPU fitted in place of the battery pack.
- How many 10 A tests per charge? About 1300, according to Megger.
Base Instrument Specifications & Custom Configurations
This package is built around the industry-standard
Megger DLRO10X Digital Low Resistance Ohmmeter
. If you only need the standalone unit, already have compatible Kelvin test leads, or wish to configure custom clamp and probe accessories (such as 5.5m extended leads or heavy-duty C-clamps), please visit the primary product page.
Specifications
Specifications
Megger DLRO10X Specifications
| Parameter | Specification |
| Resistance range | 0.1 µΩ to 2000 Ω (seven ranges) |
| Best resolution | 0.1 µΩ |
| Accuracy | ±0.2% |
| Maximum test current | 10 A d.c. |
| Measurement speed | 3 seconds (forward + reverse, average) |
| Test modes | Normal, Auto, Continuous, Inductive, unidirectional |
| Display | Large colour: forward, reverse, average; pass/fail limits |
| Memory | 700 tests, 200-character memos |
| Interface | RS232 (real-time / delayed download) |
| Leads | Duplex Kelvin system; DH4-C handspikes included |
| Power | Lithium-ion rechargeable (~1300 × 10 A tests); optional mains 90–264 V |
| Operating temperature | +5 °C to +45 °C (full accuracy) |
| Ingress protection | IP65 case closed, IP54 in operation |
| Dimensions | 220 × 100 × 237 mm |
| Weight | 2.6 kg (with battery) |
| Measurement mode | Manual, Auto, Continuous, Inductive, Undirectional |
| Measurement control | Fully Automatic / Manual |
| Test method | Single cycle reversing DC ratiometric measurement – average result display |
| Voltmeter input impedance | >200 kΩ |
| Noise rejection | <1% ±20 digits additional error with 100 mV peak 50/60 Hz on potential leads. Warning shown if exceeded |
| Data transfer | Real time or from storage via RS232 |
| Data storage | 700 tests |
| Memo field | Up to 200 characters per test via integral alphanumeric keypad |
| Battery type | 5.2 Ah lithium-ion rechargeable |
| Battery life | Typical 1300 × 10 A tests before recharge |
| Battery charge time | External 90–260 V 50/60 Hz charger from 12–15 V DC. Standard: 2.5 h to 90%, 4 h full. Slow charge: +10 °C to +45 °C |
| Operating temperature & humidity | +5 °C to +45 °C (41 °F to 113 °F) at full accuracy -10 °C to +50 °C (14 °F to 122 °F) reduced accuracy <90% RH @ 40 °C non-condensing |
| Temperature coefficient | <0.01% per °C (5 °C–40 °C) / <0.0006% per °F (41 °F–104 °F) |
| Maximum altitude | 2000 m (6562 ft) to full safety specifications |
| Safety | IEC61010-1, CAT III 600 V (only when DH6 leads used) |
| EMC | IP65 case closed, IP54 battery operation (IEC61326-1 Heavy industrial) |
| Note | Accuracy assumes forward and reverse measurements. Inductive or undirectional mode may introduce error if external EMF is present. |
Datasheet