Megger DLRO10X with DH4-C Lead Set - Kit

Brand: Megger
SKU: 125680
Order code: 1006-600
Share

The Megger DLRO10X is a 10 A digital low resistance ohmmeter measuring 0.1 µΩ to 2000 Ω, with colour display, 700-test memory and RS232, bundled here with the DH4-C duplex handspike lead set.

  • Secure Purchase
  • Fast Delivery
  • Genuine Guarantee
  • Online Payment

Specifications

Megger DLRO10X Specifications

Parameter Specification
Resistance range 0.1 µΩ to 2000 Ω (seven ranges)
Best resolution 0.1 µΩ
Accuracy ±0.2%
Maximum test current 10 A d.c.
Measurement speed 3 seconds (forward + reverse, average)
Test modes Normal, Auto, Continuous, Inductive, unidirectional
Display Large colour: forward, reverse, average; pass/fail limits
Memory 700 tests, 200-character memos
Interface RS232 (real-time / delayed download)
Leads Duplex Kelvin system; DH4-C handspikes included
Power Lithium-ion rechargeable (~1300 × 10 A tests); optional mains 90–264 V
Operating temperature +5 °C to +45 °C (full accuracy)
Ingress protection IP65 case closed, IP54 in operation
Dimensions 220 × 100 × 237 mm
Weight 2.6 kg (with battery)
Measurement mode Manual, Auto, Continuous, Inductive, Undirectional
Measurement control Fully Automatic / Manual
Test method Single cycle reversing DC ratiometric measurement – average result display
Voltmeter input impedance >200 kΩ
Noise rejection <1% ±20 digits additional error with 100 mV peak 50/60 Hz on potential leads. Warning shown if exceeded
Data transfer Real time or from storage via RS232
Data storage 700 tests
Memo field Up to 200 characters per test via integral alphanumeric keypad
Battery type 5.2 Ah lithium-ion rechargeable
Battery life Typical 1300 × 10 A tests before recharge
Battery charge time External 90–260 V 50/60 Hz charger from 12–15 V DC. Standard: 2.5 h to 90%, 4 h full. Slow charge: +10 °C to +45 °C
Operating temperature & humidity +5 °C to +45 °C (41 °F to 113 °F) at full accuracy -10 °C to +50 °C (14 °F to 122 °F) reduced accuracy <90% RH @ 40 °C non-condensing
Temperature coefficient <0.01% per °C (5 °C–40 °C) / <0.0006% per °F (41 °F–104 °F)
Maximum altitude 2000 m (6562 ft) to full safety specifications
Safety IEC61010-1, CAT III 600 V (only when DH6 leads used)
EMC IP65 case closed, IP54 battery operation (IEC61326-1 Heavy industrial)
Note Accuracy assumes forward and reverse measurements. Inductive or undirectional mode may introduce error if external EMF is present.

Download the Megger DLRO10 / DLRO10X datasheet (PDF)PDF