Megger STX40 Portable Fault Location System
Short Description:
Megger STX40 Portable fault location system
- True portable outdoor-ready unit, IP 43
- Very easy to use “turn&click” single rotary knob interface
- Surge/Thump energy 2,000 Joule
- DC testing up to 40 kV, surging/thumping up to 32 kV, burning up to 40 kV
- Prelocation methods: Inductive ARM with Multishot, ICE and DECAY
- Built-in safety circuits for earth connection monitoring (F-Ohm) and touch potential monitoring (F-Voltage)
- Full TDR control of all HV functions
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
13
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Megger STX40 Portable fault location system
The Megger STX40 Portable fault location system is the most powerful and modern portable fault location system on the market. It is ideally suited for proof testing, analyzing, relocating, and pinpointing faults on extruded low-voltage and medium-voltage XLPE- and EPR-insulated cables. With its 40 kV DC source and a potent high-frequency burner, it is also competent and effective on PILC cables as well.
The Megger STX40 Portable fault location system is fully automatic with motorized HT switches controlled by a knob or industrial-grade color touchscreen. To get information about megger stx40 price and please get in touch with us.
STX40 portable cable fault Features
- True portable outdoor-ready unit, IP 43
- Very easy to use “turn&click” single rotary knob interface
- Surge/Thump energy 2,000 Joule
- DC testing up to 40 kV, surging/thumping up to 32 kV, burning up to 40 kV
- Prelocation methods: Inductive ARM with Multishot, ICE, and DECAY
- Built-in safety circuits for earth connection monitoring (F-Ohm) and touch potential monitoring (F-Voltage)
- Full TDR control of all HV functions
Megger STX40 Portable Fault Location System Specifications
- Protection class IP 43, weather-resistant and rainproof
- Weight 119 kg (262 lbs) standard version 124 kg (273 lbs) extended version
- Insulation test Voltage ranges of 5/10/15/20 kV
- Measuring range of 650 MΩ HV Source 0 … 40 kV DC test (DC hi-pot) 50 mA nominal continuous current
- Breakdown detection 0 … 40 kV
- Burning High-frequency burner
max 850 mA in 5 kV range
max 400 mA in 10 kV range
max 200 mA in 20 kV range
max 100 mA in 40 kV range - Standard surge levels 0 … 8 / 0 … 16 / 0 … 32 kV
2,000 / 2,000 / 2,000 J - Additional surge levels Optionally 4 kV with 1,100 J
- Surge rate Adjustable 3 … 10 sec, and single shot;
3 seconds at the full output of 32kV - Sheath testing and : 3 kV, 5 kV, 10 kV, and 20 kV
- Sheath fault pinpointing: Pulse sequences of 0.5:1, 1:3, 1:4, 1:6
- Built-in location: 32 kV inductive ARM Best Picture Multishot
32 kV ICE
40 kV DECAY
IFL mode - Operating temperature : -20°C … +55°C (-4°F … +131°F)
- Storage temperature : -40°C … +70°C (-40°F … +158°F)
- Mains input supply: 2.5 kW wide range power source 110 … 230 V AC, 50/60 Hz Limited to 1.6 kW at 120 V AC (as per ANSI/NEMA 5)
- Dimensions (L x W x H) : 710 x 740 x 1,080 mm (27.9 x 29.1 x 42.5 in.
To get information about Megger stx40-2000 price and buy this product contact us through mme.
ACCESSORIES
- digiPHONE+2 set
- digiPHONE+2 NT set
- digiPHONE+2 NTRX set
Specifications
Specification | Details |
---|---|
Protection class | IP 43, weather-resistant and rainproof |
Weight | 119 kg (262 lbs) standard version, 124 kg (273 lbs) extended version |
Insulation test | Voltage ranges of 5/10/15/20 kV |
Measuring range | 650 MΩ HV Source 0 … 40 kV DC test (DC hi-pot) 50 mA nominal continuous current |
Breakdown detection | 0 … 40 kV |
Burning | High-frequency burner, max 850 mA in 5 kV range, max 400 mA in 10 kV range, max 200 mA in 20 kV range, max 100 mA in 40 kV range |
Standard surge levels | 0 … 8 / 0 … 16 / 0 … 32 kV, 2,000 / 2,000 / 2,000 J |
Additional surge levels | Optionally 4 kV with 1,100 J |
Surge rate | Adjustable 3 … 10 sec, and single shot; 3 seconds at the full output of 32kV |
Sheath testing | 3 kV, 5 kV, 10 kV, 20 kV |
Sheath fault pinpointing | Pulse sequences of 0.5:1, 1:3, 1:4, 1:6 |
Built-in location | 32 kV inductive ARM Best Picture Multishot, 32 kV ICE, 40 kV DECAY, IFL mode |
Operating temperature | -20°C … +55°C (-4°F … +131°F) |
Storage temperature | -40°C … +70°C (-40°F … +158°F) |
Mains input supply | 2.5 kW wide range power source 110 … 230 V AC, 50/60 Hz Limited to 1.6 kW at 120 V AC (as per ANSI/NEMA 5) |
Dimensions (L x W x H) | 710 x 740 x 1,080 mm (27.9 x 29.1 x 42.5 in.) |
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Megger STX40 Portable Fault Location System
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Deborah –
Send in a timely manner