Megger TRAX 220 Transformer and Substation Test System

Brand: Megger
SKU: 125692
Share

The Megger TRAX 220 is a multifunction transformer and substation test system with a built-in 10.4-inch touchscreen, combining winding resistance, turns ratio, tan delta/power factor, excitation current, leakage reactance and demagnetization in a single 200 A instrument.

  • Safe Buy
  • Fast Delivery
  • Original Guarantee
  • Online Payment

Specifications

Specification Details
Conditions Specifications valid at nominal input voltage and +23°C ±5°. Subject to change without notice.
Environment
Application field For use in high-voltage substations and industrial environments
Temperature Operating: –20°C to +55°C (–4°F to +131°F)
Storage: –20°C to +70°C (–4°F to +158°F)
Humidity <90% RH, non-condensing
CE-marking LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EU
Classifications and standards
IP rating (IEC 60529) Instrument only: IP20
Instrument in hard case: IP21
General
Mains input 100–240 V, 50/60 Hz (±10%)
Input current ≤16 A continuous, up to 30 A short-term (<60 s)
Main fuses F1 and F2, 25 A
Ground connections TEST GROUND: Connect to object ground first
GROUND: For extra grounding to unit or external objects
Dimensions Instrument: 475 × 315 × 330 mm (18.7” × 12.4” × 13”)
Soft case: 690 × 450 × 390 mm (27” × 18” × 15”)
Hard case: 690 × 410 × 450 mm (27” × 16” × 18”)
Weight TRAX 219: 25 kg (55 lbs) / 29 kg (64 lbs) / 37 kg (82 lbs)
TRAX 220: 26 kg (57 lbs) / 30 kg (66 lbs) / 38 kg (84 lbs)
TRAX 279: 29 kg (64 lbs) / 33 kg (73 lbs) / 41 kg (90 lbs)
TRAX 280: 30 kg (66 lbs) / 34 kg (75 lbs) / 42 kg (93 lbs)
Display Size: 10.4”
Resolution: 1024 × 768 XGA
Type: TFT touch
Contrast ratio: 1000:1
Brightness: 1000 cd/m²
* TRAX 219 and 279 have no display
Outputs
0–2200 VAC 1 A (1 min), 0.2 A (>2 h), 2500 VA max, 5–70 Hz
0–250 VAC / 0–10 AAC 10 A (1 min), 20 A (10 s max), 2.5 A (>2 h), 5–505 Hz
0–200 AAC 200 A/6 V (1 min), 80 A (>2 h), 45–70 Hz
TRAX 219/220: 0–800 AAC 800 A/6 V (1 min), 200 A/10 V (>2 h), 45–70 Hz
TRAX 279/280: 0–800 AAC 0–800 A/6 V (1 min), 0–200 A/10 V (>2 h), 45–70 Hz
0–16 ADC 16 A continuous, 1 A continuous
0–300 VDC 10 A (1 min), 2.5 A (>2 h), rectified DC, auxiliary supply
0–100 ADC 100 A (2 min), 70 A continuous
DC output power Max 1000 VA continuous, Max 50 V compliance voltage
Binary output 250 V / 35 A max, 2 × 0–10000 s, for OLTC/circuit breaker operation
AUX CONTROL 54 V DC Ethernet comms and power for accessories
POWER 0–235 V AC direct, for powering accessories (TDX/TCX)
With TDX 120 12 kV AC, 500 mA (30 s), 300 mA (4 min), 200 mA (30 min), 100 mA continuous
With TCX 200 2000 A AC, 0–2000 A/2.4 V (1 min), 0–1000 A/4.8 V (1 min)
Inputs
ANALOG 1–4 Current: 4 × 0–10 A AC/DC
Voltage: 4 × 250/300 V AC/DC
R1 R2 2 × 0–50 V DC, intended for resistance measurement, usable up to 40 V RMS
TRANS Analog transducers and low-level analog signals
TRIG IN Contact or voltage sense
TIMING 3 × 0–10000 s, binary inputs for timing in relay/circuit breaker testing
Calculated / Displayed Parameters
Arithmetic +, –, ×, ÷
Power P, VA, Q, S
Impedance R (DC), Z, Xp, Xs, Rs, Rp, Ls, Lp, Cs, Cp, phase
Derating Conditions
Lower mains voltage Output power decreased below 230–240 V
High ambient temperature Reduced output current times at higher ambient
Lower frequencies Voltage output derates linearly; at 5 Hz, max 10% of rated output
Measurement Accuracy
External AC/DC voltage & current 0.05% rdg + 0.05% FS (I ≤5 A)
0.2% rdg + 0.2% FS (5<I ≤10 A)
Internal DC current 0.1% rdg + 0.1% FS
Internal AC current 0.2% rdg + 0.2% FS
Internal AC voltage 0.2% rdg + 0.2% FS
Phase (0–360°) 0.1°
Accuracy (Derived Parameters)
WRM 1 A generator: 10 mΩ–10 kΩ
16 A generator: 0.63 mΩ–33.3 Ω
100 A generator: 0.1 mΩ–2.5 Ω
Accuracy: 0.15% rdg + 0.15% FS, up to 4 digits
TTR 2500:1–1:25 000, Accuracy 0.07%, up to 4 digits
Communication
Ethernet For external PC control or network connection
USB 3 × USB ports for multipurpose use
0 reviews
0
0
0
0
0

There are no reviews yet.