Fluke 381 Remote Display TRMS Clamp Meter
- True RMS AC/DC current measurement up to 999.9 A
- Remote display with flexible current probe for hard-to-reach conductors
- Jaw opening 34 mm with position sensitivity markers A, B, C
- Wireless connectivity via 2.4 GHz ISM band for safe distance measurements
- AC voltage range 600 V / 1000 V with 1.5% accuracy
- TRMS measurement for accurate readings on non-linear loads
- Safety compliance CAT III 1000V / CAT IV 600V
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 381 Remote Display TRMS Clamp Meter sets a new standard for electrical measurement safety and convenience. Designed for professional electricians and engineers, this instrument allows users to measure current in conductors without making direct contact, reducing risk in energized panels. The remote display unit, connected by a flexible current probe, enables safe measurement in confined spaces or around hazardous live parts. With True RMS capability, the Fluke 381 provides accurate readings on both linear and non-linear electrical loads, making it an essential tool for troubleshooting, maintenance, and installation work across industrial and commercial environments.
Fluke 381 Key Features
The Fluke 381 combines advanced True RMS technology with a remote display system that enhances both safety and measurement accuracy. The flexible current probe extends the measurement capability to conductors that are otherwise inaccessible, while the main unit displays readings wirelessly via the 2.4 GHz ISM band. Position sensitivity markers (A, B, C) on the jaw ensure optimal conductor placement for accurate readings, and the TRMS function guarantees precise measurements across various waveform types. This clamp meter is built to withstand demanding workshop environments while delivering the reliability Fluke is known for.
- AC Current via Jaw: 999.9 A range, 0.1 A resolution, 2% accuracy (10-100 Hz)
- AC Current via Flexible Probe: 999.9 A / 2500 A range, 0.1 A / 1 A resolution, 3% accuracy
- DC Current: 999.9 A range, 0.1 A resolution, 2% accuracy
- AC Voltage: 600 V / 1000 V range, 0.1 V / 1 V resolution, 1.5% accuracy
- DC Voltage: 600.0 V / 1000 V range, 0.1 V / 1 V resolution, 1% accuracy
- Frequency Measurement: 5.0 – 500.0 Hz range, 0.1 Hz resolution
- Resistance: 600 Ω / 6 kΩ / 60 kΩ ranges
- Safety: CAT III 1000V / CAT IV 600V with double insulation
Who Needs the Fluke 381?
Electrical maintenance technicians will find the Fluke 381 indispensable for troubleshooting live circuits without the need to disconnect conductors. The remote display feature allows safe measurement from a distance, which is critical when working on energized switchgear or distribution panels. Field engineers performing preventive maintenance will appreciate the flexibility of the current probe, enabling them to measure current in tight conduit spaces or around bundled wires where traditional clamp meters cannot reach. The wireless range of 10 meters provides additional safety by allowing operators to monitor readings from a protected position.
Industrial electricians working on motor controls and variable frequency drives benefit from the Fluke 381’s True RMS accuracy, ensuring proper load analysis on non-linear loads. Building services engineers can use the device for HVAC system commissioning and troubleshooting, while quality control inspectors rely on its precision for compliance testing. Even procurement teams specifying electrical test equipment will value the Fluke 381’s comprehensive specification set and industry-leading safety ratings, making it a sound investment for any organization’s tool inventory.
Fluke 381 Applications
The Fluke 381 excels in electrical panel troubleshooting, where technicians can clamp around bus bars from a safe distance using the remote display. This application is particularly valuable in industrial settings with high-voltage equipment where direct contact measurement poses significant risk. The flexible current probe further extends capabilities to measure current in bus duct systems, generator leads, and motor feeds without dismantling electrical enclosures.
Energy auditing and power quality analysis represent another key application for the Fluke 381. The True RMS measurement capability accurately captures harmonic distortion in modern electrical systems with variable frequency drives and LED lighting. Facility managers can use the device to identify inefficient circuits, while consulting engineers can verify power factor correction equipment performance. The frequency measurement function aids in diagnosing motor speed issues and detecting electrical faults in rotating equipment, making the Fluke 381 a versatile tool for both preventive and predictive maintenance programs.
Why Buy Fluke 381 from Mohammad Mahdi Electronics?
Mohammad Mahdi Electronics ensures every Fluke 381 Remote Display TRMS Clamp Meter comes with authentic manufacturer warranty and genuine calibration certificates. MME provides original products with full traceability and technical support that counterfeit suppliers cannot match. Our knowledgeable staff can assist with product selection, ensuring you receive the correct measurement tool for your specific application requirements.
When you purchase from mme-ae, you benefit from fast shipping across the UAE and comprehensive after-sales service. We stock the complete Fluke lineup including the 381 model, and our team understands the technical specifications that matter for your electrical measurement tasks. Choose Mohammad Mahdi Electronics for genuine Fluke products, competitive pricing structures for bulk orders, and the peace of mind that comes with buying from MME, MME of genuine Fluke instruments who stands behind every instrument they sell.
Fluke 381 Complete Specifications: Electrical specifications include AC current via jaw ranging from 999.9 A with 0.1 A resolution and 2% accuracy (10-100 Hz), extending to 5% accuracy (100-500 Hz). AC current via flexible probe covers 999.9 A / 2500 A range (45-500 Hz) with 3% accuracy. DC current measures up to 999.9 A with 0.1 A resolution and 2% accuracy. AC voltage ranges of 600 V / 1000 V provide 1.5% accuracy (20-500 Hz), while DC voltage ranges deliver 1% accuracy. Frequency measurement spans 5.0-500.0 Hz with 0.1 Hz resolution. Resistance ranges of 600 Ω / 6 kΩ / 60 kΩ offer 1% accuracy. Mechanical specifications show a unit size of 277 x 88 x 43 mm with the remote unit adding 55 mm, weighing 350 g total. Jaw opening measures 34 mm, with flexible current probe diameter of 7.5 mm and cable length of 1.8 m. Environmental operating temperature ranges from -10°C to +50°C, with storage capability from -40°C to +60°C. EMI/RF compliance follows EN 61326 standards and safety ratings include CAT III 1000V / CAT IV 600V with double insulation per IEC standards.
Start your Fluke 381 order today with Mohammad Mahdi Electronics and experience the difference that genuine quality and remote measurement capability can make for your electrical work. Our team is ready to assist with product inquiries and ensure you receive authentic Fluke instrumentation backed by full manufacturer support.
Fluke 381 Specifications
| Electrical Specifications | ||||
| AC Current via Jaw | ||||
| Range | 999.9 A | |||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) |
|||
| Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 |
|||
| AC Current via Flexible Current Probe | ||||
| Range | 999.9 A / 2500 A (45 Hz – 500 Hz) | |||
| Resolution | 0.1 A / 1 A | |||
| Accuracy | 3% ± 5 digits | |||
| Crest Factor (50/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
| Position Sensitivity | ||||
![]() |
Distance from Optimum | |||
| i2500-10 Flex | i2500-18 Flex | Error | ||
| A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ±0.5% | |
| B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ±1.0% | |
| C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ±2.0% | |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
| DC Current | ||||
| Range | 999.9 A | |||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits | |||
| AC Voltage | ||||
| Range | 600 V /1000 V | |||
| Resolution | 0.1 V / 1 V | |||
| Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
| DC Voltage | ||||
| Range | 600.0 V /1000 V | |||
| Resolution | 0.1 V / 1 V | |||
| Accuracy | 1% ± 5 digits | |||
| Frequency – Via Jaw | ||||
| Range | 5.0 – 500.0 Hz | |||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A |
|||
| Frequency via Flexible Current Probe | ||||
| Range | 5.0 to 500.0 Hz | |||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
|||
| Resistance | ||||
| Range | 600 Ω/6 kΩ/60 kΩ | |||
| Resolution | 0.1 Ω/1 Ω/10 Ω | |||
| Accuracy | 1% ± 5 digits | |||
| Mechanical Specifications | ||||
| Size (L x W x H) | 277 x 88 x 43 mm (55 mm for remote unit) | |||
| Weight | 350 g | |||
| Jaw Opening | 34 mm | |||
| Flexible Current Probe Diameter | 7.5 mm | |||
| Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
| Environmental Specifications | ||||
| Operating Temperature | -10°C to +50°C | |||
| Storage Temperature | -40°C to +60°C | |||
| Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) |
|||
| Operating Altitude | 2,000 meters | |||
| Storage Altitude | 12,000 meters | |||
| EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 |
|||
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||
| Wireless Frequency | 2.4 GHz ISM Band 10 meter range | |||
| Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. |
|||
| Double Insulation Clearance | Per IEC 61010-2-032 | |||
| Double Insulation Creepage | Per IEC 61010-1 | |||
| Agency Approvals | ||||
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.

Bench Multimeters
Reviews
Clear filtersThere are no reviews yet.