Description
Fluke 15B MAX: a dependable everyday multimeter
The Fluke 15B MAX is an economical digital multimeter for electricians, technicians, and maintenance staff who need dependable readings without paying for features they won’t use. It measures AC and DC voltage up to 1000 V, AC and DC current up to 10 A (including µA and mA ranges), resistance up to 40 MΩ, capacitance, and diode test. A misoperation alarm warns you when the leads are in the wrong input, and the supplied test leads have fine tips for tight terminals. Contractors in the UAE often hand the 15B MAX to apprentices and site crews: it covers routine checks on sockets, DBs, and control circuits, and it’s affordable to issue one per technician.
Compare it with other digital multimeters, and read our Fluke 15B technical review for real-world testing notes.
The Fluke 15B MAX is a reliable and accurate digital multimeter designed for various applications. With its new upgraded 15B+ model, this multimeter offers improved performance and added safety features.
Whether you’re a professional electrician or a DIY enthusiast, the Fluke 15B MAX is an excellent choice for your measurement needs. Its test leads with fine tips ensure precise measurements, and the misoperation alarm provides added safety.
Fluke 15B MAX Key Features
- AC/DC voltage: 600.0 mV to 1000 V (DC basic accuracy 0.5 % + 3)
- AC/DC current: 400.0 µA to 10.00 A (1.5 % + 3)
- Resistance: 400.0 Ω to 40.00 MΩ; capacitance: 40.00 nF to 2000 µF; diode test; continuity (70 Ω threshold)
- 6000-count backlit LCD; CAT III 600 V safety (IEC 61010-1); IP40
- Misoperation alarm for added safety
- Test leads with fine tips for precise measurements
- Press any key to wake up the multimeter
Fluke 15B MAX Applications
The Fluke 15B MAX is suitable for various applications, including electrical testing, maintenance, and troubleshooting.
Who Needs the Fluke 15B MAX?
The Fluke 15B MAX is ideal for professionals and DIY enthusiasts who require a reliable and accurate digital multimeter for their measurement needs.
Why Buy from MME?
Browse our multimeters. Read more in our how to choose the right meter. See other Fluke instruments.
At MME, we offer high-quality products, including the Fluke 15B MAX, at competitive prices. Our team of experts is always available to provide support and guidance to ensure that you find the right product for your needs.
Fluke 15B MAX Specifications
| Specifications | |||
|---|---|---|---|
| Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]). | |||
| Function | Range | Resolution | Accuracy (15B MAX) |
| AC Volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 |
| DC Volts | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 |
| DC Millivolts | 600.0 mV | 0.1 mV | 1.0 % + 10 |
| AC Current μA (40 Hz to 400 Hz)2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 |
| AC Current mA (40 Hz to 400 Hz)2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 |
| AC Current A (40 Hz to 400 Hz)2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
| DC Current μA2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 |
| DC Current mA2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 |
| DC Current A2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
| Diode Test3 | 2.000 V | 0.001 V | 10% |
| Resistance (Ohms)5 | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
| Capacitance6 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 2000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Continuity Threshold | — | — | 70Ω |
| Backlight | — | — | Yes |
| 1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A 3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA 5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA 6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). |
|||
Fluke 15B MAX General Specifications
| Display | 6000 counts, updates 3/sec, backlit |
| Safety rating | IEC 61010-1, IEC 61010-2-030: CAT III 600 V, Pollution Degree 2 |
| Max voltage between V and COM | 1000 V |
| Fuse protection | 440 mA, 1000 V fast-blow; 11 A, 1000 V fast-blow |
| Battery | 2 × AA (IEC LR6), 500 hours minimum |
| Operating temperature | 0 °C to 40 °C (storage -30 °C to 60 °C) |
| Size / weight | 183 × 91 × 49.5 mm / 455 g |
| Ingress protection | IP40 |
Fluke 15B MAX FAQ
What is the difference between the Fluke 15B MAX and the 17B MAX?
They share the same voltage, current, resistance and capacitance ranges. The 17B MAX adds temperature measurement (with a type-K thermocouple), frequency and duty cycle, and the 15B MAX doesn’t have these. If you only need electrical checks, the 15B MAX is the better-value choice. For model comparisons, see our Fluke 17B MAX page.
How does the 15B MAX improve on the 15B+?
Fluke describes the 15B MAX as continuing the 15B+ design. It adds an input alert alarm for leads in the wrong jack, wakes from sleep when you press any button, and comes with fine-tip test leads.
What is the safety rating of the Fluke 15B MAX?
It is rated CAT III 600 V to IEC 61010-1 and IEC 61010-2-030, which covers distribution boards and building wiring. For work at the service entrance, choose a CAT IV meter such as the Fluke 87V.
Can the 15B MAX measure capacitance and 10 A current?
Yes. It measures capacitance from 40.00 nF to 2000 µF and AC/DC current up to 10.00 A.
Which battery does it use?
It runs on 2 × AA (IEC LR6) batteries, rated for at least 500 hours.
Specifications
Specifications
| Specifications | ||||
|---|---|---|---|---|
| Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]). | ||||
| Function | Range | Resolution | Accuracy | |
| 15B MAX | 17B MAX | |||
| AC Volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 | 1.0 % + 3 |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | 3.0 % + 3 |
| DC Volts | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 | 0.5 % + 3 |
| DC Millivolts | 600.0 mV | 0.1 mV | 1.0 % + 10 | 1.0 % + 10 |
| AC Current μA (40 Hz to 400 Hz)2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| AC Current mA (40 Hz to 400 Hz)2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
| AC Current A (40 Hz to 400 Hz)2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
| DC Current μA2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| DC Current mA2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
| DC Current A2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
| Diode Test3 | 2.000 V | 0.001 V | 10% | 10% |
| Temperature 4 | 50.0 °C to 400.0 °C 0 °C to 50.0 °C -55.0 °C to 0 °C |
0.1 °C | NA | 2 %+1 °C 2 °C 9 %+2 °C |
| Resistance (Ohms)5 | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
| Capacitance6 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 2000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Frequency1 (10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA | 0.1 % + 3 |
| Duty Cycle1 | 1% to 99% | 0.10% | NA | 1 % typical7 |
| Continuity Threshold | — | — | 70Ω | 70Ω |
| Backlight | — | — | Yes | Yes |
| 1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A 3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA 4Use Type K thermocouple 5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA 6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 7 Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %. |
||||