Fluke 1623-2 KIT Basic Geo Earth Ground Tester, Kit
- 1999-digit LCD display with fluorescent backlight
- 1500-record internal memory accessible via USB
- IP56 rated, water and dust resistant design
- 3-pole and 4-pole ground resistance measurement modes
- Measuring range: 0.020 Ω to 19.99 kΩ
- Accuracy ±(2% rdg + 3 d) for 3-pole measurements
- 6 x 1.5V AA batteries with >3,000 measurement lifespan
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 1623-2 KIT Basic Geo Earth Ground Tester is a robust, handheld instrument designed for professionals who need to verify earth ground resistance in electrical systems. Featuring Fluke’s one-button TURN and START operation, this kit simplifies the testing process while delivering reliable measurements in tough industrial environments. Its IP56 rating ensures protection against dust and water ingress, making it suitable for outdoor use in various conditions.
Fluke 1623-2 KIT Key Features
This ground resistance tester combines advanced functionality with user-friendly operation. The device features a large 1999-digit LCD with fluorescent backlight for easy reading in any lighting condition, and internal memory storage for up to 1500 records that can be transferred via USB. The IP56-rated casing provides robust protection against environmental hazards, while the one-button concept with rotary switch ensures intuitive operation even for users wearing gloves. Additional features include automatic range selection, error monitoring for auxiliary earth electrodes, and compliance with international safety standards.
- 1999 digit LCD with fluorescent backlight
- Internal memory storage up to 1500 records accessible via USB port
- IP56 rated casing for water and dust resistance
- 3-pole and 4-pole ground resistance measurement modes
- Measuring range: 0.020 Ω to 19.99 kΩ
- Accuracy ±(2% rdg + 3 d) for 3-pole measurements
- 6 x 1.5V AA batteries with >3,000 measurement lifespan
- One-button TURN and START operation concept
Who Needs the Fluke 1623-2 KIT?
Electrical technicians and maintenance engineers responsible for grounding system testing will find the Fluke 1623-2 KIT indispensable for ensuring safety compliance and system reliability. The instrument’s versatile measurement capabilities make it suitable for both routine inspections and detailed fault analysis of grounding networks. Facility managers and safety officers responsible for occupational health and safety regulations will appreciate the instrument’s ability to quickly verify that grounding systems meet required standards, reducing the risk of electrical hazards in the workplace.
Contractors and field engineers working on substations, industrial plants, and commercial buildings will benefit from the Fluke 1623-2 KIT’s rugged construction and wide measuring range. The kit’s ability to perform both 3-pole and 4-pole measurements provides flexibility for different testing scenarios, from simple rod-to-rod measurements to complex ground grid analysis. The internal memory function allows for documentation of test results, essential for compliance reporting and trend analysis over time.
Electricity supply companies and consulting engineers specifying grounding systems will also find value in the Fluke 1623-2 KIT’s precision and reliability. The instrument’s compliance with IEC 1557-5 standards and adherence to DIN ISO 9001 quality systems ensures that measurements are consistent and trustworthy for specification verification and acceptance testing.
Fluke 1623-2 KIT Applications
The Fluke 1623-2 KIT is essential for testing and verifying grounding systems in substations and power distribution networks, where reliable earth resistance is critical for protecting equipment and personnel from fault currents. Utility companies use this kit during routine maintenance to monitor the condition of grounding electrodes and ensure continued compliance with safety regulations. The instrument’s wide measuring range accommodates everything from low-resistance ground rods to high-resistance soil conditions commonly found in industrial facilities.
In commercial and industrial buildings, the kit is used to verify that lightning protection systems and electrical grounding networks are functioning correctly. Maintenance teams rely on the Fluke 1623-2 KIT for periodic testing of generator grounding, transformer grounding, and building ground systems to prevent equipment damage from power surges and ensure personnel safety. The device is also valuable for testing ground fault currents in renewable energy installations, such as solar and wind farms, where proper grounding is essential for system performance and safety.
Why Buy Fluke 1623-2 KIT from mme-ae?
When you purchase the Fluke 1623-2 KIT from mme-ae, you are investing in genuine Fluke quality supported by Mohammad Mahdi Electronics’ commitment to customer satisfaction. Mme-ae ensures that every kit comes with full manufacturer warranty and certification, giving you peace of mind that you are receiving a genuine product built to the highest standards. Our knowledgeable team can provide technical assistance to help you select the right testing equipment for your specific application needs.
Mohammad Mahdi Electronics offers competitive pricing and fast delivery across the UAE, ensuring that your Fluke 1623-2 KIT arrives when you need it. We understand the importance of minimizing downtime for your operations, which is why we maintain stock of popular Fluke testing instruments and provide efficient shipping services. Our customer support team is available to answer technical questions and provide guidance on proper measurement techniques and interpretation of test results.
Technical specifications for the Fluke 1623-2 KIT include a measurement resolution ranging from 0.001 Ω to 10 Ω, with a measuring range extending from 0.020 Ω to 19.99 kΩ for 3-pole measurements. The instrument operates on 6 x 1.5V AA alkaline batteries, providing typical battery life of over 3,000 measurements. Physical dimensions measure 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 inches) and the unit weighs 1.1 kg (2.43 lb) including batteries, or 7.6 kg (16.8 lb) including all accessories and batteries in the carrying case. The device features a large 1999-digit LCD with fluorescent backlight, IP56-rated casing for environmental protection, and internal memory storage for up to 1500 test records accessible via USB interface.
Measurement capabilities include 3-pole ground resistance using the RA position with automatic range selection, and 4-pole ground resistance measurement for improved accuracy in complex grounding scenarios. The measuring principle employs current/voltage measurement with a 48V AC measuring voltage and a measurement frequency of 128 Hz. Short-circuit current exceeds 50 mA, and the instrument monitors auxiliary earth electrode resistance (RS) and (RH) with error indication to ensure measurement validity. Additional error from electrode resistances is calculated as RH[kΩ]•RS[kΩ]/RA[Ω]•••0.2%. Operating temperature range spans from -10°C to 50°C (14°F to 122°F), with storage capability from -30°C to 60°C (-22°F to 140°F). The climatic class is C1 (IEC 654-1) operating between -5°C to +45°C (23° to +115° F) at 5% to 95% RH, and the instrument provides protection by double and/or reinforced insulation with maximum 50V to earth per IEC61010-1 standards.
Safety features include EMC compliance per IEC61326-1 and protection according to pollution degree 2. External voltage rejection exceeds 120 dB at 16⅔, 50, 60, and 400 Hz, with maximum external voltage of 24V DC/AC < 400 Hz. Measurement is inhibited for values exceeding this threshold. The Fluke 1623-2 KIT is developed, designed, and manufactured according to DIN ISO 9001 quality system standards, ensuring consistent performance and reliability.
CTA: Choose Mohammad Mahdi Electronics for your Fluke 1623-2 KIT needs and experience reliable service from MME in the UAE.
Fluke 1623-2 KIT Specifications
| General Specifications | |
| Display: 1999 digit LCD | Display with special symbols, digit height 25 mm, fluorescent backlight |
| User interface | Instant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button |
| Robust, water and dust resistant | Instrument is designed for tough environmental conditions (rubber protective cover, IP56) |
| Memory | Internal memory storage up to 1500 records accessible via USB port |
| Temperature Range | |
| Operating temperature | -10°C to 50°C (14°F to 122°F) |
| Storage temperature | -30°C to 60°C (-22°F to 140°F) |
| Temperature coefficient | ±0.1% of reading/°C < 18°C > 28°C |
| Intrinsic error | Refers to the reference temperature range and is guaranteed for 1 year |
| Operating error | Refers to the operating temperature range and is guaranteed for 1 year |
| Climatic class | C1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH |
| Protective type | IP56 for case, IP40 for battery door according to EN60529 |
| Safety | Protection by double and/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2 |
| EMC (emission immunity) | IEC61326-1: Portable |
| Quality system | Developed, designed and manufactured according to DIN ISO 9001 |
| External voltage | V ext, max = 24 V (DC, AC < 400 Hz), measurement inhibited for higher values |
| V ext rejection | > 120 dB (162⁄3, 50, 60, 400 Hz) |
| Measuring time | Typical 6 seconds |
| Max. overload | 250 V rms (pertains to misuse) |
| Auxiliary power | 6 x 1.5 V Alkaline (type AA LR6) |
| Battery life span | Typical > 3,000 measurements |
| Dimensions (W x H x D) | 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in) |
| Weight | 1.1 kg (2.43 lb) including batteries 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case |
| RA 3-Pole Ground Resistance Measurement (IEC 1557-5) | |
| Switch position | RA 3-pole |
| Resolution | 0.001 Ω to 10 Ω |
| Measuring range | 0.020 Ω to 19.99 kΩ |
| Accuracy | ±(2% rdg + 3 d) |
| Operating error | ±(5% rdg + 3 d) |
| Measuring Principle: Current/Voltage Measurement | |
| Measuring voltage | Vm = 48 V AC |
| Short-circuit current | > 50 mA |
| Measure frequency | 128 Hz |
| Probe resistance (RS) | Max 100 kΩ |
| Auxiliary earth electrode resistance (RH) | Max 100 kΩ |
| Additional error from RH and RS | RH[kΩ]•••RS[kΩ]/RA[Ω]•••0.2% |
| Monitoring of RS and RH with error indicator. Automatic range selection. Measurement is not performed if the current through the current clamp is too low. |
|
| RA 4-Pole Ground Resistance Measurement (IEC 1557-5) | |
| Switch position | RA 4-pole |
| Resolution | 0.001 Ω to 10 Ω |
| Measuring range | 0.020 Ω to 19.99 kΩ |
| Accuracy | ±(2% rdg + 3 d) |
| Operating error | ±(5% rdg + 3 d) |
| Measuring Principle: Current/Voltage Measurement | |
| Measuring voltage | Vm = 48 V AC |
| Short-circuit current | > 50 mA |
| Measure frequency | 128 Hz |
| Probe resistance (RS + RES) | Max 100 kΩ |
| Auxiliary earth electrode resistance (RH) | Max 100 kΩ |
| Additional error from RH and RS | RH[kΩ]•••RS[kΩ]/RA[Ω]•••0.2% |
| Monitoring of RS and RH with error indicator. Automatic range selection. |
|
| RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp ) | |
| Switch position | RA 3-pole with clamp |
| Resolution | 0.001 Ω to 10 Ω |
| Measuring range | 0.020 Ω to 19.99 kΩ |
| Accuracy | ±(7% rdg + 3 d) |
| Operating error | ±(10% rdg + 5 d) |
| Measuring Principle: Current/Voltage Measurement (with External Current Clamp) | |
| Measuring voltage | Vm = 48 V AC |
| Short-circuit current | > 50 mA |
| Measure frequency | 128 Hz |
| Probe resistance (RS) | Max 100 kΩ |
| Auxiliary earth electrode resistance (RH) | Max 100 kΩ |
| Monitoring of RS and RH with error indicator. Automatic range selection. Measurement is not performed if the current through the current clamp is too low. |
|
| RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp ) | |
| Switch position | RA 4-pole with clamp |
| Resolution | 0.001 Ω to 10 Ω |
| Measuring range | 0.020 Ω to 19.99 kΩ |
| Accuracy | ±(7% rdg + 3 d) |
| Operating error | ±(10% rdg + 5 d) |
| Measuring Principle: Current/Voltage Measurement (with External Current Clamp) | |
| Measuring voltage | Vm = 48 V AC |
| Short-circuit current | > 50 mA |
| Measure frequency | 128 Hz |
| Probe resistance (RS) | Max 100 kΩ |
| Auxiliary earth electrode resistance (RH) | Max 100 kΩ |
| Monitoring of RS and RH with error indicator. Automatic range selection. Measurement is not performed if the current through the current clamp is too low. |
|
| Stakeless Ground Loop Measurement (2 Clamps) | |
| Switch position | RA 4-pole 2 clamps |
| Resolution | 0.001 Ω to 10 Ω |
| Measuring range | 0.020 Ω to 19.99 kΩ |
| Accuracy | ±(7% rdg + 3 d) |
| Operating error | ±(10% rdg + 5 d) |
| Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers | |
| Measuring voltage | Vm = 48 V AC |
| Measure frequency | 128 Hz |
| Noise current (IEXT) | Max. IEXT = 10 A (AC) (RA < 20 Ω) |
| Max. IEXT = 2 A (AC) (RA > 20 Ω) | |
| Automatic range selection. The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified. |
|
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)