Megger SMRT43D Multi-Phase Relay Test System

Brand: Megger
SKU: 5154
Share

The Megger SMRT43D is a three-phase relay test system with a built-in touchscreen controller. With up to three current and three voltage channels (32 A/phase, 135 A paralleled), variable frequency, COMTRADE transient playback and IEC 61850/GPS options, it tests modern protection schemes without an external PC.

  • Safe Buy
  • Fast Delivery
  • Original Guarantee
  • Online Payment

Specifications

Megger SMRT43D Multi-Phase Relay Test System – Technical Specifications
Input Power
Supply 90 to 264 Volts AC, 1Ø, 50/60 Hz, 1800 VA
Outputs
All outputs are independent from sudden changes in line voltage and frequency. Outputs are regulated, unaffected by load impedance. Each VIGEN module includes a voltage amplifier and current amplifier. Outputs are isolated or floating, with optional chassis ground return configuration.
Output Current Sources
Three current sources per SMRT43D (three VIGEN modules). Ratings are specified in AC RMS and peak power values.
Per Channel Output
Output Current Power / Max Voltage
1 A 15 VA / 15.0 V RMS
4 A 200 VA (282 peak) / 50.0 V RMS
15 A 200 VA (282 peak) / 13.4 V RMS
30 A 200 VA (282 peak) / 6.67 V RMS
45 A 300 VA (424 peak) / 6.67 V RMS
DC 30 A 200 Watts
Duty Cycle: 30 A continuous, 45 A for 1.5 seconds
Three Currents in Parallel
12 A 600 VA (848 peak) / 50.0 V RMS
50 A 600 VA (848 peak) / 13.4 V RMS
90 A 600 VA (848 peak) / 6.67 V RMS
135 A 900 VA (1272 peak) / 6.67 V RMS
Two Currents in Series
Compliance voltage doubles: 4.0 A at 100 V RMS up to 30 A at 13 V RMS
PowerV™ Voltage Amplifier
Flat power curve 30–150 V in 150 V range, enabling testing of high current and electromechanical relays requiring higher power.
AC/DC AUX Voltage Channel
AC Ranges 30 V (100 VA / 3.33 A), 150 V (100 VA / 0.67 A)
DC Ranges 30 V (100 W / 3.33 A), 250 V (100 W / 0.4 A)
Function Variable AC voltage source (polarizing/synchronizing) or DC battery simulator
AC Voltage Output
Output Voltage 0–300 V AC/DC (3 voltage sources + 1 AUX channel)
Ranges 30 V (150 VA / 5 A), 150 V (150 VA / variable), 300 V (150 VA / 0.5 A), DC 150 W
Duty Cycle Continuous
Phase Angle
Range 0.00–359.99° (CW or CCW) or 0.00 to ±180.00°
Accuracy ±0.02° typical, ±0.25° max at 50/60 Hz
Frequency
Range DC to 1000.000 Hz (variable)
Transient Playback DC to 10 kHz (COMTRADE compatible)
Resolution 0.001 Hz
Accuracy 2.5 ppm typical; 25 ppm (0–50 °C) at 50/60 Hz; AUX: 250 ppm
Metering
Displays AC/DC volts, amps, time, phase angle, frequency, Ohms, Watts, VA, and power factor. Accuracies apply from 10–100% of range at 50/60 Hz.
Accuracy (Measurement Channels)
AC Voltage ±0.05% reading + 0.02% range typical; ±0.15% + 0.05% max
DC Voltage 0.1% typical; 0.25% maximum
AC Current ±0.05% reading + 0.02% range typical; ±0.15% + 0.05% max
DC Current ±0.05% reading + 0.02% typical; ±0.15% + 0.05% max
Total Harmonic Distortion <0.1% typical, 2% max at 50/60 Hz
Timer
Range Seconds: 0.0001–99999.9 (Auto), Cycles: 0.01–99999.9 (Auto)
Accuracy ±0.001% reading typical, ±2 LSD, ±0.005% (0–50 °C)
Binary Inputs
Channels Up to 10 independent isolated inputs
Function Start/Stop/Monitor Gate; programmable logic trigger for output sequences
Input Rating Up to 300 V AC/DC
Binary Output Relays
High Current Outputs (1–4) AC: 400 V max, 8 A, 2000 VA; DC: 300 V max, 8 A, 80 W; Response <10 ms
High Speed Outputs (5–6) 400 V peak, 1 A max; Response <1 ms
Waveform Storage
Storage Capacity 256,000 samples per channel
Playback End-to-end triggered playback via external GPS synchronization
Protection
Voltage Outputs Short circuit and overload protected
Current Outputs Open circuit and overload protected
DC IN Inputs (Optional Transducer Feature)
DC IN Voltage 0 to ±10 V DC; Accuracy ±0.001% + 0.005% range typical; Resolution 0.001
DC IN Current 0–±1 mA or 4–±20 mA DC; Accuracy ±0.001% + 0.005% typical; Resolution 0.001
Environmental
Operating Temperature 0 to 50 °C (32 to 122 °F)
Storage Temperature -25 to 70 °C (-13 to 158 °F)
Relative Humidity 5–90% RH, non-condensing
Conformance Standards
Safety EN 61010-1
Shock EN/IEC 60068-2-27
Vibration EN/IEC 68-2-6
Transit Drop ISTA 1A
Free Fall EN/IEC 60068-2-32
Drop / Topple EN/IEC 60068-2-31
Electromagnetic Compatibility
Emissions EN 61326-2-1, EN 61000-3-2/3, FCC Subpart B Part 15 Class A
Immunity EN 61000-4-2/3/4/5/6/8/11
Physical
Weight 13.2 kg (29.35 lb) – 3-phase system
Dimensions 337 W × 172 H × 273 D mm (13.25 W × 6.75 H × 10.75 D in)
Enclosure & Transit Cases
Rugged metal field enclosure. Optional soft and hard transit cases available. Soft-sided case provides moderate protection against rain, dust, vibration, and shock. Hard-sided case ensures maximum protection during transport.