Megger SVERKER 780 relay and substation test system
Megger SVERKER 780 is a versatile relay and substation test system offering precise current, voltage, and timing measurements for protection testing.
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Megger SVERKER 780 – Protection Relay and Substation Test System
The Megger SVERKER 780 is an advanced secondary injection test system designed for comprehensive testing of protective relays, circuit breakers, and substation equipment. Building on the proven reliability of the SVERKER series, the 780 model offers enhanced functionality, high output capability, and intuitive operation, making it a trusted tool for power utilities, service companies, and industrial maintenance teams.
Megger SVERKER780 Key Features
-
Powerful Test Capabilities: Provides multiple current and voltage outputs for thorough testing of protection schemes.
-
Multi-Function Instrument: Timer, ammeter, voltmeter, and phase angle measurement integrated into one compact unit.
-
Flexible Operation: Suitable for testing electromechanical, static, and microprocessor-based relays.
-
High Accuracy: Delivers precise results in current, voltage, impedance, power, and phase angle measurements.
-
User-Friendly Interface: Equipped with a clear LCD display, multilingual support, and intuitive controls.
-
Durability: Rugged design with IP54 protection and wide operating temperature range, ideal for field environments.
-
Compliance: Meets international standards including EN 61010 for safety and IEC 61326 for EMC.
Megger SVERKER 780 Applications
-
Secondary injection testing of protection relays.
-
Verification of circuit breaker tripping and reclosing functions.
-
Testing impedance, power factor, and phase angle of substation systems.
-
Commissioning and maintenance of power system protection schemes.
-
Training and simulation in relay testing and fault analysis.
Specifications
Environment
| Application Field | Intended for use in high-voltage substations and industrial environments |
| Operating Temperature | 0 °C to +50 °C (32 °F to +122 °F) |
| Storage & Transport | -40 °C to +70 °C (-40 °F to +158 °F) |
| Humidity | 5% – 95% RH, non-condensing |
| CE Marking | LVD Directive 2006/95/EC, EMC Directive 2004/108/EC |
General
| Mains Voltage | 115/230 V AC, 50/60 Hz |
| Power Consumption (max) | 1380 W |
| Protection | Thermal cut-outs, automatic overload protection |
Dimensions
| Instrument | 350 × 270 × 220 mm (13.8” × 10.6” × 8.7”) |
| Transport Case | 610 × 350 × 275 mm (24.0” × 13.8” × 10.8”) |
Weight
| SVERKER 750 | 17.3 kg (38.1 lbs); 26.3 kg (58 lbs) with accessories and transport case |
| SVERKER 780 | 18.1 kg (39.9 lbs); 27.1 kg (59.7 lbs) with accessories and transport case |
Test Leads
| Stackable Safety Plugs | 2 × 0.25 m (2.5 mm²), 2 × 0.5 m (2.5 mm²), 8 × 2.0 m (2.5 mm²) |
| Spade Tongue Connectors | 2 × 3.0 m (10 mm²) |
Display & Languages
| Display | LCD |
| Available Languages | Czech, English, French, German, Spanish, Swedish, Turkish |
Timer
| Range | Resolution | Inaccuracy |
|---|---|---|
| 0 – 9.999 s | 1 ms | ±(1 ms + 0.01%) |
| 10.00 – 99.99 s | 10 ms | ±(10 ms + 0.01%) |
| 100.0 – 999.9 s | 100 ms | ±(100 ms + 0.01%) |
| 0.0 – 999.9 cycles | 0.1 cycles | ±(0.1 cycles + 0.01%) |
| 1000 – 49999 cycles at 50 Hz 1000 – 59999 cycles at 60 Hz |
1 cycle | ±(1 cycle + 0.01%) |
Ammeter
| Measurement Method | AC true RMS, DC mean value |
| Ranges | Internal: 0.00 – 250.0 A External: 0.000 – 6.000 A |
| Inaccuracy (Internal) | 0–10 A AC ±(1% + 20 mA) 0–40 A AC ±(1% + 40 mA) 0–100 A AC ±(1% + 200 mA) |
| Inaccuracy (External) | 0–0.6 A AC ±(1% + 20 mA) 0–6 A AC ±(1% + 20 mA) 0–0.6 A DC ±(0.5% + 2 mA) 0–6 A DC ±(0.5% + 20 mA) |
| Resolution | Internal: 10 mA (<100 A), 100 mA (>100 A) External: 1 mA |
Voltmeter
| Measurement Method | AC true RMS, DC mean value |
| Range | 0.00 – 600.0 V |
| Inaccuracy | AC ±(1% + 200 mV) max DC ±(0.5% + 200 mV) max |
Extra Measurements
| Measurement | Range | Resolution | Inaccuracy |
|---|---|---|---|
| Power Factor cos φ | -0.99 (cap) to +0.99 (ind) | 0.01 | ±0.04 |
| Phase Angle φ | 0 – 359° | 1° | ±2° |
Other: Impedance and power (Z, R, X, P, S, Q for AC; R and P for DC)
Make/Break Contact
| Max Current | 1 A |
| Max Voltage | 250 V AC or 120 V DC |
Reclosing Test
| Items Measured | Tripping and reclosing times |
| Display | List of all times after test |
| Breaker State Feedback | Make/Break contact can be used to feed back breaker state |
| Max Reclosings | 49 |
| Max Testing Time | 999 s |
Sets of Resistors and Capacitor
| Resistors | 0.5 Ω to 2.5 kΩ |
| Capacitor | 10 μF, max voltage 450 V AC |