Call for price
  • Accurate air data test set for precision measurement
  • ±(0.005% of reading) from 40% to 100% FS
  • ±(0.005% of 40%) from 0% to 40% FS
  • Stability: Absolute Over 3 months: 0.0019% RDG/3 months
  • Zeroing vacuum sensor: Absolute ±10 mtorr at 100 mtorr
  • Control stability: Absolute ±10 mTorr (1.33 Pa) @ 100 mTorr
  • Rate of climb: Absolute 0 to 1,829 m/min (0 to 6,000 ft/min)
  • Total Uncertainty (Aeronautical: 32 in Hg a Sea level ±9 m (3ft)
(0)
Call for price
  • Select from a wide range of standard pressure ranges, including 5 to 1500 psig and 15 to 50 psia.
  • Optional modes include absolute and negative gauge.
  • High precision and stability ensure accurate measurements.
  • RS232 and IEEE-488 communication options.
  • ISO-17025 accredited calibration available.
  • Menu languages include English, French, Chinese, German, Japanese, Spanish, and Italian.
  • Barometric and vacuum reference options available.
(0)
Call for price
  • Automated pressure controller and calibrator for precise control and calibration of pressure systems.
  • High accuracy and reliability for industrial and laboratory applications.
  • Wide range of control precision and turndown options.
  • Easy interface and communication options.
  • Compact and rugged design for harsh environments.
  • ISO/IEC 17025 accreditation for calibration.
  • Supports interconnection of multiple systems.
(0)
Call for price
  • Compact HART communicator for field device configuration and diagnostics
  • Supports HART 4, 5, 6, and 7 protocols
  • Bluetooth v2.0 connectivity for remote access
  • Long-lasting rechargeable Li-Ion battery
  • IP67-rated for harsh environments
  • Compact design for easy handling
  • High-strength ABS plastic enclosure
  • Mini-Grabber HART cable connectors
(0)
Call for price
  • 4.5 digit class multimeter
  • Multi-unit sync
  • Fast settling time
  • Isolated terminal block
  • Scope output options
  • Impedance measurement
  • Input overload protection
(0)
Call for price
  • Flow measurement rate: 340 milliseconds
  • Flow ranges: 5000 slm
  • Communication ports: RS-232 (COM1), RS-232 (COM2), IEEE-488.2
  • Weight: 6.8 kg (15 lb) max
  • Dimensions (WxHxD): 32 cm x 12 cm x 30 cm (12.6 in x 4.7 in x 11.8 in) approx.
  • General Power requirements: 85 V ac to 264 V ac, 47 Hz to 440 Hz, 18 VA max consumption
  • Normal operating temperature range: 15 °C to 30 °C (59 °F to 86 °F)
(0)
Call for price
  • Accurate measurement of laminar flow
  • Used with molbox1+ and molbox2 terminals
  • High precision and stability
  • Wide range of applications
  • Calibrated to ensure accuracy
  • Easy to integrate into existing systems
  • Reliable performance in harsh environments
(0)
Call for price
  • High-precision current shunts for accurate measurements
  • Available in various shunt values from 1 mA to 100 A
  • Compact design with Type-N and Type-LC connectors
  • Compliant with 17025 accreditation for calibration
  • Wide operating temperature and humidity range
  • Long-term stability and accuracy
(0)
Call for price
  • Accurate AC/DC transfer standard for precise measurements
  • Wide range of applications, including calibration and testing
  • Highly reliable and durable design
  • Compliant with various industry standards
  • Easy to use and maintain
  • Compact and lightweight design
  • Long-term stability and accuracy
(0)
Call for price
  • High-accuracy DC voltage reference standards for precise measurements
  • Temperature range: 15 °C to 35 °C
  • Relative humidity: 0% to 90%
  • Altitude: 0 m to 1830 m
  • Non-specified operation: 0 °C to 50 °C
  • Storage: -40 °C to 50 °C
  • Long battery life and low power consumption
(0)
Call for price
  • AC and DC voltage measurement standard
  • 99% best accuracy, ±24 ppm absolute specification
  • 600 µV to 1000 V input range
  • RS-232 and IEEE-488 remote interfaces
  • Enhanced absolute accuracy to ±0.23% of voltage
  • Compliant with UL1244 and IEC 348-1976 safety standards
  • Compact 17.8 cm x 43.2 cm x 62 cm design
(0)
Call for price
  • High-precision Kelvin-Varley divider for precise voltage measurements
  • Seven decades of resolution with 0.1 ppm accuracy
  • Ratio range: 0 to 1.0 (1.0 input tap) and 0 to 1.1 (1.1 input tap)
  • Compact design for easy integration into test and measurement systems
  • Reliable performance in a wide range of applications
  • Meets the needs of technicians and engineers requiring high-accuracy voltage measurements
  • Backed by the quality and reliability of Fluke
(0)
Call for price
  • High-accuracy reference divider for precise voltage measurements
  • 10:1 and 100:1 ratio ranges
  • Excellent for applications in electrical engineering and research
  • Meets IEC 348 and ANSI-C39.5 safety standards
  • Compact and durable design
  • Comes with calibration documentation
(0)
Call for price
  • 12 values from 1Ω to 19 MΩ in x1 and x1.9
  • Best 1 Year Specification
  • Operating Temperature: 18-28°C
  • Storage Temperature: 0-40°C
  • Retrace Error (hysteresis): Negligible resistance shift
  • Size: 8.6 cm H x 10.5 cm W x 12.7 cm D
  • Weight: 0.68 kg to 0.91 kg
(0)
Call for price
  • High-precision calibrator for DC and AC voltage, resistance, and current measurements
  • Wideband AC voltage option for frequencies up to 50 MHz
  • IEEE-488, RS-232, USB 2.0, and Ethernet interfaces
  • Compact design with standard rack width and depth
  • Operating temperature range of 15°C to 35°C
  • Compliant with IEC 61010-1 and IEC 61326-1 safety standards
(0)
Call for price
  • High-performance amplifier for precise measurements
  • Accurate and reliable results
  • Designed for demanding applications
  • Compact and rugged construction
  • Easy to use and maintain
  • Meets the needs of professionals
  • Enhances productivity and efficiency
(0)
Call for price
  • High-accuracy transconductance amplifier for precise current measurements.
  • Wide input current range: 200 mA, 200 mA, 120 mA (100 mA dc).
  • Current gain: 10, 100, 1000.
  • Input voltage range: 2 V, 2 V, 1.2 V (1.0 V dc).
  • Transconductance: 1, 10, 100 Siemens.
  • Frequency: To 10 kHz.
  • Maximum output compliance voltage: 4.5 Vrms (6.4 Vpeak).
(0)
Call for price
  • Fluke 9500C is a high-performance oscilloscope calibrator designed for precision measurements.
  • It offers a range of features, including ACV, DCV, and edge measurements.
  • The calibrator also features a leveled sine frequency range of 0.1 Hz to 4.2 GHz.
  • It has a leveled sine amplitude range of 0.1 Hz to 2.1 GHz.
  • The calibrator also features a marker function with up to 1 p-p accuracy.
  • It has a pulse width range of 1 to 100 nS.
  • The calibrator also features resistance and capacitance measurement capabilities.
(0)
Call for price
  • Electrical safety testing and calibration for technicians and engineers
  • Meets IEC 61010-1 and IEC 61010-2-030 standards
  • Confidence level: 99%
  • Specifications interval: 1 year
  • Power line: 115/230 V ac (50/60 Hz)
  • Power consumption: 1250 VA maximum
  • Fuse protection: AC mains input, RCD input, Meter amps input, Loop/Line impedance input, Leakage current input
(0)
Call for price
  • RS-232 and IEEE-488 (GPIB) interface for seamless connectivity
  • Operating temperature range: 18°C to 28°C
  • Storage temperature range: -20°C to 70°C
  • Compliant with EN61326 and EN/IEC 61010-1:2010 safety standards
  • Compact dimensions: 44.5 cm x 29.8 cm x 17.5 in
  • Weighs 4.24 kg (9.35 lb)
  • Power consumption: 15 VA maximum
(0)
Call for price
  • 8.5-digit resolution for precise measurements
  • DC voltage: 100 mV – 1000 V
  • AC voltage: 10 mV – 1000 V, 1 Hz – 10 MHz
  • Resistance: 1 Ω – 10 GΩ
  • DC current: 10 uA – 2 A
  • AC current: 10 uA – 2A, 1 Hz to 100 kHz
  • Digitize V: 100 mV – 1000 V, 5 MSamples/s, up to 20 MHz BW
  • Digitize I: 10 uA – 2 A, 5 MSamples/s, up to 4 MHz BW
(0)
Call for price
  • Advanced wire tracing technology for precise location of energized and de-energized wires
  • Measures up to 600 V CAT III voltage
  • Operates at 6.25 kHz frequency
  • Features numeric bar graph display and audible beep
  • Tip sensor response time: 500 ms
  • Max distance via air: up to 20 ft (6.1 m)
(0)
Call for price
  • Accurate underground utility location with Amprobe UAT-610
  • Active and passive tracing modes
  • Depth measurement and accuracy up to 20 ft 4 in
  • IP54 water and dust resistance
  • 35 hours battery life
  • Compact and lightweight design
  • Meets IEC and CSA safety standards
(0)
Call for price
  • Advanced wire tracing kit for professionals
  • CAT III 600 V measurement category
  • 0 to 600 V AC/DC operating voltage
  • 6.25 kHz energized and 32.768 kHz de-energized operating frequency
  • Hazardous voltage detection and numeric signal indications
  • 500 ms response time and 5-second battery voltage monitoring
  • Up to 20 ft range detection and pinpointing