Rated 0 out of 5
(0)
- Measures bypass diode comparator judgment
- Tests bypass route resistor
- Checks open-circuit voltage
- Measures short-circuit current
- Applies measurement current
- Tests crystal system strings
- Ensures rated current
- Monitors measurement accuracy
Rated 0 out of 5
(0)
- High-accuracy measurements with ±0.15% rdg. ±2 dgt. basic accuracy
- True RMS measurements for AC voltage and current
- Wide range of functions including continuity check, diode test, and harmonic levels
- Compact and lightweight design for easy handling
- USB and wireless communication options for data transfer
- Long battery life with auto-power save function
Rated 0 out of 5
(0)
- High-precision DC voltmeter with 5 ranges and ±0.0009% basic accuracy.
- Wide measurement range from 100 mV to 1000 V.
- Integration time unit in PLC/ms and ms settings.
- Measurement support functions including smoothing, null, and temperature compensation.
- Management support functions including comparator, BIN, and label display.
- Interfaces including LAN, EXT. I/O, and USB flash drive.
- Power supply of 100 to 240 V AC, 50/60 Hz, 30 VA.
Rated 0 out of 5
(0)
- DC Voltage: 100 mV ( ±120.000 00 mV) to 1000 V ( ±1000.000 0 V ), 5 ranges
- Basic accuracy: 10 V range: ±0.0009% rdg. ±12 μV
- Temperature: -10.0°C to 60.0°C (14.0°F to 140°F), combined with sensor Z2001: ±0.5°C (5.0°C to 35°C)
- Integration time: 1 ms to 9999 ms
- Measurement support functions: Smoothing function, null, temperature compensation, scaling, over-range display, self-calibration, auto-hold, contact check
- Management support functions: Comparator, BIN, absolute value judgment, label display, statistics, measurement information, communication monitor, EXT. I/O TEST
- Contact check: Check signal: 10 mV rms, threshold value: 0.5 nF to 50 nF (Cannot use in the 100 V/1000 V ranges), Contact check integration time: 1 ms to 100 ms
- Interfaces: Standard: LAN (100BASE-TX), EXT. I/O, USB flash drive / USB device (USB2.0 Full-Speed) Optional: GP-IB (-02 type only) / RS-232C (-03 type only) / PRINTER (-03 type only)
- Power supply: 100 to 240 V AC, 50/60 Hz, 30 VA
- Dimensions and mass: 215 mm (8.46 in) W × 88 mm (3.46 in) H × 232 mm (9.13 in) D (-01 type): 2.3 kg (81.1 oz), (-02/-03 type): 2.4 kg (84.7 oz)
- Included accessories: Instruction manual ×1, power cord ×1
Rated 0 out of 5
(0)
- High-accuracy DC voltage measurement with 5 ranges and ±0.0009% rdg. ±12 μV basic accuracy
- Temperature range of -10.0°C to 60.0°C (14.0°F to 140°F)
- Integration time unit: PLC/ms (PLC setting: 0.02/ 0.2/ 1/ 10/ 100, ms setting: 1 ms to 9999 ms)
- Measurement support functions including Smoothing function, null, temperature compensation, scaling, over-range display, self-calibration, auto-hold, contact check
- Management support functions including Comparator, BIN, absolute value judgment, label display, statistics, measurement information, communication monitor, EXT. I/O TEST
- Interfaces including LAN (100BASE-TX), EXT. I/O, USB flash drive / USB device (USB2.0 Full-Speed)
- Power supply of 100 to 240 V AC, 50/60 Hz, 30 VA
- Dimensions and mass of 215 mm (8.46 in) W × 88 mm (3.46 in) H × 232 mm (9.13 in) D and 2.3 kg (81.1 oz)
Rated 0 out of 5
(0)
- High-precision DC voltage measurement with 5 ranges.
- Basic accuracy of ±0.0020% rdg. ±12 μV on 10 V range.
- Temperature range of -10.0°C to 60.0°C (14.0°F to 140°F).
- Integration time unit: PLC/ms with 5 settings.
- Measurement support functions including smoothing, null, and temperature compensation.
- Management support functions including comparator, BIN, and absolute value judgment.
- Interfaces include LAN, EXT. I/O, and USB with optional GP-IB, RS-232C, and PRINTER.
Rated 0 out of 5
(0)
- High-accuracy DC voltage measurement with 5 ranges.
- Basic accuracy of ±0.0020% rdg. ±12 μV.
- Temperature range of -10.0°C to 60.0°C (14.0°F to 140°F).
- Integration time of 0.02/ 0.2/ 1/ 10/ 100 PLC/ms or 1 ms to 9999 ms.
- Measurement support functions including smoothing, null, and temperature compensation.
- Management support functions including comparator, BIN, and label display.
- Interfaces including LAN, EXT. I/O, and USB.
Rated 0 out of 5
(0)
- High-accuracy DC voltage measurement with 5 ranges
- Basic accuracy of ±0.0020% rdg. ±12 μV on 10 V range
- Temperature range of -10.0°C to 60.0°C (14.0°F to 140°F)
- Integration time unit: PLC/ms with 5 settings
- Measurement support functions including smoothing, null, and temperature compensation
- Management support functions including comparator, BIN, and label display
- Interfaces including LAN, EXT. I/O, and USB
Rated 0 out of 5
(0)
- Accurate measurements with Hioki Clamp Meters
- Wide range of applications in electrical and industrial settings
- Reliable and durable design for long-lasting performance
- Easy to use and navigate
- Compact and lightweight for increased portability
- Advanced features for enhanced functionality
- Compliance with international standards
- Warranty and support from MME
Rated 0 out of 5
(0)
- Rated input current: 5000 A AC/ 500 A AC Max.
- Max. allowable input: 10000 A continuous (45 to 66 Hz, requires derating at frequency)
- Bandwidth: 10 Hz to 20 kHz (±3dB)
- Amplitude and phase accuracy: ±2 % rdg. ±0.3 % f.s. (45 to 66 Hz, at center of flexible loop)
- Phase: ±1 deg (45 to 66 Hz)
- Output voltage: 500 mV AC/f.s. (0.1 mV AC/A) at 5000 A range 500 mV AC/f.s. (1 mV AC/A) at 500 A range
- Max. rated voltage to earth: 1000 V AC (CAT III), 600 V AC (CAT IV)
- Core diameter: φ 100 mm (3.94 in)
- Output terminal: BNC
- Operating temperature: -25 °C to +65 °C (-13 °F to 149 °F)
- Power supply: LR6 (AA) alkaline batteries ×2, Continuous use : 7 days (rated power 35 mVA), or AC adapter 9445-02/-03 (rated power 0.2 VA), or External power supply 5 to 15 V DC (rated power 0.2 VA)
- Dust and water resistance: Flexible loop only: IP54 * Do not use when wet.
- Dimensions and mass: Flexible loop cable diameter: φ7.4 mm (0.29 in), Cable length: Between flexible loop and battery box: 2 m (6.56 ft), Output cable: 1 m (3.28 ft), Battery box: 35 mm (1.38 in)W × 120.5 mm (4.74 in)H × 34 mm (1.34 in)D, 280 g (9.9 oz)
- Included accessories: LR6 (AA) alkaline batteries ×2, Instruction manual ×1
Rated 0 out of 5
(0)
- Connectable current sensors with a Hioki ME15W (male) output connector.
- Output Terminal: BNC Terminal.
- Output voltage: 2 V f.s.
- Total waveform output: 2 V f.s.
- Total RMS output: 2 V DC f.s.
- Operating temperature range: -10 °C to 50 °C (14 °F to 122 °F).
- Power supply: AC Adapter Z1002 (100 to 240 V AC, 50/60 Hz, maximum rated power when used with sensors: 155 VA).
Rated 0 out of 5
(0)
- Connectable current sensors with a Hioki ME15W (male) output connector
- Waveform output and RMS output can be used simultaneously
- Operating temperature range of -10°C to 50°C (14°F to 122°F)
- Power supply options: AC Adapter Z1008 or external power supply
- Dimensions: 33 mm (1.30 in)W × 67 mm (2.64 in)H × 132 mm (5.20 in)D
- Weight: 200 g (7.1 oz)
- Accessories included: AC Adapter Z1008, Power cord, Instruction manual
Rated 0 out of 5
(0)
- Connectable current sensors with a Hioki ME15W (male) output connector.
- Output Terminal: BNC Terminal.
- Output voltage: 2 V f.s.
- Output resistance: 50 Ω.
- Operating temperature range: -10°C to 50°C (14°F to 122°F).
- Power supply: AC Adapter Z1008 (100 to 240 V AC, 50/60 Hz, maximum rated power when used with sensors: 45 VA).
- Dimensions and mass: 33 mm (1.30 in)W × 67 mm (2.64 in)H × 132 mm (5.20 in)D (excluding protruding parts), 200 g (7.1 oz).
- Included accessories: AC Adapter Z1008 ×1, Power cord ×1, Instruction manual ×1.
Rated 0 out of 5
(0)
- Rated measurement current: 2000 A AC/DC
- Max. measurement current: 2000 A (requires derating at frequency)
- Max. allowable peak input: 2840 A peak
- Bandwidth: DC to 5 kHz (-3dB)
- Typical phase accuracy: ±2.3 deg. (DC < f ≤ 66 Hz)
- Output rate: 0.1 mV/A
- Max. rated voltage to earth: AC/DC 600 V (CAT IV) AC/DC 1000 V (CAT III)
- Core diameter: φ 55 mm (2.17 in) or less
- Output connectors: HIOKI PL 14
- Operating temperature range: -25°C to 65°C (-13°F to 149°F)
- Dimensions and mass: 64 mm (2.52 in)W × 195 mm (7.68 in)H × 34 mm (1.34 in)D, 510 g (18.0 oz), Cable length 2.5 m (8.20 ft)
Rated 0 out of 5
(0)
- Rated measurement current: 600 A AC/DC
- Max. measurement current: 600 A (requires derating at frequency)
- Max. allowable peak input: 900 A peak
- Bandwidth: DC to 5 kHz (-3dB)
- Typical phase accuracy: ±1.8 deg. (DC < f ≤ 66 Hz)
- Output rate: 1 mV/A
- Max. rated voltage to earth: AC/DC 600 V (CAT IV) AC/DC 1000 V (CAT III)
- Core diameter: φ 33 mm (1.30 in) or less
- Output connectors: HIOKI PL 14
- Operating temperature range: -25°C to 65°C (-13°F to 149°F)
- Dimensions and mass: 64 mm (2.52 in)W × 160 mm (6.30 in)H × 34 mm (1.34 in)D, 320 g (11.3 oz), Cable length 2.5 m (8.20 ft)
Rated 0 out of 5
(0)
- Rated measurement current: 100 A AC/DC
- Max. measurement current: 100 A (requires derating at frequency)
- Max. allowable peak input: 150 A peak
- Bandwidth: DC to 5 kHz (-3dB)
- Typical phase accuracy: ±1.8 deg. (DC < f ≤ 66 Hz)
- Output rate: 1 mV/A
- Max. rated voltage to earth: AC/DC 600 V (CAT IV)
- Core diameter: φ 33 mm (1.30 in) or less
- Output connectors: HIOKI PL 14
Rated 0 out of 5
(0)
- Rated measurement current: 2000 A AC/DC
- Max. measurement current: 2000 A (requires derating at frequency)
- Max. allowable peak input: 2840 A peak
- Bandwidth: DC to 10 kHz (-3dB)
- Typical phase accuracy: ±2.3 deg. (DC < f ≤ 66 Hz)
- Output rate: 0.1 mV/A
- Max. rated voltage to earth: AC/DC 600 V (CAT IV) AC/DC 1000 V (CAT III)
- Core diameter: φ 55 mm (2.17 in) or less
- Output connectors: HIOKI PL 14
- Operating temperature range: -25°C to 65°C (-13°F to 149°F)
- Dimensions and mass: 64 mm (2.52 in)W × 195 mm (7.68 in)H × 34 mm (1.34 in)D, 510 g (18.0 oz), Cable length 2.5 m (8.20 ft)
Rated 0 out of 5
(0)
- Accurate measurement of AC/DC currents up to 600 A.
- Wide bandwidth of DC to 10 kHz (-3dB).
- High accuracy of ±1.8 deg. (DC < f ≤ 66 Hz).
- Compact design with φ 33 mm (1.30 in) or less core diameter.
- High safety rating of AC/DC 600 V (CAT IV) and AC/DC 1000 V (CAT III).
- Easy installation with HIOKI PL 14 output connectors.
- Wide operating temperature range of -25°C to 65°C (-13°F to 149°F).
Rated 0 out of 5
(0)
- Rated measurement current: 100 A AC/DC
- Max. measurement current: 100 A (requires derating at frequency)
- Max. allowable peak input: 150 A peak
- Bandwidth: DC to 10 kHz (-3dB)
- Typical phase accuracy: ±1.8 deg (DC < f ≤ 66 Hz)
- Output rate: 1 mV/A
- Max. rated voltage to earth: AC/DC 600 V (CAT IV)
- Core diameter: φ 33 mm (1.30 in) or less
- Output connectors: HIOKI PL 14
- Operating temperature range: -25°C to 65°C (-13°F to 149°F)
- Dimensions and mass: 58 mm (2.28 in)W × 132 mm (5.20 in)H × 18mm (0.71 in)D, 250 g (8.8 oz), Cable length 2.5 m (8.20 ft)
Rated 0 out of 5
(0)
- Measures up to 6000 A AC with high accuracy
- Flexible loop cable diameter of φ7.4 mm (0.29 in)
- IP54 dust and water resistance for reliable measurements
- Operating temperature range of -25°C to 65°C (-13°F to 149°F)
- Compact battery box dimensions of 25 mm (0.98 in)W × 72 mm (2.83 in)H × 20 mm (0.79 in)D
- Max. allowable input of 10000 A continuous
- Bandwidth of 10 Hz to 50 kHz (±3dB)
- Output rate of 1 mV/A (600 A*) or 0.1 mV/A (6000 A)
Rated 0 out of 5
(0)
- High-accuracy AC/DC current measurement
- Wide frequency bandwidth
- Compact design
- Long cable length
- Multiple accessories included
- Wide operating temperature range
- High-quality construction
- Easy to use
Rated 0 out of 5
(0)
- Rated current: 500 A AC/DC
- Max. allowable input: Within the derating range, however, up to ±1000 A peak is allowable if within 20 ms.
- Frequency bandwidth: Amplitude: DC to 4 MHz (CT6904A), DC to 2 MHz (CT6904A-1)
- Linearity: ±5 ppm Typical (23°C (73°F))
- Offset voltage: ±10 ppm Typical (23°C (73°F), no input)
- Basic accuracy: DC (Amplitude: ±0.025 % rdg. ±0.007 % f.s., No phase specification)
- Output voltage rate: 4 mV / A rated
- Max. rated voltage to earth: 1000 V CAT III
- Core diameter: φ 32 mm (1.26 in.)
Rated 0 out of 5
(0)
- High accuracy clamp meter accessory for precise AC/DC current measurements.
- Wide frequency bandwidth for DC to 4 MHz (CT6904A) or DC to 2 MHz (CT6904A-1).
- Compact design with a core diameter of φ 32 mm (1.26 in.)
- Operating temperature range of -10°C to 50°C (14°F to 122°F).
- Power supply from compatible Hioki power analyzers, sensor units, or current units.
- Max. rated power of 7 VA Max. (500 A/55 Hz measurement, with a power supply of ±12 V).
- Dimensions and mass of 139 mm (5.47 in.) W × 120 mm (4.72 in.) H × 52 mm (2.05 in.) D.
Rated 0 out of 5
(0)
- High accuracy measurement of AC/DC current up to 2000 A
- Wide frequency range from DC to 1 MHz
- Compact design with 3 m (9.84 ft) cable length
- Easy to use with included instruction manual
- Meets CAT III safety standards
- Power supplied via Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977
- Max. rated power 9.5 VA max. (at 2000 A/55 Hz, ±12 V power requirement)
Bench Multimeters