The Hioki 3288 20 Clamp On AC/DC HiTester is a versatile tool for measuring AC and DC current, voltage, resistance, and frequency.
- Measures AC current up to 1000A (average rectification)
- Operating temperature range: -25°C to 65°C
- Slim clamp core design for use in confined spaces
- Optional flexible sensor support for complex wiring
- Measures AC/DC voltage and resistance
- Drop resistance tested for 1-meter durability
Discover the Hioki 3481 for accurate voltage detection, ideal for professional electricians needing reliable performance.
The Hioki 3481 20 is a pen-style, non-metallic contact voltage detector with a bright LED light that promotes safety and work efficiency even in dim worksites.
Ensure precision with the Hioki RM3548 Resistance Meter, perfect for laboratory testing. Buy now for reliable measurements.
The Hioki 3030-10 Hitester ensures precise electronics testing with high accuracy and easy usability. Ideal for professionals and hobbyists alike.
Discover 1000V precision with the Hioki 3246-60 Hitester Pencil, perfect for electricians needing reliable performance.
Discover reliable accuracy with Hioki L9207-10 Test Lead, perfect for precise digital measurements. Ideal for professionals and test enthusiasts.
Experience precise measurements with the portable Hioki 3244-60 Card HiTester, ideal for on-the-go electrical testing.
Hioki DT4253 Digital Multimeter delivers high accuracy, ideal for professional measurements. Reliable and easy to use.
Hioki DT4252 Digital Multimeter delivers high accuracy for professional-grade measurements. Ideal for electricians.
The Hioki Dt4256 Digital Multimeter delivers 1000V precision for accurate electrical measurements. Perfect for professionals.
- High accuracy voltage measurement up to 5000 V rms
- Wide measurement range from DC to 4 MHz
- Compact design for easy installation
- Compliant with international safety standards
- Includes accessories for convenient use
- Reliable performance in harsh environments
- Wide operating temperature range from -10°C to 50°C
- Low power consumption with 100 V to 240 V AC power supply
- 4-channel digital voltmeter for DC voltage measurement
- Isolated BNC connectors with high input impedance
- High accuracy with ±0.02% rdg. ±0.0025% f.s.
- Compact design with dimensions 106 x 19.8 x 196.5 mm
- Lightweight with a mass of 250 g
- Wide measurement range with 1, 10, 100 V f.s., 3 ranges
- Fast measurement time with 20 ms × NPLC (during 50 Hz), 16.67 ms × NPLC (during 60 Hz)
- Accurate measurement of acceleration and voltage
- 2 channels for simultaneous measurement
- Input terminals for voltage and charge input
- Adaptive converter for optimal measurement
- Compact design with 230g weight
- IEEE 1451.1.4 class 1 compatible TEDS
- 16-bit A/D conversion for high measurement resolution
- 4-channel analog unit for voltage measurement
- Isolated BNC terminal with 1 MΩ input impedance and 30 pF input capacitance
- Measurement range of 100, 200, 400 mV f.s., 1, 2, 4, 10, 20, 40 V f.s., 9 ranges
- Low-pass filter options of 5/500/5 k/200 kHz
- Measurement resolution of 1/32000 of measurement range using 16 bit A/D conversion
- Highest sampling rate of 5 MS/s for 4-channel simultaneous sampling
- Measurement accuracy of ±0.3% f.s. with filter 5 Hz and zero position accuracy included
- 3-channel current measurement with optional current sensor
- Dedicated connector terminal (ME 15 W) with input resistance 1 MΩ
- Measurement range from 200 mA to 100000 A
- Measurement resolution of 1/32000 of measurement range
- Highest sampling rate of 5 MS/s (3 channel simultaneous sampling)
- Measurement accuracy of ±0.3% f.s. (with 5 Hz filter)
- Dimensions and mass of 106 mm (4.17 in.) W × 19.8 mm (0.78 in.) H × 196.5 mm (7.74 in.) D, 250 g (8.8 oz.)
- High-speed analog unit for precise measurements
- 2 channels for voltage measurement
- Isolated BNC terminal with 1 MΩ input impedance
- 1000 V AC or DC max. rated voltage to earth
- 12 measurement ranges, including 280 V rms for AC voltage
- 200 MS/s sampling rate and ±0.5% f.s. measurement accuracy
- DC to 30 MHz frequency characteristics
- Compact dimensions: 106 mm W × 19.8 mm H × 196.5 mm D, 280 g
- 4-channel analog unit for precise voltage measurement
- Isolated BNC terminals for safe and reliable connections
- High measurement accuracy of ±0.1% f.s.
- 5 MS/s sampling rate for fast data capture
- DC to 2 MHz frequency range for comprehensive measurements
- Compact design for easy integration into systems
- Reliable performance in harsh electrical environments
- High accuracy voltage measurement with 2 channels and DC/RMS selectable.
- Wide measurement range from 200 mV/div to 50 V/div (DC mode) and 500 mV/div to 50 V/div (RMS mode).
- High sampling rate of 1MS/s for precise data capture.
- Compact design with dimensions 106 mm W × 19.8 mm H × 196.5 mm D and weight 230 g.
- Meets CAT III and CAT IV safety standards for reliable electrical measurements.
- Ideal for electrical safety testing and measurement applications.
- High-quality construction ensures durability and long lifespan.
- Easy to use with intuitive interface and clear display.
- Measures strain gauge signals with high accuracy
- 2-channel measurement for distortion analysis
- NDIS connector for easy connection
- 30 V rms or 60 V DC rated voltage
- 6 measurement ranges for flexibility
- Low-pass filter for noise reduction
- 200 kS/s sampling rate for fast measurement
- 245 g compact design
- Output terminal: 8 channels, isolated
- Connector: 25-pin D-sub
- Max. rated voltage to earth: 25 V
- Output items: DC voltage, DC current, resistance (simulated output)
- Output range: DC voltage: -0.100 0 V to +5.300 0 V, DC current: 5 mA range: -5.000 0 mA to +5.000 0 mA
- Setting resolution: 0.1 mV, 0.1 μA, 0.01 μA, 0.001 μA
- Output accuracy: DC voltage: 5 V range, ±0.035% of setting ± 800 μV, DC current: 5 mA range: ±0.050% of setting ± 4.0 μA
- High-precision arbitrary waveform generation with 2 channels and SMB terminal.
- Wide output voltage range from -10 V to 15 V.
- DC, Sine wave, Square wave, Pulse wave, Triangular wave, Ramp wave function generator capabilities.
- Arbitrary waveform generator mode with waveforms measured by Memory Hicorders.
- 2 MHz D/A refresh rate for high-speed waveform generation.
- Program function with max. 128 steps and sweep function for frequency, amplitude, offset, and duty.
- Self-test function for voltage and external input/output control.
- Compact dimensions of 106 mm W × 19.8 mm H × 196.5 mm D and weight of 250 g.
- Connectable instruments: Memory HiLogger LR8450 (Designed for use with plug-in units only) and Memory HiLogger LR8450-01 (Wireless LAN model)
- Operating temperature and humidity: -10°C to 50°C, 80% RH or less (no condensation)
- Storage temperature and humidity: -20°C to 60°C, 80% RH or less (no condensation)
- Vibration resistance: JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent
- Number of input channels: 5 ch
- Measurement targets: Current (using an optional current sensor)
- Input format: Current sensor (Hioki PL14)
- Response time for instantaneous values: 150 μs
- Frequency characteristics for RMS values: DC to 5 kHz
- Response time for RMS values: 0.8 s
- Current measurement: 200 mA, 2 A (CT7812), 500 mA, 5 A (CT7116), 2 A, 20 A (CT7822), 5 A, 50 A (CT7126), 100 A (CT7131, CT7731), 50 A, 500 A (CT7136, CT7736), 200 A, 2000 A (CT7742), 50 A, 500 A, 5000 A (CT7044, CT7045, CT7046)