Fluke 123B/S Portable Industrial Oscilloscopes (20 MHz)
Short Description:
Include:
- Fluke 123B portable oscilloscope
- Shielded test leads with black ground leads
- Test lead, black (for grounding)
- Hook clamps (red, blue)
- Banana plug to BNC adapter (black, 1 piece)
- USB angle adapter
- WiFi USB adapter*
- Switching power supply, adapter/battery charger
- Li-ion battery pack
- Padded carry bag
- Magnetic hanging device
- ScopeMeter® software FlukeView® for Windows®
- Protective film
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
17
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 123BS Portable Industrial Oscilloscopes (20 MHz)
The Fluke 123B/S Industrial ScopeMeter is a compact, rugged handheld oscilloscope tailored for industrial electrical and electro-mechanical equipment troubleshooting and maintenance. It combines the functionalities of a dual-input digital oscilloscope and multimeter, offering a 20 MHz oscilloscope bandwidth. This instrument is designed to facilitate faster troubleshooting, thanks to features like Connect-and-Viewâ„¢ triggering and IntellaSetâ„¢ technology.
The former automatically displays stable waveforms without manual adjustment of amplitude, timebase, and trigger settings, while the latter analyzes the signal and automatically displays relevant numerical readings, making data interpretation more straightforward.
The Fluke 123B/S also features a dual-input waveform and meter reading recorder for extended data trending, along with a Recorder Event Detect function that captures elusive intermittent signals, enhancing its utility for complex industrial applications. It’s designed to withstand harsh environments, evidenced by its ability to endure 3g vibration, 30g shock, and its IP51 rating for dust and drip protection. It boasts the highest safety rating in the industry, CAT IV 600 V.
For more detailed specifications and applications, the Fluke 123B/S supports measurements like resistance, diode, continuity, capacitance, and power measurements, and it’s equipped with shielded test leads for various measurements. Its compatibility with the Fluke Connect mobile app enhances its utility by allowing for easy data sharing and analysis. The ScopeMeter is ideal for maintenance applications, where understanding signal characteristics and changes over time is crucial, and it can also assist in pinpointing intermittent faults efficiently​.
Fluke 123 BS Specifications:
Oscilloscope mode | ||
Vertical | ||
Frequency Response – DC coupled | without probes and measuring lines (with BB120) | 123B: DC to 20 MHz (-3 dB) 124B, 125B: DC to 40 MHz (-3 dB) |
with shielded 1:1 measuring cable pair STL120-IV | DC to 12.5 MHz (-3 dB) / DC to 20 MHz (-6 dB) | |
with 10:1 probe VP41 | 123B: DC to 20 MHz (-3 dB) 124B, 125B: DC to 40 MHz (-3 dB) |
|
Frequency Response – AC coupled (when ROLL mode off) | without probes and measuring lines | <10Hz (-3dB) |
with shielded 1:1 measuring cable pair STL120-IV | <10Hz (-3dB) | |
with 10:1 probe VP41 | <10Hz (-3dB) | |
Rise time, without probes or | 123B <17.5 ns 124B and 125B < 8.75 ns |
|
Input impedance | without probes and measuring lines | 1MΩ//20pF |
with BB120 | 1MΩ//24pF | |
with shielded 1:1 measuring cable pair STL120-IV | 1MΩ//230pF | |
with 10:1 probe VP41 | 5MΩ//15.5pF | |
sensitivity | 5 mV to 200 V/div | |
Analog bandwidth limiter | 10kHz | |
Display modes | A, -A, B, -B | |
Max. input voltage A and B | directly, with measuring cables or VP41 probe | CAT IV 600 Veff |
with BB120 | 600 Veff | |
Max. floating voltage, from each connection to ground | CAT IV 600 Veff | |
Horizontal | ||
Oscilloscope modes | Normal, Single, Roll mode | |
Areas (Normal) | Sampling of repetitive signals | 123B: 20ns to 500ns/Div, |
124B and 125B: 10ns to 500ns/div | ||
Real-time sampling | 1 µs to 5 s/div | |
Single (real time) | 1 µs to 5 s/div | |
Roll mode (real time) | 1 s to 60 s/div | |
Sample rate (for both inputs simultaneously) | Sampling rate (both channels, repeating signals) | up to 4 GS/s |
Real-time sampling 1 s to 60 s/div. | 40MS/s |
Triggering | ||
Display update | Free running when triggered | |
source | AWAY | |
Sensitivity A and B | at DC up to 5 MHz | 0.5 divisions or 5 mV |
at 40MHz | 123B: 4 Div | |
124B and 125B: 1.5 div | ||
at 60MHz | 123B: N/A | |
124B and 125B: 4 Div | ||
Flank | Rising, Falling |
Additional oscilloscope functions | ||
Display modes | Normal | Detects glitches (short disturbance pulses) up to 25 ns and displays an analogue-like afterglow signal form |
smoothing | Removes noise from a waveform | |
Glitch capture off | Does not capture glitches between sample points | |
Envelope | Records and displays the minimum and maximum values ​​of waveforms over time | |
Auto Set (Connect-and-View™) | Constant fully automatic adjustment of amplitude, time base, trigger level, trigger distance and delay time. Manual deactivation by user setting of amplitude, time base or trigger level. |
Probe accuracy +1%. There must be at least one waveform period visible on the display.
Dual channel multimeter | ||
The accuracy of all measurements is between 18 °C and 28 °C within ± (% of the measured value + counting steps of the least significant digit). | ||
Add 0.1 x (specified accuracy) for each °C below 18°C ​​or above 28°C. For voltage measurements with a 10:1 probe, add them together |
Entrance A and Entrance B | ||
DC voltage (VDC) | ||
areas | 500mV, 5V, 50V, 500V, 750V | |
accuracy | ±(0.5% + 5) | |
Common Mode Rejection (CMRR) | >100 dB at DC, >60 dB at 50, 60 or 400 Hz | |
Display scope | 5,000 counting steps | |
True RMS voltage values ​​(V AC ​​and V AC+DC) | ||
areas | 500mV, 5V, 50V, 500V, 750V | |
Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V AC+DC) | ±(1% + 10) |
1Hz to 60Hz (VAC) | ±(1% + 10) | |
Accuracy for 5% to 100% of range (AC or DC coupled) | 60Hz to 20kHz | ±(2.5% + 15) |
DC suppression (VAC only) | >50dB | |
Common Mode Rejection (CMRR) | >100 dB at DC | |
>60 dB at 50, 60, or 400 Hz | ||
Display scope | 5000 counting steps, measured value is independent of the crest factor. | |
peak value | ||
Display types | Max Peak, Min Peak, or Peak to Peak | |
areas | 500mV, 5V, 50V, 500V, 2200V | |
accuracy | Max Peak or Min Peak | 5% of the range end value |
Accuracy peak to peak | 10% of the range end value | |
Display scope | 500 counting steps | |
Frequency (Hz) | ||
areas | 123B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz, and 50MHz | |
124B and 125B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz and 70MHz | ||
Frequency range | 15 Hz (1 Hz) to 50 MHz with continuous automatic adjustment | |
Accuracy at 1 Hz to 1 MHz | ±(0.5% + 2) | |
Display scope | Display size up to 10,000 | |
revolutions/min. (RPM or min-1) | ||
Maximum value | 50,000 rpm | |
accuracy | ±(0.5% + 2) | |
duty cycle | ||
Area | 2% to 98% | |
Frequency range | 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment | |
Pulse width | ||
Frequency range | 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment | |
Display scope | 1000 counting steps | |
Current strength | ||
with current clamp | areas | such as V DC, V AC, V AC+DC or peak value |
Scaling factors | 0.1mV/A, 1mV/A, 10mV/A, 100mV/A, 400mV/A, 1V/A, 10mV/mA | |
accuracy | as with V DC, V AC, V AC+DC, or PEAK (the inaccuracy of the current clamp must be added) | |
Temperature with optional temperature sensor | ||
Area | 200°C/div (200°F/div) | |
Scaling factor | 1mV/°C and 1mV/°F | |
accuracy | as with V DC (the inaccuracy of the temperature sensor must be added) | |
Decibel (dB) | ||
0dBV | 1V | |
0dBm (600Ω /50Ω) | 1 mW related to 600 Ω or 50 Ω | |
dB for | V DC, V AC or V AC+DC | |
Display scope | 1000 counting steps | |
Crest factor | ||
Area | 1 to 10 | |
Display scope | 90 counting steps | |
phase | ||
Types of measurement | A to B, B to A | |
Area | 0 to 359 degrees | |
resolution | 1 degree | |
Power (125B only) | ||
Configurations | 1-phase or 3-phase with symmetrical load (3-phase: only fundamental component, only AUTOSET operation) | |
Power factor (PF) | Ratio between active power and apparent power: 0.00 to 1.00 | |
Active power (watts) | RMS measurements of corresponding samples from input A (voltage) and input B (current) | |
Display scope | 999 counting steps | |
Apparent power (VA) | V eff x A eff | |
Display scope | 999 counting steps | |
Reactive power (VAR) | √((VA)²-W²) | |
Display scope | 999 counting steps | |
Vpwm | ||
Purpose | For measuring pulse width modulated signals, e.g. B. at the outputs of frequency converters | |
principle | Measurements show the effective voltage based on the average of sample points over a range of periods of the fundamental frequency | |
accuracy | as with Veff for sine signals |
Entrance A | ||
Resistance (Ω) | ||
areas | 123B and 124B | 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ |
125B | 50Ω, 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ | |
accuracy | ± (0.6% + 5), in the range 50 Ω ±(2% + 20) | |
Display scope | 50 Ω to 5 MΩ – 5000 counts, 30 MΩ – 3000 counts | |
measuring current | 0.5 mA to 50 nA, decreasing with larger ranges | |
Open circuit voltage | <4V | |
Continuity test | ||
Acoustic signal | <(30 Ω ± 5 Ω) in the 50 Ω range | |
measuring current | 0.5mA | |
Detection of short circuits | ≥1 ms | |
Diode test | ||
Measuring voltage: | at 0.5 mA | >2.8V |
at idle | <4V | |
measuring current | 0.5mA | |
polarity | + at input A, – at COM | |
capacity | ||
areas | 50nF, 500nF, 5μF, 50μF, 500μF | |
Display scope | 5,000 counting steps | |
measuring current | 500 nA to 0.5 mA, increasing with larger ranges |
Advanced multimeter functions | ||
Zero Set | Setting the actual value as a reference value | |
AutoHold (at A) | Captures a stable measurement result and fixes it on the display. If the measurement result is stable, an acoustic signal sounds. The AutoHold function affects the main measurement display, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals. | |
Fixed decimal point | Activated by pressing the attenuator buttons |
Include:
- Fluke 123B portable oscilloscope
- Shielded test leads with black ground leads
- Test lead, black (for grounding)
- Hook clamps (red, blue)
- Banana plug to BNC adapter (black, 1 piece)
- USB angle adapter
- WiFi USB adapter*
- Switching power supply, adapter/battery charger
- Li-ion battery pack
- Padded carry bag
- Magnetic hanging device
- ScopeMeter® software FlukeView® for Windows®
- Protective film
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Fluke 123B/S Portable Industrial Oscilloscopes (20 MHz)” Cancel reply
You must be logged in to post a review.
Related Products
GW Instek GDS 2104A Digital Storage Oscilloscope, 100MHz, 4 Channel
Rated 0 out of 5
In stock
AED 6,287 (excl.VAT)
GW Instek GDS 2102A Digital Storage Oscilloscope, 100MHz, 2 Channel
Rated 0 out of 5
In stock
AED 6,285 (excl.VAT)
gw instek gds1104b digital storage oscilloscope
Rated 5.00 out of 5
In stock
Reviews
Clear filtersThere are no reviews yet.