Fluke 123B/S Portable Industrial Oscilloscopes (20 MHz)

Short Description:

Include:

  • Fluke 123B portable oscilloscope
  • Shielded test leads with black ground leads
  • Test lead, black (for grounding)
  • Hook clamps (red, blue)
  • Banana plug to BNC adapter (black, 1 piece)
  • USB angle adapter
  • WiFi USB adapter*
  • Switching power supply, adapter/battery charger
  • Li-ion battery pack
  • Padded carry bag
  • Magnetic hanging device
  • ScopeMeter® software FlukeView® for Windows®
  • Protective film

Product purchase

SKU: 77668 Category:
Brand:Fluke

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

17 People watching this product now!

Terms of sending goods ›

  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

Fluke 123BS Portable Industrial Oscilloscopes (20 MHz)

The Fluke 123B/S Industrial ScopeMeter is a compact, rugged handheld oscilloscope tailored for industrial electrical and electro-mechanical equipment troubleshooting and maintenance. It combines the functionalities of a dual-input digital oscilloscope and multimeter, offering a 20 MHz oscilloscope bandwidth. This instrument is designed to facilitate faster troubleshooting, thanks to features like Connect-and-Viewâ„¢ triggering and IntellaSetâ„¢ technology.

The former automatically displays stable waveforms without manual adjustment of amplitude, timebase, and trigger settings, while the latter analyzes the signal and automatically displays relevant numerical readings, making data interpretation more straightforward.

The Fluke 123B/S also features a dual-input waveform and meter reading recorder for extended data trending, along with a Recorder Event Detect function that captures elusive intermittent signals, enhancing its utility for complex industrial applications. It’s designed to withstand harsh environments, evidenced by its ability to endure 3g vibration, 30g shock, and its IP51 rating for dust and drip protection. It boasts the highest safety rating in the industry, CAT IV 600 V.

For more detailed specifications and applications, the Fluke 123B/S supports measurements like resistance, diode, continuity, capacitance, and power measurements, and it’s equipped with shielded test leads for various measurements. Its compatibility with the Fluke Connect mobile app enhances its utility by allowing for easy data sharing and analysis. The ScopeMeter is ideal for maintenance applications, where understanding signal characteristics and changes over time is crucial, and it can also assist in pinpointing intermittent faults efficiently​.

Fluke 123 BS Specifications:

Oscilloscope mode
Vertical
Frequency Response – DC coupled without probes and measuring lines (with BB120) 123B: DC to 20 MHz (-3 dB)
124B, 125B: DC to 40 MHz (-3 dB)
with shielded 1:1 measuring cable pair STL120-IV DC to 12.5 MHz (-3 dB) / DC to 20 MHz (-6 dB)
with 10:1 probe VP41 123B: DC to 20 MHz (-3 dB)
124B, 125B: DC to 40 MHz (-3 dB)
Frequency Response – AC coupled (when ROLL mode off) without probes and measuring lines <10Hz (-3dB)
with shielded 1:1 measuring cable pair STL120-IV <10Hz (-3dB)
with 10:1 probe VP41 <10Hz (-3dB)
Rise time, without probes or 123B <17.5 ns
124B and 125B < 8.75 ns
Input impedance without probes and measuring lines 1MΩ//20pF
with BB120 1MΩ//24pF
with shielded 1:1 measuring cable pair STL120-IV 1MΩ//230pF
with 10:1 probe VP41 5MΩ//15.5pF
sensitivity 5 mV to 200 V/div
Analog bandwidth limiter 10kHz
Display modes A, -A, B, -B
Max. input voltage A and B directly, with measuring cables or VP41 probe CAT IV 600 Veff
with BB120 600 Veff
Max. floating voltage, from each connection to ground CAT IV 600 Veff
Horizontal
Oscilloscope modes Normal, Single, Roll mode
Areas (Normal) Sampling of repetitive signals 123B: 20ns to 500ns/Div,
124B and 125B: 10ns to 500ns/div
Real-time sampling 1 µs to 5 s/div
Single (real time) 1 µs to 5 s/div
Roll mode (real time) 1 s to 60 s/div
Sample rate (for both inputs simultaneously) Sampling rate (both channels, repeating signals) up to 4 GS/s
Real-time sampling 1 s to 60 s/div. 40MS/s

 

Triggering
Display update Free running when triggered
source AWAY
Sensitivity A and B at DC up to 5 MHz 0.5 divisions or 5 mV
at 40MHz 123B: 4 Div
124B and 125B: 1.5 div
at 60MHz 123B: N/A
124B and 125B: 4 Div
Flank Rising, Falling

 

Additional oscilloscope functions
Display modes Normal Detects glitches (short disturbance pulses) up to 25 ns and displays an analogue-like afterglow signal form
smoothing Removes noise from a waveform
Glitch capture off Does not capture glitches between sample points
Envelope Records and displays the minimum and maximum values ​​of waveforms over time
Auto Set (Connect-and-View™) Constant fully automatic adjustment of amplitude, time base, trigger level, trigger distance and delay time. Manual deactivation by user setting of amplitude, time base or trigger level.

Probe accuracy +1%. There must be at least one waveform period visible on the display.

Dual channel multimeter
The accuracy of all measurements is between 18 °C and 28 °C within ± (% of the measured value + counting steps of the least significant digit).
Add 0.1 x (specified accuracy) for each °C below 18°C ​​or above 28°C. For voltage measurements with a 10:1 probe, add them together

 

Entrance A and Entrance B
DC voltage (VDC)
areas 500mV, 5V, 50V, 500V, 750V
accuracy ±(0.5% + 5)
Common Mode Rejection (CMRR) >100 dB at DC, >60 dB at 50, 60 or 400 Hz
Display scope 5,000 counting steps
True RMS voltage values ​​(V AC ​​and V AC+DC)
areas 500mV, 5V, 50V, 500V, 750V
Accuracy for 5% to 100% of range (DC coupled) DC to 60 Hz (V AC+DC) ±(1% + 10)
1Hz to 60Hz (VAC) ±(1% + 10)
Accuracy for 5% to 100% of range (AC or DC coupled) 60Hz to 20kHz ±(2.5% + 15)
DC suppression (VAC only) >50dB
Common Mode Rejection (CMRR) >100 dB at DC
>60 dB at 50, 60, or 400 Hz
Display scope 5000 counting steps, measured value is independent of the crest factor.
peak value
Display types Max Peak, Min Peak, or Peak to Peak
areas 500mV, 5V, 50V, 500V, 2200V
accuracy Max Peak or Min Peak 5% of the range end value
Accuracy peak to peak 10% of the range end value
Display scope 500 counting steps
Frequency (Hz)
areas 123B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz, and 50MHz
124B and 125B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz and 70MHz
Frequency range 15 Hz (1 Hz) to 50 MHz with continuous automatic adjustment
Accuracy at 1 Hz to 1 MHz ±(0.5% + 2)
Display scope Display size up to 10,000
revolutions/min. (RPM or min-1)
Maximum value 50,000 rpm
accuracy ±(0.5% + 2)
duty cycle
Area 2% to 98%
Frequency range 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment
Pulse width
Frequency range 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment
Display scope 1000 counting steps
Current strength
with current clamp areas such as V DC, V AC, V AC+DC or peak value
Scaling factors 0.1mV/A, 1mV/A, 10mV/A, 100mV/A, 400mV/A, 1V/A, 10mV/mA
accuracy as with V DC, V AC, V AC+DC, or PEAK (the inaccuracy of the current clamp must be added)
Temperature with optional temperature sensor
Area 200°C/div (200°F/div)
Scaling factor 1mV/°C and 1mV/°F
accuracy as with V DC (the inaccuracy of the temperature sensor must be added)
Decibel (dB)
0dBV 1V
0dBm (600Ω /50Ω) 1 mW related to 600 Ω or 50 Ω
dB for V DC, V AC or V AC+DC
Display scope 1000 counting steps
Crest factor
Area 1 to 10
Display scope 90 counting steps
phase
Types of measurement A to B, B to A
Area 0 to 359 degrees
resolution 1 degree
Power (125B only)
Configurations 1-phase or 3-phase with symmetrical load (3-phase: only fundamental component, only AUTOSET operation)
Power factor (PF) Ratio between active power and apparent power: 0.00 to 1.00
Active power (watts) RMS measurements of corresponding samples from input A (voltage) and input B (current)
Display scope 999 counting steps
Apparent power (VA) V eff x A eff
Display scope 999 counting steps
Reactive power (VAR) √((VA)²-W²)
Display scope 999 counting steps
Vpwm
Purpose For measuring pulse width modulated signals, e.g. B. at the outputs of frequency converters
principle Measurements show the effective voltage based on the average of sample points over a range of periods of the fundamental frequency
accuracy as with Veff for sine signals

 

Entrance A
Resistance (Ω)
areas 123B and 124B 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ
125B 50Ω, 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ
accuracy ± (0.6% + 5), in the range 50 Ω ±(2% + 20)
Display scope 50 Ω to 5 MΩ – 5000 counts, 30 MΩ – 3000 counts
measuring current 0.5 mA to 50 nA, decreasing with larger ranges
Open circuit voltage <4V
Continuity test
Acoustic signal <(30 Ω ± 5 Ω) in the 50 Ω range
measuring current 0.5mA
Detection of short circuits ≥1 ms
Diode test
Measuring voltage: at 0.5 mA >2.8V
at idle <4V
measuring current 0.5mA
polarity + at input A, – at COM
capacity
areas 50nF, 500nF, 5μF, 50μF, 500μF
Display scope 5,000 counting steps
measuring current 500 nA to 0.5 mA, increasing with larger ranges

 

Advanced multimeter functions
Zero Set Setting the actual value as a reference value
AutoHold (at A) Captures a stable measurement result and fixes it on the display. If the measurement result is stable, an acoustic signal sounds. The AutoHold function affects the main measurement display, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal point Activated by pressing the attenuator buttons

Include:

  • Fluke 123B portable oscilloscope
  • Shielded test leads with black ground leads
  • Test lead, black (for grounding)
  • Hook clamps (red, blue)
  • Banana plug to BNC adapter (black, 1 piece)
  • USB angle adapter
  • WiFi USB adapter*
  • Switching power supply, adapter/battery charger
  • Li-ion battery pack
  • Padded carry bag
  • Magnetic hanging device
  • ScopeMeter® software FlukeView® for Windows®
  • Protective film

Datasheet

Mme-Pdfs-Image

0 reviews
0
0
0
0
0

There are no reviews yet.