Fluke 125B/S Handheld Digital Oscilloscope (40 MHz)

Short Description:

Product purchase
SKU: 77655 Category:
Brand:Fluke

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

18 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

Fluke 125BS Digital Oscilloscope (40 MHz)

The Fluke 125B/S Industrial ScopeMeter® is a robust and versatile handheld oscilloscope tailored for troubleshooting and maintenance applications in industrial electrical and electro-mechanical equipment. This model integrates the functionalities of an oscilloscope, multimeter, and high-speed recorder, providing a comprehensive test tool in a single compact device.

The 125 B/S model is distinguished by its 40 MHz oscilloscope bandwidth and includes advanced features like Connect-and-Viewâ„¢ trigger simplicity, which offers hands-off operation by automatically displaying stable waveforms without the need for manual adjustments. Additionally, it features IntellaSetâ„¢ technology, which intelligently adjusts numerical readouts based on the measured signal, enhancing the efficiency and accuracy of troubleshooting tasks.

Fluke 125 B/S ScopeMeter

This ScopeMeter® also supports the Fluke Connect mobile app and FlukeView® for ScopeMeter software, allowing for enhanced collaboration, data analysis, and archiving of critical test information. It is designed to withstand harsh industrial environments, evidenced by its high safety rating for CAT IV 600 V and a rugged design that can withstand vibration, shock, and is rated IP51 for dust and drip-proof protection. The device operates on a Li-Ion rechargeable battery, ensuring up to seven hours of operation, making it suitable for extended use in the field.

For industrial applications, the fluke 125B/S can perform a variety of measurements including voltage, current, power waveforms, harmonics, resistance, diode, continuity, and capacitance measurements. It is equipped with capabilities for power measurements (W, VA, VAR, PF, DPF, Hz) and harmonics analysis, providing a comprehensive understanding of the electrical health of loads. The model also features an industrial Bus Health Test, verifying electrical signal quality on industrial buses and networks, which is crucial for ensuring the reliability and efficiency of industrial systems.

With its combination of durability, precision, and advanced features, the Fluke 125B/S Industrial ScopeMeter® is well-suited for professionals seeking a reliable tool for industrial maintenance and troubleshooting applications​.

Fluke 125B/S Specifications:

Oscilloscope mode
Vertical
Frequency Response – DC coupled without probes and measuring lines (with BB120) 123B: DC to 20 MHz (-3 dB)
124B, 125B: DC to 40 MHz (-3 dB)
with shielded 1:1 measuring cable pair STL120-IV DC to 12.5 MHz (-3 dB) / DC to 20 MHz (-6 dB)
with 10:1 probe VP41 123B: DC to 20 MHz (-3 dB)
124B, 125B: DC to 40 MHz (-3 dB)
Frequency Response – AC coupled (when ROLL mode off) without probes and measuring lines <10Hz (-3dB)
with shielded 1:1 measuring cable pair STL120-IV <10Hz (-3dB)
with 10:1 probe VP41 <10Hz (-3dB)
Rise time, without probes or 123B <17.5 ns
124B and 125B < 8.75 ns
Input impedance without probes and measuring lines 1MΩ//20pF
with BB120 1MΩ//24pF
with shielded 1:1 measuring cable pair STL120-IV 1MΩ//230pF
with 10:1 probe VP41 5MΩ//15.5pF
sensitivity 5 mV to 200 V/div
Analog bandwidth limiter 10kHz
Display modes A, -A, B, -B
Max. input voltage A and B directly, with measuring cables or VP41 probe CAT IV 600 Veff
with BB120 600 Veff
Max. floating voltage, from each connection to ground CAT IV 600 Veff
Horizontal
Oscilloscope modes Normal, Single, Roll mode
Areas (Normal) Sampling of repetitive signals 123B: 20ns to 500ns/Div,
124B and 125B: 10ns to 500ns/div
Real-time sampling 1 µs to 5 s/div
Single (real time) 1 µs to 5 s/div
Roll mode (real time) 1 s to 60 s/div
Sample rate (for both inputs simultaneously) Sampling rate (both channels, repeating signals) up to 4 GS/s
Real-time sampling 1 s to 60 s/div. 40MS/s

 

Triggering
Display update Free running when triggered
source AWAY
Sensitivity A and B at DC up to 5 MHz 0.5 divisions or 5 mV
at 40MHz 123B: 4 Div
124B and 125B: 1.5 div
at 60MHz 123B: N/A
124B and 125B: 4 Div
Flank Rising, Falling

 

Additional oscilloscope functions
Display modes Normal Detects glitches (short disturbance pulses) up to 25 ns and displays an analogue-like afterglow signal form
smoothing Removes noise from a waveform
Glitch capture off Does not capture glitches between sample points
Envelope Records and displays the minimum and maximum values ​​of waveforms over time
Auto Set (Connect-and-View™) Constant fully automatic adjustment of amplitude, time base, trigger level, trigger distance and delay time. Manual deactivation by user setting of amplitude, time base or trigger level.

Probe accuracy +1%. There must be at least one waveform period visible on the display.

Dual channel multimeter
The accuracy of all measurements is between 18 °C and 28 °C within ± (% of the measured value + counting steps of the least significant digit).
Add 0.1 x (specified accuracy) for each °C below 18°C ​​or above 28°C. For voltage measurements with a 10:1 probe, add them together

 

Entrance A and Entrance B
DC voltage (VDC)
areas 500mV, 5V, 50V, 500V, 750V
accuracy ±(0.5% + 5)
Common Mode Rejection (CMRR) >100 dB at DC, >60 dB at 50, 60 or 400 Hz
Display scope 5,000 counting steps
True RMS voltage values ​​(V AC ​​and V AC+DC)
areas 500mV, 5V, 50V, 500V, 750V
Accuracy for 5% to 100% of range (DC coupled) DC to 60 Hz (V AC+DC) ±(1% + 10)
1Hz to 60Hz (VAC) ±(1% + 10)
Accuracy for 5% to 100% of range (AC or DC coupled) 60Hz to 20kHz ±(2.5% + 15)
DC suppression (VAC only) >50dB
Common Mode Rejection (CMRR) >100 dB at DC
>60 dB at 50, 60, or 400 Hz
Display scope 5000 counting steps, measured value is independent of the crest factor.
peak value
Display types Max Peak, Min Peak, or Peak to Peak
areas 500mV, 5V, 50V, 500V, 2200V
accuracy Max Peak or Min Peak 5% of the range end value
Accuracy peak to peak 10% of the range end value
Display scope 500 counting steps
Frequency (Hz)
areas 123B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz, and 50MHz
124B and 125B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz and 70MHz
Frequency range 15 Hz (1 Hz) to 50 MHz with continuous automatic adjustment
Accuracy at 1 Hz to 1 MHz ±(0.5% + 2)
Display scope Display size up to 10,000
revolutions/min. (RPM or min-1)
Maximum value 50,000 rpm
accuracy ±(0.5% + 2)
duty cycle
Area 2% to 98%
Frequency range 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment
Pulse width
Frequency range 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment
Display scope 1000 counting steps
Current strength
with current clamp areas such as V DC, V AC, V AC+DC or peak value
Scaling factors 0.1mV/A, 1mV/A, 10mV/A, 100mV/A, 400mV/A, 1V/A, 10mV/mA
accuracy as with V DC, V AC, V AC+DC, or PEAK (the inaccuracy of the current clamp must be added)
Temperature with optional temperature sensor
Area 200°C/div (200°F/div)
Scaling factor 1mV/°C and 1mV/°F
accuracy as with V DC (the inaccuracy of the temperature sensor must be added)
Decibel (dB)
0dBV 1V
0dBm (600Ω /50Ω) 1 mW related to 600 Ω or 50 Ω
dB for V DC, V AC or V AC+DC
Display scope 1000 counting steps
Crest factor
Area 1 to 10
Display scope 90 counting steps
phase
Types of measurement A to B, B to A
Area 0 to 359 degrees
resolution 1 degree
Power (125B only)
Configurations 1-phase or 3-phase with symmetrical load (3-phase: only fundamental component, only AUTOSET operation)
Power factor (PF) Ratio between active power and apparent power: 0.00 to 1.00
Active power (watts) RMS measurements of corresponding samples from input A (voltage) and input B (current)
Display scope 999 counting steps
Apparent power (VA) V eff x A eff
Display scope 999 counting steps
Reactive power (VAR) √((VA)²-W²)
Display scope 999 counting steps
Vpwm
Purpose For measuring pulse width modulated signals, e.g. B. at the outputs of frequency converters
principle Measurements show the effective voltage based on the average of sample points over a range of periods of the fundamental frequency
accuracy as with Veff for sine signals

 

Entrance A
Resistance (Ω)
areas 123B and 124B 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ
125B 50Ω, 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ
accuracy ± (0.6% + 5), in the range 50 Ω ±(2% + 20)
Display scope 50 Ω to 5 MΩ – 5000 counts, 30 MΩ – 3000 counts
measuring current 0.5 mA to 50 nA, decreasing with larger ranges
Open circuit voltage <4V
Continuity test
Acoustic signal <(30 Ω ± 5 Ω) in the 50 Ω range
measuring current 0.5mA
Detection of short circuits ≥1 ms
Diode test
Measuring voltage: at 0.5 mA >2.8V
at idle <4V
measuring current 0.5mA
polarity + at input A, – at COM
capacity
areas 50nF, 500nF, 5μF, 50μF, 500μF
Display scope 5,000 counting steps
measuring current 500 nA to 0.5 mA, increasing with larger ranges

 

Advanced multimeter functions
Zero Set Setting the actual value as a reference value
AutoHold (at A) Captures a stable measurement result and fixes it on the display. If the measurement result is stable, an acoustic signal sounds. The AutoHold function affects the main measurement display, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal point Activated by pressing the attenuator buttons

only possible in single-channel mode)

Cursor display (124B and 125B)
Sources AWAY
Single vertical line Average, minimum and maximum value display
Average, minimum and maximum values ​​as well as time since display start (in ROLL mode; measuring device in HOLD mode)
Minimum and maximum value as well as time since display start (in RECORDER mode; measuring device in HOLD mode)
Harmonic values ​​in POWER QUALITY mode.
Two vertical lines Display of peak-to-peak values, time interval and reciprocal time interval
Display of mean, minimum and maximum values ​​as well as time interval (in ROLL mode; measuring device in HOLD mode)
Two horizontal lines Display high, low and peak-to-peak values
Rise or fall time Transition time, 0% and 100% level (manual or automatic level adjustment; automatic level adjustment
accuracy See Oscilloscope Accuracy

 

recorder
The recorder captures measured values ​​in multimeter recorder mode or continuously captures sampling points of the waveforms in oscilloscope recorder mode. The information is stored in internal memory or on an optional SD card (on the 125B or 124B).
The results are displayed as a recorder plotting a graph of minimum and maximum values ​​of measurements over time, or as a waveform display showing all sample points acquired.
Measurements
Measuring speed Maximum 2 measurements/s
Record size (min., max., average) 2 million measured values ​​for 1 channel
Recording period 2 weeks
Maximum number of events 1024
Waveform recording
Maximum sampling rate 400,000 sampling points/s
Recording space internal memory 400 million sampling points
Recording period internal memory 15 minutes at 500 μs/div
11 hours at 20 ms/div
Recording space on the SD card 1.5 billion sample points
Recording period SD card 11 hours at 500 μs/div
14 days at 20 ms/div
Maximum number of events 64

(Fundamental oscillation 40 Hz to 70 Hz)

Power quality (125B only)
Metrics Active Power (W), Apparent Power (VA), Reactive Power (VAR), Power Factor, Shift Power Factor, Hz
Ranges for W, VA, VAR (Auto) 250W to 250MW, 625MW, 1.56GW
if selected: Total (% r) ±(2% + 6)
when selected: fundamental oscillation (% f) ±(4% + 4)
Displacement power factor (DPF) 0.00 to 1.00
Power factor (PF) 0.00 to 1.00, ±0.04
Frequency range 10.0Hz to 15.0kHz
40.0Hz to 70.0Hz
Number of harmonics DC up to 51st harmonic
Measured values/cursor display Veff, Aeff, Watt Each harmonic of a fundamental can be selected for individual display
Includes the frequency of the fundamental wave, the phase angle and the harmonic distortion (in A and W)

 

Testing physical parameters of industrial bus systems (Fluke 125B only)
Type subtype protocol
AS-i NEN-EN 50295
CAN ISO-11898
Interbus S RS-422 EIA-422
Modbus RS-232 RS-232/EIA-232
RS-485 RS-485/EIA-485
Foundation Fieldbus H1 61158 ,Type 1, 31.25 kbit
Profibus DP EIA-485
P.A 61158, type 1

7 hours with meter on (screen waveform and setting) (maximum size: 32 GB)
for Windows® (both optional)

Other specifications
Screen Type 14.5 cm (5.7″) active matrix color TFT
resolution 640×480 pixels
Waveform display Vertical 10 div. x 40 pixels
Horizontal 12 Div. x 40 pixels
Power supply External Via power supply BC430
Input voltage 10V DC to 21V DC
Energy intake 5W typical
Input port 5mm
Internal About battery pack BP290
Powered by battery Li-ion battery 10.8 V
Operating time 7 hours at 50% backlight brightness
Charging time 4 hours with the meter switched off,
Permissible ambient temperature 0 to 40°C during charging
Storage Internal memory can store 20 records MicroSD card, optional
Mechanical information Dimensions 259x132x55mm
Weight 1.4 kg, including battery pack
interface Optically isolated Transferring screenshots (bitmaps), settings and data
Via USB to PC Optically isolated USB cable OC4USB, uses FlukeView® software
WLAN adapter (optional) Quick transfer of screen copies (bitmaps), settings and data to PC/notebook, tablet, smartphone, etc. There is a USB port for connecting the WLAN dongle. For safety reasons, do not use this USB port with a cable.

Group 1, Class AIV, 750 Vrms up to 400 Hz

Environmental conditions
Environmental conditions MIL-PRF-28800F, Class 2
temperature Battery operation 0 to 40°C
Power supply operation 0 to 50°C
Storage at -20 to 60°C
Humidity (operation) at 0 to 10 °C Not condensing
at 10 to 30 °C 95%
at 30 to 40 °C 75%
at 40 to 50 °C 45%
Storage at at -20 to 60 °C Not condensing
Height Operating at 3,000 m CAT III 600V
Operating at 2,000 m CAT IV 600V
storage 12,000 m
Electromagnetic compatibility (EMC) International IEC 61326-1: Industrial, CISPR 11:
Korea (KCC) Class A Equipment (Industrial Broadcasting and Communications Equipment)
United States (FCC) 47 CFR 15, Subpart B. This product is exempt under clause 15.103.
Wireless radio transmission with WLAN adapter Frequency range 2412MHz to 2462MHz
Output power <100mW
IP protection rating of the housing IP 51, according to EN/IEC 60529
Security Generally IEC 61010-1: Pollution degree 2
Measurements IEC 61010-2-033: CAT IV 600V / CAT III 750V
Max. input voltage input A and B Directly at the input or with measuring lines 600 Vrms CAT IV for load reduction (derating)
With banana plug to BNC adapter BB120 600 Vrms for load reduction (derating)
Maximum floating voltage from each connection to ground 600 Vrms CAT

Include:

  • Fluke 125B portable oscilloscope
  • Shielded test leads with black ground leads
  • Test lead, black (for grounding)
  • Hook clamps (red, blue)
  • Banana plug to BNC adapter (black, 1 piece)
  • 10:1 voltage probe
  • AC current clamp i400S
  • USB angle adapter
  • WiFi USB adapter*
  • Switching power supply, adapter/battery charger
  • Li-ion battery pack
  • Padded carry bag
  • Magnetic hanging device
  • ScopeMeter® software FlukeView® for Windows®
  • Protective film

Datasheet

Mme-pdfs-image

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Fluke 125B/S Handheld Digital Oscilloscope (40 MHz)”